RM37H0E
_V1
General
_095078
SPECIFICATIONS
_0455014
Q710 HYBRID TRANSMISSION / TRANSAXLE
F
SPECIFICATIONS Q710 HYBRID TRANSMISSION / TRANSAXLE SERVICE DATA
HYBRID TRANSAXLE FLUID
|
|
| Hybrid transaxle fluid standard capacity (for Reference)
|
Classification
|
| 5.6 liters (5.9 US qts, 4.9 Imp. qts)
|
Toyota Genuine ATF WS*
|
OIL PUMP (for Mechanical Type)
| Condition
|
Specified Condition
|
| Motor Revoluton
|
Transaxle Oil Temperature
|
| 3000 to 3200 rpm
|
20 to 50°C (68 to 122°F)
|
4.0 kPa (0.04 kgf/cm2, 0.6 psi) or more
|
HYBRID TRANSAXLE OIL SEAL
| Rear drive shaft oil seal RH
|
Standard Depth
|
-0.5 to 0.5 mm (-0.0197 to 0.0197 in.)
|
| Rear drive shaft oil seal LH
|
Standard Depth
|
-0.5 to 0.5 mm (-0.0197 to 0.0197 in.)
|
SHIFT CONTROL ACTUATOR
| Shift control actuator seal
|
Installation Depth
|
6.5 to 7.3 mm (0.256 to 0.287 in.)
|
| Measurement Condition
|
Specified Condition
|
Battery positive (+) → D17-7 (IND+)
Battery negative (-) → D17-4 (IND-)
|
Illuminates
|
Battery positive (+) → D17-1 (ILL+)
Battery negative (-) → D17-10 (ILL-)
|
Illuminates
|
PATTERN SELECT SWITCH
| No. 1 pattern select switch assembly (DRIVE MODE):
|
| Tester Connection
|
Condition
|
Specified Condition
|
| D5-1 (DMS+) - D5-3 (E)
|
When the DRIVE MODE switch is operated and held on the top side
|
Below 10 Ω
|
D5-1 (DMS+) - D5-3 (E)
D5-4 (DMS-) - D5-3 (E)
|
When the DRIVE MODE switch is not operated
|
10 kΩ or higher
|
| D5-4 (DMS-) - D5-3 (E)
|
When the DRIVE MODE switch is operated and held on the bottom side
|
Below 10 Ω
|
| No. 1 pattern select switch assembly (DRIVE MODE):
|
| Measurement Condition
|
Specified Condition
|
Battery positive (+) → D5-5 (ILL+)
Battery negative (-) → D5-2 (ILL-)
|
Illuminates
|
| Pattern select switch assembly (SNOW):
|
| Tester Connection
|
Condition
|
Specified Condition
|
| D74-5 (SNSW) - D74-2 (E)
|
SNOW mode switch pushed and held
|
Below 10 Ω
|
| D74-5 (SNSW) - D74-2 (E)
|
SNOW mode switch not pushed
|
10 kΩ or higher
|
| Pattern select switch assembly (SNOW):
|
| Measurement Condition
|
Specified Condition
|
Battery positive (+) → D74-6 (ILL+)
Battery negative (-) → D74-1 (ILL-)
|
Illuminates
|
RELAY
| OIL PMP MTR RELAY:
|
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage is not applied to terminal 1 and 2
|
10 MΩ or higher
|
| 3 - 5
|
Battery voltage is applied to terminal 1 and 2
|
Below 1 Ω
|
| P CON MTR RELAY:
|
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage is not applied to terminal 1 and 2
|
10 MΩ or higher
|
| 3 - 5
|
Battery voltage is applied to terminal 1 and 2
|
Below 1 Ω
|
| IG2 P RELAY:
|
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage is not applied to terminal 1 and 2
|
10 MΩ or higher
|
| 3 - 5
|
Battery voltage is applied to terminal 1 and 2
|
Below 1 Ω
|
| LUG-IG1 No. 1 RELAY:
|
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 5
|
Battery voltage is not applied to terminal 1 and 2
|
10 MΩ or higher
|
| 3 - 5
|
Battery voltage is applied to terminal 1 and 2
|
Below 1 Ω
|