17C10
1.INSPECT FC AIR PRESSURE REGULATOR ASSEMBLY
| *a | Component without harness connected
(FC Air Pressure Regulator Assembly) |
| *b | Air Sealing Valve |
| *c | Air Pressure Regulating Valve |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B14)Location & Routingewd_type=routing;type=c;code=B14 Click Connector(B14)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Shut Valve)ewd_type=component;type=c;code=B14;pinno=5,6 |
||
| B14-5(M-) - B14-6(M+) | 25 °C (77 °F) | 2.11 to 2.33 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B16)Location & Routingewd_type=routing;type=c;code=B16 Click Connector(B16)Engine Compartment>No. 2 Stack Wire>FC Air Pressure Regulator Assembly (Air Pressure Regulation Valve)ewd_type=component;type=c;code=B16;pinno=5,6 |
||
| B16-5(M-) - B16-6(M+) | 25 °C (77 °F) | 2.11 to 2.33 Ω |
If the result is not as specified, replace the FC air pressure regulator assembly.