84975
1.INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH) (for LHD)
| *1 | Up Switch |
| *2 | Down Switch |
| *a | Component without harness connected
(Light Control Rheostat (Trip Switch)) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=5,1 |
||
| D7-5 (RV) - D7-1 (E) | Up switch pressed | Below 1 Ω |
| D7-5 (RV) - D7-1 (E) | Up switch not pressed | 10 kΩ or higher |
| D7-5 (RV) - D7-1 (E) | Down switch pressed | 1.71 to 1.89 kΩ |
| D7-5 (RV) - D7-1 (E) | Down switch not pressed | 10 kΩ or higher |
If the result is not as specified, replace the light control rheostat (trip switch).
| *a | Component without harness connected
(Headup Display Switch (Trip Switch)) |
Check illumination.
Apply auxiliary battery voltage to the connector and check the light illumination condition.
| Tester Connection | Specified Condition |
|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=10,6 |
|
| Auxiliary battery positive (+) - D7-10 (ILL+)
Auxiliary battery negative (-) - D7-6 (ILL-) |
Illuminates |
If the result is not as specified, replace the light control rheostat (trip switch).
84975
2.INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH) (for RHD)
| *1 | Up Switch |
| *2 | Down Switch |
| *a | Component without harness connected
(Light Control Rheostat (Trip Switch)) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=5,1 |
||
| D7-5 (RV) - D7-1 (E) | Up switch pressed | Below 1 Ω |
| Up switch not pressed | 10 kΩ or higher | |
| Down switch pressed | 1.71 to 1.89 kΩ | |
| Down switch not pressed | 10 kΩ or higher | |
If the result is not as specified, replace the light control rheostat (trip switch).
| *a | Component without harness connected
(Headup Display Switch (Trip Switch)) |
Check illumination.
Apply auxiliary battery voltage to the connector and check the light illumination condition.
| Tester Connection | Specified Condition |
|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=10,6 |
|
| Auxiliary battery positive (+) - D7-10 (ILL+)
Auxiliary battery negative (-) - D7-6 (ILL-) |
Illuminates |
If the result is not as specified, replace the light control rheostat (trip switch).