84975
1.INSPECT TRIP SWITCH (for LHD)
| *1 | ODO TRIP Switch |
| *a | Component without harness connected
(Trip Switch) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=9,1 |
||
| D7-9 (A/B) - D7-1 (E) | ODO/TRIP switch pressed | Below 1 Ω |
| D7-9 (A/B) - D7-1 (E) | ODO/TRIP switch not pressed | 10 kΩ or higher |
If the result is not as specified, replace the trip switch.
| *a | Component without harness connected
(Trip Switch) |
Check illumination.
Apply auxiliary battery voltage to the connector and check the light illumination condition.
| Tester Connection | Specified Condition |
|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=10,6 |
|
| Auxiliary battery positive (+) → D7-10 (ILL+)
Auxiliary battery negative (-) → D7-6 (ILL-) |
Illuminates |
If the result is not as specified, replace the trip switch.
84975
2.INSPECT TRIP SWITCH (for RHD)
| *1 | ODO TRIP Switch |
| *a | Component without harness connected
(Trip Switch) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=9,1 |
||
| D7-9 (A/B) - D7-1 (E) | ODO/TRIP switch pressed | Below 1 Ω |
| D7-9 (A/B) - D7-1 (E) | ODO/TRIP switch not pressed | 10 kΩ or higher |
If the result is not as specified, replace the trip switch.
| *a | Component without harness connected
(Trip Switch) |
Check illumination.
Apply auxiliary battery voltage to the connector and check the light illumination condition.
| Tester Connection | Specified Condition |
|---|---|
|
Click Location & Routing(D7)Location & Routingewd_type=routing;type=c;code=D7 Click Connector(D7)Instrument Panel>Instrument Panel Wire>Trip Switchewd_type=component;type=c;code=D7;pinno=10,6 |
|
| Auxiliary battery positive (+) → D7-10 (ILL+)
Auxiliary battery negative (-) → D7-6 (ILL-) |
Illuminates |