Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › PEDESTRIAN PROTECTION SYSTEM
RM37H0E _58 Vehicle Interior _095287 SUPPLEMENTAL RESTRAINT SYSTEMS _0454682 PEDESTRIAN PROTECTION SYSTEM D

SUPPLEMENTAL RESTRAINT SYSTEMS  PEDESTRIAN PROTECTION SYSTEM  SYSTEM DESCRIPTION  


FUNCTION OF SRS CONNECTORS


a.

Location of activation prevention mechanism

E454793E01
4.833,0.24 6.563,0.438 1.729,0.198 10 false Airbag ECU Assembly 0.135,1.906 2.823,2.083 2.688,0.177 10 false Pop Up Hood Lifter Assembly RH 0.135,2.927 2.719,3.281 2.583,0.354 10 false Pedestrian Detection Chamber Assembly (Pedestrian Protection Sensor) 0.135,4.115 2.823,4.292 2.688,0.177 10 false Pop Up Hood Lifter Assembly LH


b.

Function of activation prevention mechanism

C241774E11
2.771,1.177 3.385,0.917 3.385,0.917 3,1.25 false 3.031,1.542 3.26,1.719 false 2,0.896 1.521,0.75 false 1.958,1.25 1.469,1.25 false 2.177,1.469 1.677,1.688 false 5.302,1.323 5.302,1.906 false 2.188,0.385 3,0.563 0.813,0.177 10 false When open 0.594,0.615 1.792,0.802 1.198,0.188 10 false Male Housing 0.583,1.156 1.781,1.333 1.198,0.177 10 false Male Terminal 0.448,1.615 1.917,1.844 1.469,0.229 10 false Short Spring Plate 3.302,1.667 4.51,1.948 1.208,0.281 10 false Female Housing 3.438,0.844 4.656,1.021 1.219,0.177 10 false Female Terminal 5.49,0.344 6.25,0.531 0.76,0.188 10 false When short 4.552,1.948 6.573,2.292 2.021,0.344 10 false Short spring plate contacting the male terminal

i.

The activation prevention mechanism is designed to create a short circuit automatically between the positive (+) and negative (-) terminals of a pop up hood lifter power source connector when disconnected.


ii.

The short spring plate contained in the connector creates a closed circuit on the pop up hood lifter side (no potential difference can occur between both terminals), preventing accidental pop up hood lifter deployment when servicing.



c.

Releasing of activation prevention mechanism

i.

To release the activation prevention mechanism, insert a piece of paper with the same thickness as the male terminal (approximately 0.5 mm [0.0197 in.]) between the terminals and short spring to break the connection.


ii.

Refer to the following illustrations concerning connectors utilizing the activation prevention mechanism and its release method.

CAUTION:

Never release the activation prevention mechanism on the squib connector even when inspecting with the squib disconnected.


NOTICE:
·

Do not release the activation prevention mechanism unless specified by the troubleshooting procedure.

·

To prevent the terminals and short spring from being damaged, always use a piece of paper with the same thickness as the male terminal.



HINT:

To prevent improper operation due to static electricity, etc., the connector of the pedestrian protection system circuit has a short mechanism, and the pop up hood lifter terminal is shorted while the connector is disconnected.


C411184C05
2.51,3.979 1.719,4.896 1.719,4.896 2.5,3.792 true 1.51,4.906 1.698,4.906 1.698,4.906 2.542,4.198 true 5.271,3.979 4.479,4.896 4.479,4.896 5.26,3.792 true 4.281,4.927 4.469,4.927 4.469,4.927 5.313,4.219 true 3.344,3.729 3.74,3.271 3.74,3.271 3.906,3.271 false 3.344,3.917 3.75,3.281 3.75,3.281 3.365,4.146 false 5.813,3.917 6.219,3.281 6.219,3.281 5.833,4.146 false 5.823,3.729 6.219,3.271 6.219,3.271 6.385,3.271 false 0.135,0.083 4.479,0.573 4.344,0.49 10 false Wire Harness Connector (to Airbag ECU Assembly): 1.594,2.719 3.302,3.073 1.708,0.354 10 false Before Release 4.01,3.198 4.615,3.469 0.604,0.271 10 false Paper 0.667,4.823 2.635,5.323 1.969,0.5 10 false Short Spring 6.438,3.188 7.042,3.458 0.604,0.271 10 false Paper 4.292,2.667 6,3.021 1.708,0.354 10 false After Release 3.406,4.823 5.375,5.323 1.969,0.5 10 false Short Spring
V100144

Short Spring - -