Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
NM37H0E _51 Engine / Hybrid System _097147 HYBRID / BATTERY CONTROL _0466532 HYBRID BATTERY SYSTEM DE DETAILS F

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  DETAILS  SERVICE PLUG  


CONSTRUCTION


a.

The service plug grip is connected to the battery module circuit and is used to manually shut off the high-voltage circuit.


b.

The main fuse for the high-voltage circuit is provided inside of the service plug grip.


c.

An interlock switch is provided on the service plug grip. When the grip section is unlocked, the interlock switch is turned off and the EV control ECU assembly shuts off the SMRs. However, to ensure safety, make sure to turn the ignition switch off before removing the service plug grip.

NOTICE:

For further details on how to handle the service plug grip and for other safety cautions, refer to the Repair Manual.


W147889C01
5.823,1.031 6.125,0.469 6.125,0.469 6.323,0.469 true 5.313,2.927 5.5,2.708 5.5,2.708 5.646,2.708 true 6.354,3.302 6.438,3.01 6.438,3.01 6.563,3.01 true 6.448,4.667 6.448,4.292 true 2.49,4.563 2.49,4.188 true 6.208,1.635 6.583,1.219 6.583,1.219 6.781,1.219 true 4.531,4.615 4.844,4.771 0.313,0.156 10 false *2 0.917,4.083 1.229,4.24 0.313,0.156 10 false *3 5.688,2.635 6,2.792 0.313,0.156 10 false *4 6.833,1.135 7.073,1.313 0.24,0.177 10 false *a 6.615,2.938 6.927,3.094 0.313,0.156 10 false *3 6.365,4.698 6.677,4.854 0.313,0.156 10 false *1 2.396,4.594 2.708,4.75 0.313,0.156 10 false *1 6.385,0.396 6.698,0.552 0.313,0.156 10 false *1
*1 Service Plug Grip *2 Main Fuse
*3 Interlock Switch *4 EV Supply Battery Assembly
*a Insulated Glove - -