DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor (room temperatures sensor) | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | Cooler thermistor system malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Thermistor assembly system malfunction
·
When open circuit: -23.30°C (-9.94°F) ·
When short circuit: 65.95°C (150.71°F) |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F) |
Adjust ambient temperature displayed | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | No. 1 cooler thermistor system malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | No. 1 cooler thermistor system malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | ·
FC control system malfunction ·
CAN communication system malfunction |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower with fan motor sub-assembly system malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG
Max.: 3.2943 MPaG |
Actual refrigerant pressure displayed | - |
| Air Mix Servo Targ Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse |
Min.: 128
Max.: 383 |
for LHD (for Dual):
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) for LHD (for 3 Zone):
·
MAX COLD: 254 (pulse) ·
MAX HOT: 358 (pulse) for RHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) |
for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction |
| Air Mix Servo Actual Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) actual pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) actual pulse |
Min.: 128
Max.: 383 |
for LHD (for Dual):
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) for LHD (for 3 Zone):
·
MAX COLD: 254 (pulse) ·
MAX HOT: 358 (pulse) for RHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) |
for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction |
| Air Mix Servo Targ Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) target pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) for RHD (for Dual):
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) for RHD (for 3 Zone):
·
MAX COLD: 254 (pulse) ·
MAX HOT: 358 (pulse) |
for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction |
| Air Mix Servo Actual Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) for RHD (for Dual):
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) for RHD (for 3 Zone):
·
MAX COLD: 254 (pulse) ·
MAX HOT: 358 (pulse) |
for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
for LHD:
·
Recirculation: 258 (pulse) ·
Fresh: 290 (pulse) ·
Two-layer: 274 (pulse) for RHD:
·
Recirculation: 222 (pulse) ·
Fresh: 254 (pulse) ·
Two-layer: 238 (pulse) |
No. 1 blower damper servo sub-assembly system malfunction |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
Recirculation: 258 (pulse) ·
Fresh: 290 (pulse) ·
Two-layer: 274 (pulse) for RHD:
·
Recirculation: 222 (pulse) ·
Fresh: 254 (pulse) ·
Two-layer: 238 (pulse) |
No. 1 blower damper servo sub-assembly system malfunction |
| Electric Heater Count | Maximum electric heater operation level | Min.: 0
Max.: 2 |
Maximum possible operation level of electric heater displayed | - |
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0
Max.: 2 |
Actual operation level of electric heater displayed | - |
| Compressor Speed | Compressor speed | Min.: 0 rpm
Max.: 65535 rpm |
Actual compressor rotation speed displayed | - |
| Compressor Target Speed | Compressor target speed | Min.: 0 rpm
Max.: 65535 rpm |
Compressor target rotation speed displayed | - |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | - |
| Evaporator Control | Compressor mode | Auto or Manual | Customized value displayed | - |
| Add Foot Air in FACE Mode | Add foot air in face mode | ON or OFF | Customized value displayed | - |
| Noise and Vibration Reduction | Noise and vibration reduction | ON or OFF | Customized value displayed | - |
| ECO MODE Cancel | ECO drive mode cancel | OFF or ON | Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow, Normal, Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr | Customized value displayed | - |
| COOL A/M Servo Targ Pls(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) target pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 254 (pulse) ·
MAX HOT: 326 (pulse) for RHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 186 (pulse) |
for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction |
| COOL A/M Servo Actual Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) actual pulse for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 254 (pulse) ·
MAX HOT: 326 (pulse) for RHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 186 (pulse) |
for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction |
| COOL A/M Servo Targ Pls(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) target pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 186 (pulse) for RHD:
·
MAX COLD: 254 (pulse) ·
MAX HOT: 326 (pulse) |
for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction |
| COOL A/M Servo Actual Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) actual pulse for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
MAX COLD: 258 (pulse) ·
MAX HOT: 186 (pulse) for RHD:
·
MAX COLD: 254 (pulse) ·
MAX HOT: 326 (pulse) |
for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction |
| A/O Damper FACE Pos(D) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) target pulse for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE1, 2: 258 (pulse) ·
FACE A/M: 275 (pulse) ·
B/L: 289 (pulse) ·
F/D: 335 (pulse) ·
FOOT-0: 345 (pulse) ·
Stay smell: 346 (pulse) ·
FOOT-D: 347 (pulse) ·
D/F: 348 (pulse) ·
FOOT-R, F: 349 (pulse) ·
DEF: 364 (pulse) for RHD:
·
FACE1, 2: 254 (pulse) ·
FACE A/M: 237 (pulse) ·
B/L: 198 (pulse) ·
F/D: 177 (pulse) ·
Stay smell, FOOT-F: 166 (pulse) ·
FOOT-R: 165 (pulse) ·
DEF: 148 (pulse) |
for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction |
| A/O Damper FACE Actual Pos(D) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) actual pulse for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE1, 2: 258 (pulse) ·
FACE A/M: 275 (pulse) ·
B/L: 289 (pulse) ·
F/D: 335 (pulse) ·
FOOT-0: 345 (pulse) ·
Stay smell: 346 (pulse) ·
FOOT-D: 347 (pulse) ·
D/F: 348 (pulse) ·
FOOT-R, F: 349 (pulse) ·
DEF: 364 (pulse) for RHD:
·
FACE1, 2: 254 (pulse) ·
FACE A/M: 237 (pulse) ·
B/L: 198 (pulse) ·
F/D: 177 (pulse) ·
Stay smell, FOOT-F: 166 (pulse) ·
FOOT-R: 165 (pulse) ·
DEF: 148 (pulse) |
for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction |
| A/O Damper FOOT/DEF Pos(D) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) target pulse for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE2: 258 (pulse) ·
FACE1: 267 (pulse) ·
FACE A/M: 283 (pulse) ·
B/L, FOOT-0, R, D: 292 (pulse) ·
Stay smell: 308 (pulse) ·
FOOT-F: 317 (pulse) ·
F/D: 328 (pulse) ·
D/F: 342 (pulse) ·
DEF: 365 (pulse) for RHD:
·
FACE2: 254 (pulse) ·
FACE1: 245 (pulse) ·
FACE A/M: 229 (pulse) ·
B/L, FOOT-0, FOOT-R, FOOT-D: 220 (pulse) ·
Stay smell: 204 (pulse) ·
FOOT-F: 195 (pulse) ·
F/D: 184 (pulse) ·
DEF: 147 (pulse) |
for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction |
| A/O Damper FOOT/DEF Act Pos(D) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) actual pulse for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE2: 258 (pulse) ·
FACE1: 267 (pulse) ·
FACE A/M: 283 (pulse) ·
B/L, FOOT-0, R, D: 292 (pulse) ·
Stay smell: 308 (pulse) ·
FOOT-F: 317 (pulse) ·
F/D: 328 (pulse) ·
D/F: 342 (pulse) ·
DEF: 365 (pulse) for RHD:
·
FACE2: 254 (pulse) ·
FACE1: 245 (pulse) ·
FACE A/M: 229 (pulse) ·
B/L, FOOT-0, FOOT-R, FOOT-D: 220 (pulse) ·
Stay smell: 204 (pulse) ·
FOOT-F: 195 (pulse) ·
F/D: 184 (pulse) ·
DEF: 147 (pulse) |
for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction |
| A/O Damper FACE Pos(P) | No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
FACE1, 2: 254 (pulse) ·
FACE A/M: 237 (pulse) ·
B/L: 223 (pulse) ·
F/D: 177 (pulse) ·
FOOT-0: 167 (pulse) ·
Stay smell, FOOT-F: 166 (pulse) ·
FOOT-D: 165 (pulse) ·
FOOT-F, R: 163 (pulse) ·
DEF: 148 (pulse) for RHD:
·
FACE1, FACE2: 258 (pulse) ·
FACE A/M: 275 (pulse) ·
B/L: 314 (pulse) ·
F/D: 335 (pulse) ·
Stay smell, FOOT-F: 346 (pulse) ·
FOOT-D: 346 (pulse) ·
D/F, FOOT-0, FOOTR: 347 (pulse) ·
DEF: 364 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) system malfunction
(for 3 Zone) |
| A/O Damper FACE Actual Pos(P) | No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
FACE1, 2: 254 (pulse) ·
FACE A/M: 237 (pulse) ·
B/L: 223 (pulse) ·
F/D: 177 (pulse) ·
FOOT-0: 167 (pulse) ·
Stay smell, FOOT-F: 166 (pulse) ·
FOOT-D: 165 (pulse) ·
FOOT-F, R: 163 (pulse) ·
DEF: 148 (pulse) for RHD:
·
FACE1, FACE2: 258 (pulse) ·
FACE A/M: 275 (pulse) ·
B/L: 314 (pulse) ·
F/D: 335 (pulse) ·
Stay smell, FOOT-F: 346 (pulse) ·
FOOT-D: 346 (pulse) ·
D/F, FOOT-0, FOOTR: 347 (pulse) ·
DEF: 364 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) system malfunction
(for 3 Zone) |
| A/O Damper FOOT/DEF Pos(P) | No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) target pulse | Min.: 128
Max.: 383 |
for LHD:
·
FACE1, 2: 254 (pulse) ·
FACE A/M: 237 (pulse) ·
B/L: 223 (pulse) ·
F/D: 177 (pulse) ·
FOOT-0: 167 (pulse) ·
Stay smell, FOOT-F: 166 (pulse) ·
FOOT-D: 165 (pulse) ·
FOOT-F, R: 163 (pulse) ·
DEF: 148 (pulse) for RHD:
·
FACE2: 258 (pulse) ·
FACE1: 267 (pulse) ·
FACE A/M: 283 (pulse) ·
B/L, FOOT-0, FOOT-R, FOOT-D: 292 (pulse) ·
Stay smell: 308 (pulse) ·
FOOT-F: 317 (pulse) ·
F/D: 328 (pulse) ·
DEF: 365 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) system malfunction
(for 3 Zone) |
| A/O Damper FOOT/DEF Act Pos(P) | No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) actual pulse | Min.: 128
Max.: 383 |
for LHD:
·
FACE1, 2: 254 (pulse) ·
FACE A/M: 237 (pulse) ·
B/L: 223 (pulse) ·
F/D: 177 (pulse) ·
FOOT-0: 167 (pulse) ·
Stay smell, FOOT-F: 166 (pulse) ·
FOOT-D: 165 (pulse) ·
FOOT-F, R: 163 (pulse) ·
DEF: 148 (pulse) for RHD:
·
FACE2: 258 (pulse) ·
FACE1: 267 (pulse) ·
FACE A/M: 283 (pulse) ·
B/L, FOOT-0, FOOT-R, FOOT-D: 292 (pulse) ·
Stay smell: 308 (pulse) ·
FOOT-F: 317 (pulse) ·
F/D: 328 (pulse) ·
DEF: 365 (pulse) |
No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) system malfunction
(for 3 Zone) |
| Air Mix Servo Targ Pls(F&R D) | No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) target pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) system malfunction |
| A/M Servo Actual Pulse(F&R D) | No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) actual pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 258 (pulse) ·
MAX HOT: 154 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) system malfunction |
| Air Outlet Servo Pls (F&R D) | for LHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) target pulse for RHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) target pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE1, A/M: 249 (pulse) ·
FACE2: 252 (pulse) ·
B/L: 266 (pulse) ·
FOOT-ALL: 274 (pulse) ·
F/D: 280 (pulse) ·
D/F: 286 (pulse) ·
DEF: 289 (pulse) for RHD:
·
FACE1, A/M: 263 (pulse) ·
FACE2: 260 (pulse) ·
B/L: 249 (pulse) ·
FOOT-ALL: 238 (pulse) ·
F/D: 232 (pulse) ·
DEF: 289 (pulse) |
for LHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction for RHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction |
| A/O Servo Actual Pulse(F&R D) | for LHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) actual pulse for RHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) actual pulse |
Min.: 128
Max.: 383 |
for LHD:
·
FACE1, A/M: 249 (pulse) ·
FACE2: 252 (pulse) ·
B/L: 266 (pulse) ·
FOOT-ALL: 274 (pulse) ·
F/D: 280 (pulse) ·
D/F: 286 (pulse) ·
DEF: 289 (pulse) for RHD:
·
FACE1, A/M: 263 (pulse) ·
FACE2: 260 (pulse) ·
B/L: 249 (pulse) ·
FOOT-ALL: 238 (pulse) ·
F/D: 232 (pulse) ·
DEF: 289 (pulse) |
for LHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction for RHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction |
| A/O Damper DEF Pos(D Side) | for LHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) target pulse for RHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) target pulse |
Min.: 128
Max.: 383 |
·
DEF, F/D, D/F: 242 (pulse) ·
FOOT-D: 331 (pulse) ·
FOOT-R, FOOT-F: 332 (pulse) ·
FACE, B/L, FOOT-0: 348 (pulse) |
for LHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction for RHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction |
| A/O Damper DEF Actual Pos(D) | for LHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) actual pulse for RHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) actual pulse |
Min.: 128
Max.: 383 |
·
DEF, F/D, D/F: 242 (pulse) ·
FOOT-D: 331 (pulse) ·
FOOT-R, FOOT-F: 332 (pulse) ·
FACE, B/L, FOOT-0: 348 (pulse) |
for LHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction for RHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction |
| Compressor Drive Check | Compressor drive check | OK or NG | NG: Compressor does not drive
OK: Compressor drives |
- |
| Glass Temperature | Glass temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual glass temperature is displayed | Not applicated |
| Glass Surroundings Temperature | Glass surroundings temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual glass surroundings temperature is displayed | Not applicated |
| Glass Humidity | Glass humidity | Min.: 0.00%
Max.: 100.00% |
Actual glass humidity is displayed | Not applicated |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Front passenger side set temperature displayed | - |
| Set Temperature (Rear) | Rear side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Rear side set temperature displayed | - |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | - |
| Heater Valve Position | Three-way valve actual position | Min.: -14.0%
Max.: 113.5% |
Three-way valve actual position | - |
| S-FLOW Control Auto Function | S-FLOW control auto function | ON or OFF | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
| Refrigerant High Pressure History | History of refigerant high pressure in the past | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure in the past displayed |
|
| High Voltage Electric Heater Inlet Coolant Temperature Sensor | High voltage electric heater inlet temperature | -327.68 to 327.67 °C (-557.82 to 621.81 °F) | High voltage electric heater inlet temperature displayed | - |
| High Voltage Electric Heater Outlet Coolant Temperature Sensor | High voltage electric heater outlet temperature | -327.68 to 327.67 °C (-557.82 to 621.81 °F) | High voltage electric heater outlet temperature displayed | - |
| High Voltage Electric Heater Target Electric Power | High voltage electric heater target power | 0 to 12750 W | High voltage electric heater target power displayed | - |
| High Voltage Electric Heater Consumption Electric Power | High voltage electric heater actual power | 0 to 12750 W | High voltage electric heater actual power displayed | - |
| High Voltage Electric Heater Overheat Detection Status | Number of over heat at high voltage electric heater | 0 to 3 | Number of over heat at high voltage electric heater displayed | - |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| PTC Heater No.1 Input Signal | Quick heater assembly input status | OFF or ON | OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates |
- |
| PTC Heater No.2 Input Signal | Quick heater assembly input status | OFF or ON | OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates |
- |
| PTC Heater No.1 Output Signal | Quick heater assembly output status | OFF or ON | OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates |
- |
| PTC Heater No.2 Output Signal | Quick heater assembly output status | OFF or ON | OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates |
- |
| PTC Heater No.1 Output Current | Quick heater assembly current | 0 to 65535 A | 2 A or less | - |
| PTC Heater No.2 Output Current | Quick heater assembly current | 0 to 65535 A | 2 A or less | - |
| Status of PTC Heater No.1 Fuse | Quick heater assembly fuse | Connect or Disconnect | Connect: Fuse not shut off
Disconnect: Fuse shut off |
- |
| Status of PTC Heater No.2 Fuse | Quick heater assembly fuse | Connect or Disconnect | Connect: Fuse not shut off
Disconnect: Fuse shut off |
- |
| PTC Heater No.1 Fuse Shut Off History | Quick heater assembly fuse shut off history | OFF or ON | OFF: Fuse has no shut off history
ON: Fuse has shut off history |
- |
| PTC Heater No.2 Fuse Shut Off History | Quick heater assembly fuse shut off history | OFF or ON | OFF: Fuse has no shut off history
ON: Fuse has shut off history |
- |
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Target FC Current (Filtered Value) | FC stack outlet coolant temperature | -40°C to 215.9 °C (-40°F to 421 °F) | 50 to 85 °C (122 to 185 °F): After warming up | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0
Max.: 7500 |
Perform this test when the ignition switch ON (READY) |
| Water Pump | Water with motor pump assembly | OFF/ON | Perform this test when the following conditions are met:
·
Ignition switch ON (READY) ·
Air conditioning system is operated |
| Heater Active Level | Quick heater assembly | Min.: 0
Max.: 2 |
Perform this test when the following conditions are met:
·
Ignition switch ON (READY) ·
Air conditioning system is operated |
| Air Mix Servo Targ Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation |
Min.: 128
Max.: 383 |
for LHD (for Dual):
Operates between 154 to 258 pulses for LHD (for 3 Zone):
Operates between 254 to 358 pulses for RHD:
Operates between 154 to 258 pulses |
| Air Mix Servo Targ Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 154 to 258 pulses for RHD (for Dual):
Operates between 154 to 258 pulses for RHD (for 3 Zone):
Operates between 254 to 358 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 258 to 290 pulses for RHD:
Operates between 222 to 254 pulses |
| Cool A/M Servo Pulse(D) | for LHD:
No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation for RHD:
No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 254 and 326 pulses for RHD:
Operates between 186 to 258 pulses |
| Cool A/M Servo Pulse(P) | for LHD:
No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation for RHD:
No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 186 and 258 pulses for RHD:
Operates between 254 to 326 pulses |
| Face A/O Servo Pulse(D) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) operation for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 258 and 364 pulses for RHD:
Operates between 148 to 254 pulses |
| Foot A/O Servo Pulse(D) | for LHD:
No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (Driver side MODE FOOT (for 3 Zone)) operation for RHD:
No. 3 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (Driver side MODE FOOT (for 3 Zone)) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 258 and 365 pulses for RHD:
Operates between 147 to 254 pulses |
| Face A/O Servo Pulse(P) | No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) operation | Min.: 128
Max.: 383 |
for LHD:
Operates between 147 and 254 pulses for RHD:
Operates between 258 and 364 pulses |
| Foot A/O Servo Pulse(P) | No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) operation | Min.: 128
Max.: 383 |
for LHD:
Operates between 148 and 254 pulses for RHD:
Operates between 258 and 365 pulses |
| A/M Servo Pulse(F&R D) | No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) operation | Min.: 128
Max.: 383 |
Operates between 154 and 258 pulses |
| A/O Servo Pulse(F&R D) | for LHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) operation for RHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 249 and 289 pulses for RHD:
Operates between 263 and 289 pulses (for 3 Zone) |
| DEF A/O Servo Pulse(D) | for LHD:
No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) operation for RHD:
No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) operation |
Min.: 128
Max.: 383 |
for LHD:
Operates between 249 and 289 pulses for RHD:
Operates between 263 and 289 pulses (for 3 Zone) |
| Heater Valve | 3 way valve operation | Close, Half, Open | - |
| High Voltage Electric Heater | High voltage electric heater operation | 0 to 12750 | Perform this test when the following conditions are met:
·
Blower switch: HI ·
Air conditioning system is operated |