CONSTRUCTION
To control the pressure of air entering the FC stack assembly, an air shunt valve (FC air pressure regulator assembly) has been adopted at the FC stack assembly air outlet.
To control the pressure of air exhausted from the FC stack, an air pressure regulating valve (FC air pressure regulator assembly) has been adopted at the FC stack assembly air outlet.
The air shunt valve (FC air pressure regulator assembly) controls the DC motor based on requests from the FC control ECU when the system is stopped, and shunts the cathode side.
The air pressure regulating valve (FC air pressure regulator assembly) controls the DC motor based on requests from the FC control ECU, and adjusts pressure when the system is in operation.
| *1 | FC Stack Assembly | *2 | Air Shunt Valve (FC Air Pressure Regulator Assembly) |
|
From Intercooler | - | - |
| *1 | FC Stack Assembly | *2 | Air Pressure Regulating Valve (FC Air Pressure Regulator Assembly) |
|
To Exhaust Pipe | - | - |
The air shunt valve (FC air pressure regulator assembly) and air pressure regulating valve (FC air pressure regulator assembly) are components of the FC stack assembly.