HEATING / AIR CONDITIONING  AIR CONDITIONING PRESSURE SENSOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 88719A 1.INSPECT AIR CONDITIONER PRESSURE SENSOR

E399448C10
1.521,0.135 1.938,0.333 0.417,0.198 1.583,1.25 2,1.417 0.417,0.167 1.531,1.635 1.948,1.844 0.417,0.208 1.083,1.417 1.5,1 true 2.406,0.583 1.729,0.906 true 1.948,0.99 2.281,1.406 true 0.635,2.375 1.448,2.542 true 2.813,2.354 2.135,2.542 true 0.667,3.177 1.25,2.823 true 0.521,0.25 0.833,0.406 0.313,0.156 10 false *a 0.5,1.51 0.813,1.667 0.313,0.156 10 false *b 1.604,0.167 2.063,0.365 0.458,0.198 10 false A34 1.625,1.656 1.969,1.823 0.344,0.167 10 false D80 0.917,1.427 1.073,1.625 0.156,0.198 10 false - 2.323,1.396 2.479,1.594 0.156,0.198 10 false + 2.5,0.5 2.813,0.698 0.313,0.198 10 false PR 0.292,3.115 0.74,3.313 0.448,0.198 10 false SG-4 0.354,2.271 0.813,2.469 0.458,0.198 10 false PRE 2.875,2.26 3.323,2.427 0.448,0.167 10 false S5-3
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)
*b Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)


a.

Check the wire harness.

i.

Disconnect the A34 air conditioner pressure sensor connector.


ii.

Disconnect the D80 air conditioning amplifier assembly connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(A34,D80)Location & Routing

Click Connector(A34)Engine Compartment>Front Compartment Main Wire / No. 3 Front Compartment Wire / No. 4 Front Compartment Wire>Air Conditioning Pressure Sensor

Click Connector(D80)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assembly

A34-1 (-) - D80-15 (SG-4) Always Below 1 Ω
A34-2 (PR) - D80-6 (PRE) Always Below 1 Ω
A34-3 (+) - D80-11 (S5 -3) Always Below 1 Ω
A34-1 (-) - Body ground Always 10 kΩ or higher
D80-15 (SG-4) - Body ground Always 10 kΩ or higher
A34-2 (PR) - Body ground Always 10 kΩ or higher
D80-6 (PRE) - Body ground Always 10 kΩ or higher
A34-3 (+) - Body ground Always 10 kΩ or higher
D80-11 (S5 -3) - Body ground Always 10 kΩ or higher


If the resistance is not as specified, repair the wire harness.



b.

Check the voltage.

i.

Reconnect the D80 air conditioning amplifier assembly connector.


ii.
E399449C09
1.521,0.198 1.917,0.427 0.396,0.229 2.396,1.896 1.99,1.458 true 0.521,0.26 0.833,0.417 0.313,0.156 10 false *a 1.594,0.25 1.969,0.469 0.375,0.219 10 false A34 2.438,1.885 2.594,2.083 0.156,0.198 10 false +
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(A34)Location & Routing

Click Connector(A34)Engine Compartment>Front Compartment Main Wire / No. 3 Front Compartment Wire / No. 4 Front Compartment Wire>Air Conditioning Pressure Sensor

A34-3 (+) - Body ground Power switch on (IG) 4.75 to 5.25 V


If the voltage is not as specified, repair the wire harness or replace air conditioning amplifier assembly.



c.

Check the air conditioner pressure sensor.

i.

Install a manifold gauge set.


ii.

Connect the A34 air conditioner pressure sensor connector.


iii.

Turn the power switch on (IG).


iv.

Measure the voltage according to the value(s) in the table below.

E399450C10
2.156,0.302 2.51,0.5 0.354,0.198 2.542,1.417 1.167,0.729 true 2.677,1.635 1.219,2.01 true 0.521,0.26 0.833,0.417 0.313,0.156 10 false *a 2.219,0.323 2.677,0.521 0.458,0.198 10 false D80 0.854,0.656 1.313,0.854 0.458,0.198 10 false PRE 0.854,1.99 1.313,2.198 0.458,0.208 10 false SG-4
*a Component with harness connected
(Air Conditioning Amplifier)
- -


Standard Voltage:
Tester Connection Condition Specified Condition

*:Value when sensor power source voltage is 5 V

Click Location & Routing(D80)Location & Routing

Click Connector(D80)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assembly

D80-6 (PRE) - D80-15 (SG-4) Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) 0.62 to 4.73 V*
D80-6 (PRE) - D80-15 (SG-4) Refrigerant pressure: Abnormal pressure (below 176 kPa (1.8 kgf/cm2, 26 psi), or 3025 kPa (30.8 kgf/cm2, 439 psi) or higher) Below 0.62 V, or 4.74 V or higher*


If the result is not as specified, there may be a malfunction in the air conditioner pressure sensor.