Home › Audio / Visual / Telematics › TELEMATICS › TELEMATICS SYSTEM (for eCall)
RM37H0E _56 Audio / Visual / Telematics _095262 TELEMATICS _0447865 TELEMATICS SYSTEM(for eCall) U

TELEMATICS  TELEMATICS SYSTEM(for eCall)  TERMINALS OF ECU  


TELEMATICS TRANSCEIVER


E442558E07
0.406,0.25 0.823,0.5 0.417,0.25 0.896,0.25 1.313,0.5 0.417,0.25 1.385,0.25 1.802,0.5 0.417,0.25 3.083,0.25 3.5,0.5 0.417,0.25 5.167,0.25 5.583,0.5 0.417,0.25 0.448,0.292 0.844,0.521 0.396,0.229 10 false ANT3 0.938,0.292 1.344,0.479 0.406,0.188 10 false ANT2 1.438,0.292 1.833,0.469 0.396,0.177 10 false ANT1 3.188,0.302 3.583,0.542 0.396,0.24 10 false D72 5.26,0.292 5.688,0.49 0.427,0.198 10 false D68

Terminal No. (Symbol) Terminal Description Condition Specified Condition
D68-1 (+B) - D68-20 (E) Power source (+B) Ignition switch off 11 to 14 V
D68-3 (SIG-) - D68-20 (E) Ground Always Below 1 V
D68-4 (IND1) - D68-20 (E) Manual (SOS) switch red indicator illumination signal For 10 seconds after turning the ignition switch to ON 1 to 8.5 V
Ignition switch off Below 1 V
D68-5 (MCVD) - D68-20 (E) Telephone microphone assembly power supply Ignition switch ON 4 to 6 V
Ignition switch off Below 1 V
D68-6 (MCI+) - D68-20 (E) Microphone voice signal Voice being input to telephone microphone assembly A waveform synchronized with microphone voice signal is input
D68-7 (MCI-) - D68-20 (E) Microphone voice signal Always Below 1 V
D68-13 (GSW) - D68-20 (E) Collision detection signal Ignition switch ON Pulse generation (Refer to waveform 1)
D68-14 (MUTE) - D68-20 (E) MUTE Signal Emergency call mode Below 1 V
D68-16 (MCO+) - D68-20 (E) Microphone voice signal Voice being input to telephone microphone assembly A waveform synchronized with microphone voice signal is input
D68-19 (IG2) - D68-20 (E) Power source (IG) Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
D68-20 (E) - Body ground Ground Always Below 1 Ω
D68-21 (SIG1) - D68-3 (SIG-) Manual (SOS) switch button condition signal Manual (SOS) switch not pressed 1.3 to 1.9 V
Manual (SOS) switch pressed 0.5 to 0.8 V
D68-22 (IND2) - D68-20 (E) Manual (SOS) switch green indicator illumination signal For 2 seconds after the ignition switch is turned to ON and the manual (SOS) switch indicator (red) has illuminated for 10 seconds. 1 to 8.5 V
Ignition switch off Below 1 V
D68-23 (SGND) - D68-20 (E) Shield ground Always Below 1 Ω
D68-25 (CANP) CAN communication signal - -
D68-26 (CANN) CAN communication signal - -
D68-32 (MCO-) - D68-20 (E) Microphone voice signal Always Below 1 V
D72-3 (SPO+) - D68-20 (E) Sound signal Audio system playing, or emergency call mode A waveform synchronized with sound signals is output
D72-4 (SPO-) - D68-20 (E) Sound signal Audio system playing, or emergency call mode A waveform synchronized with sound signals is output

a.
E165239E23
0.156,2.313 0.552,2.542 0.396,0.229 10 false GND

Oscilloscope waveform:

i.

Waveform 1

Item Condition
Tester connection D68-13 (GSW) - D68-20 (E)
Tool setting 5.0 V/DIV, 20 ms./DIV
Vehicle condition Ignition switch ON