FUNCTION OF MAIN COMPONENTS


a.

The air conditioning system consists of the following parts:

Control Outline
Air Conditioning Amplifier Assembly Transmits and receives data to and from the switches and sensors, and controls the air conditioning system.
Blower Motor with Fan Sub-assembly Driven according to the target airflow volume calculated by the air conditioning amplifier assembly to blow air toward the cabin and circulate the air inside the cabin.
Servo Motors Controlled by the air conditioning amplifier assembly to move the mode control dampers and switch the registers, outlet air temperature and air inlet mode.
Water Heater (Electric Heater Sub-assembly) Driven according to air conditioning amplifier assembly and EV control ECU control, and warms the coolant.
Compressor with Motor Assembly Performs suction, compression and discharge of refrigerant gas.
Heater Water Pump (Water Pump with Motor Assembly) Controlled by the air conditioning amplifier assembly to flow the fc coolant to the air conditioning unit.
Three Way Valve (Water Valve Assembly) This is driven by signal of air conditioner amplifier assembly and changes a circuit circulating cooling water.
PTC Heater (Quick Heater Assembly) Consists of a Positive Temperature Coefficient (PTC) element, an aluminum fin and a brass plate.
Air Conditioning Control Assembly Allows operation and adjustment of the air conditioning via switches.
Multi-display Assembly Displays the settings screen.
Integration Control Sub-assembly Relays display image information from the audio head unit to the multi-display assembly.
Evaporator Fin Sensor (No. 1 Cooler Thermistor) Detects the temperature of the cool air past the cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Ambient Temperature Sensor (Thermistor Assembly) Detects the ambient temperature and outputs it to the air conditioning amplifier assembly.
Cooler Thermistor (Room Temp. Sensor) Detects the internal temperature inside the cabin and outputs that data to the air conditioning amplifier assembly.
Air Conditioner Pressure Sensor Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly.
Solar Sensor (Automatic Light Control Sensor) Detects the changes in the amount of solar energy and outputs them to the main body ECU (multiplex network body ECU).
Main Body ECU (Multiplex Network Body ECU)
·

Sends solar energy level difference, signals to the air conditioning amplifier assembly.

·

Door closing motion signaling is sent to air conditioner amplifier assembly.


EV Control ECU
·

Receives compressor operation signals and controls the compressor with motor assembly.

·

Detects the fc coolant temperature outputs the information to the air conditioning amplifier assembly.


Combination Meter Assembly Sends the vehicle speed signal to the air conditioning amplifier assembly.
Power Steering ECU with Motor Assembly Sends the loading control level signal to the air conditioning amplifier assembly.
DLC3
·

The Global TechStream (GTS) can be connected to read the Diagnostic Trouble Codes (DTCs) of malfunctions.

·

The Global TechStream (GTS) can be connected to change settings as desired by the user.





SYSTEM CONTROL


a.

The automatic air conditioning system uses the following controls:

Control Function
Neural Network Control This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain.
S-FLOW Control When the system judges that the rear doors have not been opened or closed while passengers are riding in the vehicle, the system automatically switches to front seat air outlet mode and begins operating according to the number of occupants and signals from each of the sensors.
Automatically switches to driver seat air outlet mode when the temperature and humidity inside the passenger compartment is stable while in front seat air outlet mode, or when the system judges that only the driver seat is occupied when the cooling or heating load is low.
HINT:

When all of the following conditions are met, the system judges that only the driver seat is occupied.

·

The passenger side door is closed.

·

The front passenger side mode setting switch and front passenger temperature setting switch is not operated.



Outlet Air Temperature Control Based on the temperature set by the temperature control switch, the neural network control calculates the outlet air temperature based on the input signals from various sensors.
The temperature setting for the driver and front passenger is controlled independently in order to provide a separate vehicle interior temperature for the right and left sides of the vehicle. As a result, air conditioning control that accommodates occupant preferences has been achieved.
Blower Control Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors.
Automatically increases the blower level when the defroster is on.
Air Outlet Control Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control based on the input signals from various sensors.
In accordance with the coolant temperature, outside air temperature, amount of sunlight, required blower, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to FOOT/DEF mode to prevent the windows from becoming fogged when the outside air temperature is low.
Odor Suppression Control When the air conditioning system is started, the compressor assembly with motor is operated with the blower off for approximately 6 seconds to cool the No. 1 cooler evaporator. As a result, the odor inside the air conditioning unit is adsorbed in the water that forms on the surface of the evaporator.
From approximately 6 to 11 seconds after the system is started, the air outlet mode is set to FOOT mode and the blower operates at low speeds to discharge the air inside the air conditioning unit into the footwell. From approximately 11 to 17 seconds after the system is started, the system returns to the previously set control mode. These controls prevent the air inside the air conditioning unit from blowing out toward the face area when the air conditioning system is started, reducing feelings of discomfort. Furthermore, delayed operation control timing for the blower can be changed using the customization function. For details, refer to the Repair Manual.
Air Inlet Control Automatically controls the air inlet control damper to achieve the calculated outlet air temperature that is required.
Drives the No. 1 blower damper servo sub-assembly (fresh/recirculation damper) in accordance with the operation of the air inlet control switch and moves the dampers to the FRESH or RECIRC position.
Compressor Control The air conditioning amplifier assembly calculates the target speed of the compressor based on the target evaporator temperature (which is calculated by the room temperature sensor, ambient temperature sensor and solar sensor) and the actual evaporator temperature that is detected by the evaporator temperature sensor in order to control the compressor speed.
The air conditioning amplifier assembly calculates the target evaporator temperature, which includes corrections based on the vehicle interior humidity (which is obtained from the humidity sensor), solar sensor, room temperature sensor, mode damper position, and wiper operation condition). Accordingly, the air conditioning amplifier assembly controls the compressor speed to an extent that would not inhibit the proper cooling performance or defogging performance.
Turns the air conditioning on automatically when the AUTO button is pressed when the blower is on and the air conditioning is off.
Decreases the compressor speed in order to ensure quietness when the vehicle is stopped.
Blower Customization Control The air volume can be adjusted to 3 levels using the FAST ECO switch on multi-display: NORMAL-ECO (small air volume)-FAST (large air volume)
Diagnosis A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system.


b.

Neural Network Control

i.

In the previous automatic air conditioning system, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with a calculation formula that had been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, but extremely uncomfortable in a hot climate. Therefore, as a technique for performing a high level of control, a neural network is used in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly, which performs control to provide enhanced air conditioning comfort.


ii.

The neural network control consists of neurons in an input layer, an intermediate layer, and an output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of this data is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor with fan sub-assembly in accordance with the control volumes that have been calculated by the neural network control.

Y128416E01
2.99,0.073 4.208,0.396 1.219,0.323 10 false Intermediate Layer 3.958,0.385 5.177,0.708 1.219,0.323 10 false Output Layer 2.396,0.385 3.615,0.708 1.219,0.323 10 false Input Layer 4.594,0.74 6.354,1.094 1.76,0.354 10 false Target Output Temperature 1.188,0.74 2.948,1.094 1.76,0.354 10 false Ambient Temperature 1.323,1.406 2.677,1.781 1.354,0.375 10 false Amount of Sunlight 1.333,2.01 2.688,2.385 1.354,0.375 10 false Room Temperature 2.677,3.125 3.177,3.438 0.5,0.313 10 false Control 0.313,4.083 1.448,4.427 1.135,0.344 10 false Input Processing 2.333,3.563 3.531,3.865 1.198,0.302 10 false Neural Networking 2.49,4.104 3.333,4.521 0.844,0.417 10 false Target Outlet Temperature 0.385,5.25 1.198,5.802 0.813,0.552 10 false Temperature Setting 0.375,6.51 1.208,6.823 0.833,0.313 10 false Sensor Input 0.385,7.583 1.219,7.896 0.833,0.313 10 false Switch Input 0.594,8.458 2.698,8.771 2.104,0.313 10 false : Neural network operation range 2.313,4.896 3.5,5.344 1.188,0.448 10 false Amount of Sunlight Correction 2.479,5.698 3.344,6.271 0.865,0.573 10 false Target Airflow Volume 2.51,6.531 3.313,6.823 0.802,0.292 10 false Outlet Mode 2.583,7.281 3.24,7.563 0.656,0.281 10 false Inlet Mode 2.531,7.823 3.375,8.104 0.844,0.281 10 false Compressor 3.969,4.583 5.24,5.052 1.271,0.469 10 false Temperature Control Correction 3.865,5.708 5.365,6.208 1.5,0.5 10 false Various Types of Airflow Volume Corrections 3.906,6.427 5.344,6.938 1.438,0.51 10 false Various Types of Mode Corrections 4.063,7.167 5.135,7.698 1.073,0.531 10 false Various Types of Corrections 5.792,4.094 6.927,4.438 1.135,0.344 10 false Output Correction 5.885,4.635 6.833,5.125 0.948,0.49 10 false Air Mix Control Damper 5.917,5.833 6.813,6.135 0.896,0.302 10 false Blower Motor 5.938,6.438 6.771,6.958 0.833,0.521 10 false Mode Control Damper 5.854,7.146 6.823,7.656 0.969,0.51 10 false Air Inlet Control Damper 5.958,7.875 6.802,8.156 0.844,0.281 10 false Compressor



c.

FC Heat-linked Control

·

When the FC coolant temperature is low, the electric coolant heater (electric heater sub-assembly) is used to increase the coolant temperature, and the coolant passes through the heater radiator unit. At this time, the warm water three-way valve (heater water valve assembly) opens and some of the FC coolant enters the heater circuit.

·

When the FC coolant reaches a certain temperature or higher, the heat generated when the FC stack assembly generates power is also used to restrict the power consumption of the electric coolant heater (electric heater sub-assembly) and maintain heating performance. At this time, the heater radiator unit sub-assembly side and FC stack assembly side of the warm water three-way valve (heater water valve assembly) open, and the heat generated from the FC stack assembly enters and passes through the circuit.

·

When the FC coolant reaches a high temperature when driving at high-speeds or similar conditions, the warm water three-way valve (heater water valve assembly) fully opens, the FC coolant temperature is fully drawn into the heater circuit, and the output of the coolant heater (electric heater sub-assembly) is stopped, which improves fuel efficiency.

Y268468E02
2.729,0.25 2.896,0.25 2.896,0.25 3.313,1 true 2.74,1.417 2.948,1.729 2.948,1.729 3.115,1.729 true 3.458,0.833 3.792,0.25 3.792,0.25 3.958,0.25 true 5.094,3.958 5.427,3.625 5.427,3.625 5.594,3.625 true 5.083,3.313 5.417,2.979 5.417,2.979 5.583,2.979 true 0.156,0.677 0.99,0.969 0.833,0.292 10 false Temperature 0.25,3 0.948,3.552 0.698,0.552 10 false Electricity Consumed for Heating 3.156,1.667 4.802,2.365 1.646,0.698 10 false Heater Water Temperature (w/o Heat-linked Control) 4.917,2.135 6.635,2.396 1.719,0.26 10 false During High Speed Driving 5.625,3.531 6.969,3.719 1.344,0.188 10 false w/ Heat-linked Control 0.083,4.406 1.615,4.656 1.531,0.25 10 false FC Coolant Temperature 3.49,4.417 4.448,4.813 0.958,0.396 10 false Medium 5.625,4.417 6.583,4.813 0.958,0.396 10 false High 2,4.417 2.958,4.813 0.958,0.396 10 false Low 5.635,2.885 6.979,3.073 1.344,0.188 10 false w/o Heat-linked Control 4,0.167 7.156,0.531 3.156,0.365 10 false Heater Water Temperature (w/ Heat-linked Control) 1.219,0.167 2.75,0.417 1.531,0.25 10 false FC Coolant Temperature

Coolant Flow (when FC Coolant Temperature is Low)
Y268469C01
2.917,4.583 2.75,4.583 2.75,4.583 2.25,4.083 true 4.167,4.583 4,4.583 4,4.583 3.5,4.083 true 6.167,4.167 5.75,4.583 5.75,4.583 5.583,4.583 true 1.917,4.583 1.75,4.583 1.75,4.583 1.333,4.167 true 3.406,2.698 3.917,2.698 true 3.417,2.063 3.917,2.063 true 3.385,1.417 3.917,1.417 true 5.083,1.25 4.917,1.25 4.917,1.25 4.5,0.833 true 5.125,1.177 5.438,1.333 0.313,0.156 10 false *1 3.969,1.354 7.156,1.552 3.188,0.198 10 false *2 1.969,4.521 2.344,4.813 0.375,0.292 10 false *5 0.625,3.927 7.156,4.115 6.531,0.188 10 false : *a 0.625,4.188 7.156,4.375 6.531,0.188 10 false : *b 0.625,4.438 7.156,4.625 6.531,0.188 10 false : *c 3.969,2 7.156,2.198 3.188,0.198 10 false *3 3.969,2.625 7.156,2.823 3.188,0.198 10 false *4 2.969,4.521 3.458,4.802 0.49,0.281 10 false *6 4.219,4.521 4.604,4.813 0.385,0.292 10 false *7 5.396,4.521 5.74,4.813 0.344,0.292 10 false *8 0.156,4.625 7.156,4.813 7,0.188 10 false *d
*1 Heater Radiator Unit Sub-assembly *2 Water Heater (Electric Heater Sub-assembly)
*3 Heater Water Pump (Water Pump with Motor Assembly) *4 Three Way Valve (Water Valve Assembly)
·

Heater Radiator Unit Sub-assembly Side: Open

·

FC Stack Assembly Side: Closed


*5 Radiator *6 FC Cooling Water Temperature Control Valve
*7 FC Cooling Water Pump *8 FC Stack Assembly
*a FC Coolant Flow (High Temperature) *b FC Coolant Flow (Medium)
*c FC Coolant Flow (Low Temperature) *d This illustration is an image.


Coolant Flow (when FC Coolant Temperature is Medium)
Y268470C01
2.917,4.583 2.75,4.583 2.75,4.583 2.25,4.083 true 4.167,4.583 4,4.583 4,4.583 3.5,4.083 true 6.167,4.167 5.75,4.583 5.75,4.583 5.583,4.583 true 1.917,4.583 1.75,4.583 1.75,4.583 1.333,4.167 true 3.406,2.698 3.917,2.698 true 3.417,2.063 3.917,2.063 true 3.385,1.417 3.917,1.417 true 5.083,1.25 4.917,1.25 4.917,1.25 4.5,0.833 true 5.125,1.177 5.438,1.333 0.313,0.156 10 false *1 3.969,1.354 7.156,1.552 3.188,0.198 10 false *2 1.969,4.521 2.344,4.813 0.375,0.292 10 false *5 0.625,4.198 7.156,4.385 6.531,0.188 10 false : *a 0.625,4.458 7.156,4.646 6.531,0.188 10 false : *b 3.969,2 7.156,2.198 3.188,0.198 10 false *3 3.969,2.625 7.156,2.823 3.188,0.198 10 false *4 2.969,4.521 3.458,4.802 0.49,0.281 10 false *6 4.219,4.521 4.604,4.813 0.385,0.292 10 false *7 5.396,4.521 5.74,4.813 0.344,0.292 10 false *8 0.156,4.625 7.156,4.813 7,0.188 10 false *c
*1 Heater Radiator Unit Sub-assembly *2 Water Heater (Electric Heater Sub-assembly)
*3 Heater Water Pump (Water Pump with Motor Assembly) *4 Three Way Valve (Water Valve Assembly)
·

Heater Radiator Unit Sub-assembly Side: Open

·

FC Stack Assembly Side: Open


*5 Radiator *6 FC Cooling Water Temperature Control Valve
*7 FC Cooling Water Pump *8 FC Stack Assembly
*a FC Coolant Flow (High Temperature) *b FC Coolant Flow (Medium)
*c This illustration is an image. - -


Coolant Flow (when FC Coolant Temperature is High)
Y268471C01
2.917,4.583 2.75,4.583 2.75,4.583 2.25,4.083 true 4.167,4.583 4,4.583 4,4.583 3.5,4.083 true 6.167,4.167 5.75,4.583 5.75,4.583 5.583,4.583 true 1.917,4.583 1.75,4.583 1.75,4.583 1.333,4.167 true 3.406,2.698 3.917,2.698 true 3.417,2.063 3.917,2.063 true 3.385,1.417 3.917,1.417 true 5.083,1.25 4.917,1.25 4.917,1.25 4.5,0.833 true 5.125,1.177 5.438,1.333 0.313,0.156 10 false *1 3.969,1.354 7.156,1.552 3.188,0.198 10 false *2 1.969,4.521 2.344,4.813 0.375,0.292 10 false *5 0.625,4.198 7.156,4.385 6.531,0.188 10 false : *a 0.625,4.458 7.156,4.646 6.531,0.188 10 false : *b 3.969,2 7.156,2.198 3.188,0.198 10 false *3 3.969,2.625 7.156,2.823 3.188,0.198 10 false *4 2.969,4.521 3.458,4.802 0.49,0.281 10 false *6 4.219,4.521 4.604,4.813 0.385,0.292 10 false *7 5.396,4.521 5.74,4.813 0.344,0.292 10 false *8 0.156,4.625 7.156,4.813 7,0.188 10 false *c
*1 Heater Radiator Unit Sub-assembly *2 Water Heater (Electric Heater Sub-assembly)
*3 Heater Water Pump (Water Pump with Motor Assembly) *4 Three Way Valve (Water Valve Assembly)
·

Heater Radiator Unit Sub-assembly Side: Close

·

FC Stack Assembly Side: Open


*5 Radiator *6 FC Cooling Water Temperature Control Valve
*7 FC Cooling Water Pump *8 FC Stack Assembly
*a FC Coolant Flow (High Temperature) *b FC Coolant Flow (Medium)
*c This illustration is an image. - -





DIAGNOSIS


a.

In order to make system inspections easier to perform, a diagnosis function is used in consideration of serviceability. The Diagnostic Trouble Codes (DTCs) of malfunctions can be read by connecting the Global TechStream (GTS). For details, refer to the Repair Manual.