HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DETAILS  NO. 1 COOLER EVAPORATOR  


CONSTRUCTION


a.

Ejector Cycle System (ECS) Type Evaporator

i.

The ECS type No. 1 cooler evaporator sub-assembly is composed of a tank, tubes and cooling fins. For the tubes, extrusion is used so that small passages are created, helping to achieve excellent heat transmission performance and to allow for a thinner design (38 mm (1.5 in)). In addition, reductions in the height and pitch of the fins and reductions in the thickness of the tubes are achieved, helping to promote heat transmission and to allow for thinner core materials. The result of this is a significant reduction in size and weight of the evaporator. Also, clean coat is used for the main body of the evaporator, helping to suppress development of bacteria, which may cause bad smells, and chrome-free surface treatment is used in consideration of the environment.


ii.

The ejector is positioned in the ECS type No. 1 cooler evaporator sub-assembly top tank. The flow of the refrigerant is divided into the upwind and downwind sections as it passes through the evaporator, allowing for the ejector cycle (EJECS II)*.

HINT:

*: Ejector cycle (EJECS II) is a registered trademark owned by DENSO Corporation.



iii.

An ejector storage tank is positioned on the upper portion of the evaporator to improve ejector performance efficiency.

Y222586C01
1.635,0.833 2.698,0.979 true 2.25,0.365 3.281,0.708 true 1.458,2.813 2.542,2.729 true 2.813,2.969 1.635,3.458 true 2.073,0.302 2.385,0.5 0.313,0.198 10 false *1 1.479,0.76 1.792,0.958 0.313,0.198 10 false *2 1.271,2.74 1.583,2.938 0.313,0.198 10 false *a 1.469,3.406 1.781,3.604 0.313,0.198 10 false *b
*1 Ejector Tank *2 Ejector
*a Top Tank *b Bottom Tank





OPERATION


a.

Ejector Cycle System (ECS) Type Cooler Evaporator

i.

Ejector Cycle System Operation

1.

In a conventional refrigerant cycle, liquid refrigerant gas is sent into the cooler evaporator using the cooler expansion valve, generating cold air. However, a rapid decrease in the refrigerant pressure forms swirls, causing energy loss.

2.

In this ejector cycle, the energy loss caused by the cooler expansion valve is utilized by the operation of the ejector that injects and expands a high-pressure refrigerant, reducing energy consumption.

Y102838E09
1.927,3.01 1.927,2.76 1.927,2.76 1.208,2.531 true 0.156,0.563 2.042,0.906 1.885,0.344 12 false Cooler Expansion Valve: 0.375,3.813 1.406,4.115 1.031,0.302 10 false Low-pressure 0.385,0.979 1.417,1.281 1.031,0.302 10 false High-pressure 1.438,3.073 2.688,3.667 1.25,0.594 10 false Energy loss caused by swirls 4.281,3.906 5.917,4.26 1.635,0.354 10 false No. 1 Cooler Evaporator Sub-assembly 4.75,2.229 6.094,2.656 1.344,0.427 10 false Compressor Assembly with Motor 4.115,1.344 5.938,1.708 1.823,0.365 10 false Cooler Condenser Assembly 0.052,0.031 2.688,0.448 2.635,0.417 12 false Conventional Refrigerant Cycle:

Y102839E12
4.51,1.729 4.219,1.729 4.219,1.729 4.021,1.26 true 4.417,1.719 4.01,0.885 true 0.969,0.51 1.625,0.896 0.656,0.385 12 false Ejector: 1,0.927 2.24,1.615 1.24,0.688 10 false Refrigerant from the cooler condenser assembly 2.229,2.031 4.531,2.729 2.302,0.698 10 false Refrigerant from the evaporator sub-assembly at the downwind side 4.573,1.615 6.167,2.271 1.594,0.656 10 false Suction flow generated by decrease in the pressure 4.083,3.427 5.906,3.719 1.823,0.292 10 false Cooler Condenser Assembly 3.281,6.448 6.365,6.771 3.083,0.323 10 false ECS Type No. 1 Cooler Evaporator Sub-assembly 3.479,5.656 5.344,6.26 1.865,0.604 10 false Capillary Tube (valve to reduce the refrigerant pressure) 4.458,5.104 5.521,5.458 1.063,0.354 10 false Downwind Side 4.521,4.542 5.396,4.854 0.875,0.313 10 false Upwind Side 0.583,3.552 2.208,3.854 1.625,0.302 10 false Cooler Expansion Valve 0.063,0.052 2.208,0.448 2.146,0.396 12 false Ejector Cycle (EJECS 2): 3.885,3.771 6,4.094 2.115,0.323 10 false Compressor with Motor Assembly



ii.

Structure and Operation of Ejector

1.

The ejector is composed of the nozzle, mixing and diffuser sections.

2.

A high temperature and high pressure liquid refrigerant flowing from the cooler condenser assembly is depressurized at the nozzle section and sucks in the low temperature and low pressure gaseous refrigerant from the No. 1 cooler evaporator sub-assembly on the downwind side. The refrigerants are mixed at the mixing section, and the flow speed is decreased at the diffuser section so that the refrigerant is pressurized and flows into the No. 1 cooler evaporator sub-assembly on the upwind side. This achieves the condition where the refrigerant pressure in the No. 1 cooler evaporator sub-assembly on the downwind side is considerably lower than that on the upwind side, creating the lower temperature conditions. Therefore, air cooled by the No. 1 cooler evaporator sub-assembly on the upwind side can be further cooled by the No. 1 cooler evaporator sub-assembly on the downwind side, improving the efficiency of the No. 1 cooler evaporator sub-assembly.

3.

As a result of this, energy efficiency and cooling performance are enhanced. This allows for the reduction in the rotation speed of the electric inverter compressor, resulting in lower power consumption of the air conditioning.

Y102840E10
3.24,2.458 3.063,2.458 3.063,2.458 2.979,3.323 true 5.344,2.406 5.177,2.406 5.177,2.406 5.01,3.177 true 1.542,4.76 1.844,4.76 1.844,4.76 2.438,4.469 true 1.729,4.75 2.521,3.031 true 4.333,5.135 4.021,5.135 4.021,5.135 3.302,4.563 true 4.24,5.125 3.604,3.385 true 0.552,0.729 1.375,1.24 0.823,0.51 10 false From cooler condenser assembly 0.042,1.771 1.99,2.24 1.948,0.469 10 false From the evaporator sub-assembly at the downwind side 1.323,2.677 1.958,3.021 0.635,0.344 10 false Pressure 1.26,3.802 1.969,4.094 0.708,0.292 10 false Flow Rate 0.188,4.625 1.531,5.563 1.344,0.938 10 false Refrigerant flow from cooler condenser assembly 2.469,1.708 2.958,2.021 0.49,0.313 10 false Nozzle 3.021,1.438 3.99,1.823 0.969,0.385 10 false Mixing Section 4.01,1.698 5.021,2.052 1.01,0.354 10 false Diffuser Section 3.302,2.365 4.823,2.802 1.521,0.438 10 true Suction due to decrease in pressure 5.052,0.802 6.844,1.458 1.792,0.656 10 false To the evaporator sub-assembly at the upwind side 5.406,2.292 6.667,2.917 1.26,0.625 10 false Pressure rise due to decrease in speed 4.417,5.042 6.979,5.729 2.563,0.688 10 false Refrigerant flow from the downwind side of the evaporator sub-assembly