88719A
1.INSPECT AIR CONDITIONER PRESSURE SENSOR
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
| *b | Front view of wire harness connector
(to Air Conditioning Amplifier Assembly) |
Check the wire harness.
Disconnect the A34 air conditioner pressure sensor connector.
Disconnect the D80 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A34,D80)Location & Routingewd_type=routing;type=c,c;code=A34,D80 Click Connector(D80)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D80;pinno=15,6,11 |
||
| A34-1 (-) - D80-15 (SG-4) | Always | Below 1 Ω |
| A34-2 (PR) - D80-6 (PRE) | Always | Below 1 Ω |
| A34-3 (+) - D80-11 (S5 -3) | Always | Below 1 Ω |
| A34-1 (-) - Body ground | Always | 10 kΩ or higher |
| D80-15 (SG-4) - Body ground | Always | 10 kΩ or higher |
| A34-2 (PR) - Body ground | Always | 10 kΩ or higher |
| D80-6 (PRE) - Body ground | Always | 10 kΩ or higher |
| A34-3 (+) - Body ground | Always | 10 kΩ or higher |
| D80-11 (S5 -3) - Body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair the wire harness.
Check the voltage.
Reconnect the D80 air conditioning amplifier assembly connector.
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A34)Location & Routingewd_type=routing;type=c;code=A34 |
||
| A34-3 (+) - Body ground | Power switch on (IG) | 4.75 to 5.25 V |
If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Install a manifold gauge set.
Connect the A34 air conditioner pressure sensor connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
*:Value when sensor power source voltage is 5 V |
||
|
Click Location & Routing(D80)Location & Routingewd_type=routing;type=c;code=D80 Click Connector(D80)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D80;pinno=6,15 |
||
| D80-6 (PRE) - D80-15 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.62 to 4.73 V* |
| D80-6 (PRE) - D80-15 (SG-4) | Refrigerant pressure: Abnormal pressure (below 176 kPa (1.8 kgf/cm2, 26 psi), or 3025 kPa (30.8 kgf/cm2, 439 psi) or higher) | Below 0.62 V, or 4.74 V or higher* |
If the result is not as specified, there may be a malfunction in the air conditioner pressure sensor.