HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler thermistor (room temperatures sensor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Cooler thermistor system malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed Thermistor assembly system malfunction
·

When open circuit: -23.30°C (-9.94°F)

·

When short circuit: 65.95°C (150.71°F)


Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Adjust ambient temperature displayed -
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed No. 1 cooler thermistor system malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed No. 1 cooler thermistor system malfunction
·

When open circuit: -327.68°C (-557.82°F)

·

When short circuit: 327.67°C (621.81°F)


Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed
·

FC control system malfunction

·

CAN communication system malfunction


Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases Blower with fan motor sub-assembly system malfunction
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual refrigerant pressure displayed -
Air Mix Servo Targ Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse


Min.: 128
Max.: 383
for LHD (for Dual):
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for LHD (for 3 Zone):
·

MAX COLD: 254 (pulse)

·

MAX HOT: 358 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction


Air Mix Servo Actual Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) actual pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) actual pulse


Min.: 128
Max.: 383
for LHD (for Dual):
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for LHD (for 3 Zone):
·

MAX COLD: 254 (pulse)

·

MAX HOT: 358 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) system malfunction


Air Mix Servo Targ Pulse(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) target pulse


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) target pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for RHD (for Dual):
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for RHD (for 3 Zone):
·

MAX COLD: 254 (pulse)

·

MAX HOT: 358 (pulse)


for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction


Air Mix Servo Actual Pulse(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual pulse


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for RHD (for Dual):
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


for RHD (for 3 Zone):
·

MAX COLD: 254 (pulse)

·

MAX HOT: 358 (pulse)


for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) system malfunction


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly target pulse Min.: 128
Max.: 383
for LHD:
·

Recirculation: 258 (pulse)

·

Fresh: 290 (pulse)

·

Two-layer: 274 (pulse)


for RHD:
·

Recirculation: 222 (pulse)

·

Fresh: 254 (pulse)

·

Two-layer: 238 (pulse)


No. 1 blower damper servo sub-assembly system malfunction
Air Inlet Damper Actual Pulse No. 1 blower damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for LHD:
·

Recirculation: 258 (pulse)

·

Fresh: 290 (pulse)

·

Two-layer: 274 (pulse)


for RHD:
·

Recirculation: 222 (pulse)

·

Fresh: 254 (pulse)

·

Two-layer: 238 (pulse)


No. 1 blower damper servo sub-assembly system malfunction
Electric Heater Count Maximum electric heater operation level Min.: 0
Max.: 2
Maximum possible operation level of electric heater displayed -
Electric Heater Active Level Actual electric heater operation level Min.: 0
Max.: 2
Actual operation level of electric heater displayed -
Compressor Speed Compressor speed Min.: 0 rpm
Max.: 65535 rpm
Actual compressor rotation speed displayed -
Compressor Target Speed Compressor target speed Min.: 0 rpm
Max.: 65535 rpm
Compressor target rotation speed displayed -
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Evaporator Control Compressor mode Auto or Manual Customized value displayed -
Add Foot Air in FACE Mode Add foot air in face mode ON or OFF Customized value displayed -
Noise and Vibration Reduction Noise and vibration reduction ON or OFF Customized value displayed -
ECO MODE Cancel ECO drive mode cancel OFF or ON Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
COOL A/M Servo Targ Pls(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) target pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) target pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 326 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 186 (pulse)


for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction


COOL A/M Servo Actual Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) actual pulse


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) actual pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 326 (pulse)


for RHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 186 (pulse)


for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) system malfunction


COOL A/M Servo Targ Pls(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) target pulse


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) target pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 186 (pulse)


for RHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 326 (pulse)


for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction


COOL A/M Servo Actual Pulse(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) actual pulse


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) actual pulse


Min.: 128
Max.: 383
for LHD:
·

MAX COLD: 258 (pulse)

·

MAX HOT: 186 (pulse)


for RHD:
·

MAX COLD: 254 (pulse)

·

MAX HOT: 326 (pulse)


for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) system malfunction


A/O Damper FACE Pos(D)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) target pulse


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) target pulse


Min.: 128
Max.: 383
for LHD:
·

FACE1, 2: 258 (pulse)

·

FACE A/M: 275 (pulse)

·

B/L: 289 (pulse)

·

F/D: 335 (pulse)

·

FOOT-0: 345 (pulse)

·

Stay smell: 346 (pulse)

·

FOOT-D: 347 (pulse)

·

D/F: 348 (pulse)

·

FOOT-R, F: 349 (pulse)

·

DEF: 364 (pulse)


for RHD:
·

FACE1, 2: 254 (pulse)

·

FACE A/M: 237 (pulse)

·

B/L: 198 (pulse)

·

F/D: 177 (pulse)

·

Stay smell, FOOT-F: 166 (pulse)

·

FOOT-R: 165 (pulse)

·

DEF: 148 (pulse)


for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction


A/O Damper FACE Actual Pos(D)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) actual pulse


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) actual pulse


Min.: 128
Max.: 383
for LHD:
·

FACE1, 2: 258 (pulse)

·

FACE A/M: 275 (pulse)

·

B/L: 289 (pulse)

·

F/D: 335 (pulse)

·

FOOT-0: 345 (pulse)

·

Stay smell: 346 (pulse)

·

FOOT-D: 347 (pulse)

·

D/F: 348 (pulse)

·

FOOT-R, F: 349 (pulse)

·

DEF: 364 (pulse)


for RHD:
·

FACE1, 2: 254 (pulse)

·

FACE A/M: 237 (pulse)

·

B/L: 198 (pulse)

·

F/D: 177 (pulse)

·

Stay smell, FOOT-F: 166 (pulse)

·

FOOT-R: 165 (pulse)

·

DEF: 148 (pulse)


for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) system malfunction


A/O Damper FOOT/DEF Pos(D)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) target pulse


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) target pulse


Min.: 128
Max.: 383
for LHD:
·

FACE2: 258 (pulse)

·

FACE1: 267 (pulse)

·

FACE A/M: 283 (pulse)

·

B/L, FOOT-0, R, D: 292 (pulse)

·

Stay smell: 308 (pulse)

·

FOOT-F: 317 (pulse)

·

F/D: 328 (pulse)

·

D/F: 342 (pulse)

·

DEF: 365 (pulse)


for RHD:
·

FACE2: 254 (pulse)

·

FACE1: 245 (pulse)

·

FACE A/M: 229 (pulse)

·

B/L, FOOT-0, FOOT-R, FOOT-D: 220 (pulse)

·

Stay smell: 204 (pulse)

·

FOOT-F: 195 (pulse)

·

F/D: 184 (pulse)

·

DEF: 147 (pulse)


for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction


A/O Damper FOOT/DEF Act Pos(D)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) actual pulse


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) actual pulse


Min.: 128
Max.: 383
for LHD:
·

FACE2: 258 (pulse)

·

FACE1: 267 (pulse)

·

FACE A/M: 283 (pulse)

·

B/L, FOOT-0, R, D: 292 (pulse)

·

Stay smell: 308 (pulse)

·

FOOT-F: 317 (pulse)

·

F/D: 328 (pulse)

·

D/F: 342 (pulse)

·

DEF: 365 (pulse)


for RHD:
·

FACE2: 254 (pulse)

·

FACE1: 245 (pulse)

·

FACE A/M: 229 (pulse)

·

B/L, FOOT-0, FOOT-R, FOOT-D: 220 (pulse)

·

Stay smell: 204 (pulse)

·

FOOT-F: 195 (pulse)

·

F/D: 184 (pulse)

·

DEF: 147 (pulse)


for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (driver side MODE FOOT (for 3 Zone)) system malfunction


A/O Damper FACE Pos(P) No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) target pulse Min.: 128
Max.: 383
for LHD:
·

FACE1, 2: 254 (pulse)

·

FACE A/M: 237 (pulse)

·

B/L: 223 (pulse)

·

F/D: 177 (pulse)

·

FOOT-0: 167 (pulse)

·

Stay smell, FOOT-F: 166 (pulse)

·

FOOT-D: 165 (pulse)

·

FOOT-F, R: 163 (pulse)

·

DEF: 148 (pulse)


for RHD:
·

FACE1, FACE2: 258 (pulse)

·

FACE A/M: 275 (pulse)

·

B/L: 314 (pulse)

·

F/D: 335 (pulse)

·

Stay smell, FOOT-F: 346 (pulse)

·

FOOT-D: 346 (pulse)

·

D/F, FOOT-0, FOOTR: 347 (pulse)

·

DEF: 364 (pulse)


No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) system malfunction
(for 3 Zone)
A/O Damper FACE Actual Pos(P) No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) target pulse Min.: 128
Max.: 383
for LHD:
·

FACE1, 2: 254 (pulse)

·

FACE A/M: 237 (pulse)

·

B/L: 223 (pulse)

·

F/D: 177 (pulse)

·

FOOT-0: 167 (pulse)

·

Stay smell, FOOT-F: 166 (pulse)

·

FOOT-D: 165 (pulse)

·

FOOT-F, R: 163 (pulse)

·

DEF: 148 (pulse)


for RHD:
·

FACE1, FACE2: 258 (pulse)

·

FACE A/M: 275 (pulse)

·

B/L: 314 (pulse)

·

F/D: 335 (pulse)

·

Stay smell, FOOT-F: 346 (pulse)

·

FOOT-D: 346 (pulse)

·

D/F, FOOT-0, FOOTR: 347 (pulse)

·

DEF: 364 (pulse)


No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) system malfunction
(for 3 Zone)
A/O Damper FOOT/DEF Pos(P) No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) target pulse Min.: 128
Max.: 383
for LHD:
·

FACE1, 2: 254 (pulse)

·

FACE A/M: 237 (pulse)

·

B/L: 223 (pulse)

·

F/D: 177 (pulse)

·

FOOT-0: 167 (pulse)

·

Stay smell, FOOT-F: 166 (pulse)

·

FOOT-D: 165 (pulse)

·

FOOT-F, R: 163 (pulse)

·

DEF: 148 (pulse)


for RHD:
·

FACE2: 258 (pulse)

·

FACE1: 267 (pulse)

·

FACE A/M: 283 (pulse)

·

B/L, FOOT-0, FOOT-R, FOOT-D: 292 (pulse)

·

Stay smell: 308 (pulse)

·

FOOT-F: 317 (pulse)

·

F/D: 328 (pulse)

·

DEF: 365 (pulse)


No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) system malfunction
(for 3 Zone)
A/O Damper FOOT/DEF Act Pos(P) No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) actual pulse Min.: 128
Max.: 383
for LHD:
·

FACE1, 2: 254 (pulse)

·

FACE A/M: 237 (pulse)

·

B/L: 223 (pulse)

·

F/D: 177 (pulse)

·

FOOT-0: 167 (pulse)

·

Stay smell, FOOT-F: 166 (pulse)

·

FOOT-D: 165 (pulse)

·

FOOT-F, R: 163 (pulse)

·

DEF: 148 (pulse)


for RHD:
·

FACE2: 258 (pulse)

·

FACE1: 267 (pulse)

·

FACE A/M: 283 (pulse)

·

B/L, FOOT-0, FOOT-R, FOOT-D: 292 (pulse)

·

Stay smell: 308 (pulse)

·

FOOT-F: 317 (pulse)

·

F/D: 328 (pulse)

·

DEF: 365 (pulse)


No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) system malfunction
(for 3 Zone)
Air Mix Servo Targ Pls(F&R D) No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) target pulse Min.: 128
Max.: 383
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) system malfunction
A/M Servo Actual Pulse(F&R D) No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) actual pulse Min.: 128
Max.: 383
·

MAX COLD: 258 (pulse)

·

MAX HOT: 154 (pulse)


No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) system malfunction
Air Outlet Servo Pls (F&R D)
for LHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) target pulse


for RHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) target pulse


Min.: 128
Max.: 383
for LHD:
·

FACE1, A/M: 249 (pulse)

·

FACE2: 252 (pulse)

·

B/L: 266 (pulse)

·

FOOT-ALL: 274 (pulse)

·

F/D: 280 (pulse)

·

D/F: 286 (pulse)

·

DEF: 289 (pulse)


for RHD:
·

FACE1, A/M: 263 (pulse)

·

FACE2: 260 (pulse)

·

B/L: 249 (pulse)

·

FOOT-ALL: 238 (pulse)

·

F/D: 232 (pulse)

·

DEF: 289 (pulse)


for LHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction


for RHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction


A/O Servo Actual Pulse(F&R D)
for LHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) actual pulse


for RHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) actual pulse


Min.: 128
Max.: 383
for LHD:
·

FACE1, A/M: 249 (pulse)

·

FACE2: 252 (pulse)

·

B/L: 266 (pulse)

·

FOOT-ALL: 274 (pulse)

·

F/D: 280 (pulse)

·

D/F: 286 (pulse)

·

DEF: 289 (pulse)


for RHD:
·

FACE1, A/M: 263 (pulse)

·

FACE2: 260 (pulse)

·

B/L: 249 (pulse)

·

FOOT-ALL: 238 (pulse)

·

F/D: 232 (pulse)

·

DEF: 289 (pulse)


for LHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction


for RHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) system malfunction


A/O Damper DEF Pos(D Side)
for LHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) target pulse


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) target pulse


Min.: 128
Max.: 383
·

DEF, F/D, D/F: 242 (pulse)

·

FOOT-D: 331 (pulse)

·

FOOT-R, FOOT-F: 332 (pulse)

·

FACE, B/L, FOOT-0: 348 (pulse)


for LHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction


A/O Damper DEF Actual Pos(D)
for LHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) actual pulse


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) actual pulse


Min.: 128
Max.: 383
·

DEF, F/D, D/F: 242 (pulse)

·

FOOT-D: 331 (pulse)

·

FOOT-R, FOOT-F: 332 (pulse)

·

FACE, B/L, FOOT-0: 348 (pulse)


for LHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) system malfunction


Compressor Drive Check Compressor drive check OK or NG NG: Compressor does not drive
OK: Compressor drives
-
Glass Temperature Glass temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual glass temperature is displayed Not applicated
Glass Surroundings Temperature Glass surroundings temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual glass surroundings temperature is displayed Not applicated
Glass Humidity Glass humidity Min.: 0.00%
Max.: 100.00%
Actual glass humidity is displayed Not applicated
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Set Temperature (Rear) Rear side set temperature Min.: MAX COLD
Max.: MAX HOT
Rear side set temperature displayed -
Outside Air Mode Auto Switch Function Outside air mode auto switch function ON or OFF Customized value displayed -
Heater Valve Position Three-way valve actual position Min.: -14.0%
Max.: 113.5%
Three-way valve actual position -
S-FLOW Control Auto Function S-FLOW control auto function ON or OFF Customized value displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -
Refrigerant High Pressure History History of refigerant high pressure in the past Min.: 0
Max.: 255
Number of times refrigerant high pressure in the past displayed
HINT:

Clear history after check


High Voltage Electric Heater Inlet Coolant Temperature Sensor High voltage electric heater inlet temperature -327.68 to 327.67 °C (-557.82 to 621.81 °F) High voltage electric heater inlet temperature displayed -
High Voltage Electric Heater Outlet Coolant Temperature Sensor High voltage electric heater outlet temperature -327.68 to 327.67 °C (-557.82 to 621.81 °F) High voltage electric heater outlet temperature displayed -
High Voltage Electric Heater Target Electric Power High voltage electric heater target power 0 to 12750 W High voltage electric heater target power displayed -
High Voltage Electric Heater Consumption Electric Power High voltage electric heater actual power 0 to 12750 W High voltage electric heater actual power displayed -
High Voltage Electric Heater Overheat Detection Status Number of over heat at high voltage electric heater 0 to 3 Number of over heat at high voltage electric heater displayed -
Body Electrical > Power Integration No.2 > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
PTC Heater No.1 Input Signal Quick heater assembly input status OFF or ON OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates
-
PTC Heater No.2 Input Signal Quick heater assembly input status OFF or ON OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates
-
PTC Heater No.1 Output Signal Quick heater assembly output status OFF or ON OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates
-
PTC Heater No.2 Output Signal Quick heater assembly output status OFF or ON OFF: Quick heater assembly does not operate
ON: Quick heater assembly operates
-
PTC Heater No.1 Output Current Quick heater assembly current 0 to 65535 A 2 A or less -
PTC Heater No.2 Output Current Quick heater assembly current 0 to 65535 A 2 A or less -
Status of PTC Heater No.1 Fuse Quick heater assembly fuse Connect or Disconnect Connect: Fuse not shut off
Disconnect: Fuse shut off
-
Status of PTC Heater No.2 Fuse Quick heater assembly fuse Connect or Disconnect Connect: Fuse not shut off
Disconnect: Fuse shut off
-
PTC Heater No.1 Fuse Shut Off History Quick heater assembly fuse shut off history OFF or ON OFF: Fuse has no shut off history
ON: Fuse has shut off history
-
PTC Heater No.2 Fuse Shut Off History Quick heater assembly fuse shut off history OFF or ON OFF: Fuse has no shut off history
ON: Fuse has shut off history
-
Powertrain > EV > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Target FC Current (Filtered Value) FC stack outlet coolant temperature -40°C to 215.9 °C (-40°F to 421 °F) 50 to 85 °C (122 to 185 °F): After warming up -


ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Restrict Condition
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Compressor Target Speed Compressor with motor assembly Min.: 0
Max.: 7500
Perform this test when the ignition switch ON (READY)
Water Pump Water with motor pump assembly OFF/ON Perform this test when the following conditions are met:
·

Ignition switch ON (READY)

·

Air conditioning system is operated


Heater Active Level Quick heater assembly Min.: 0
Max.: 2
Perform this test when the following conditions are met:
·

Ignition switch ON (READY)

·

Air conditioning system is operated


Air Mix Servo Targ Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation


Min.: 128
Max.: 383
for LHD (for Dual):

Operates between 154 to 258 pulses


for LHD (for 3 Zone):

Operates between 254 to 358 pulses


for RHD:

Operates between 154 to 258 pulses


Air Mix Servo Targ Pulse(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation


Min.: 128
Max.: 383
for LHD:

Operates between 154 to 258 pulses


for RHD (for Dual):

Operates between 154 to 258 pulses


for RHD (for 3 Zone):

Operates between 254 to 358 pulses


Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 383
for LHD:

Operates between 258 to 290 pulses


for RHD:

Operates between 222 to 254 pulses


Cool A/M Servo Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side upper air mix) operation


Min.: 128
Max.: 383
for LHD:

Operates between 254 and 326 pulses


for RHD:

Operates between 186 to 258 pulses


Cool A/M Servo Pulse(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) operation


Min.: 128
Max.: 383
for LHD:

Operates between 186 and 258 pulses


for RHD:

Operates between 254 to 326 pulses


Face A/O Servo Pulse(D)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) operation


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FACE (for Dual)), (driver side MODE FACE (for 3 Zone)) operation


Min.: 128
Max.: 383
for LHD:

Operates between 258 and 364 pulses


for RHD:

Operates between 148 to 254 pulses


Foot A/O Servo Pulse(D)
for LHD:

No. 1 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (Driver side MODE FOOT (for 3 Zone)) operation


for RHD:

No. 3 air conditioning radiator damper servo sub-assembly (MODE FOOT (for Dual)), (Driver side MODE FOOT (for 3 Zone)) operation


Min.: 128
Max.: 383
for LHD:

Operates between 258 and 365 pulses


for RHD:

Operates between 147 to 254 pulses


Face A/O Servo Pulse(P) No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FACE) operation Min.: 128
Max.: 383
for LHD:

Operates between 147 and 254 pulses


for RHD:

Operates between 258 and 364 pulses


Foot A/O Servo Pulse(P) No. 6 air conditioning radiator damper servo sub-assembly (front passenger side MODE FOOT) operation Min.: 128
Max.: 383
for LHD:

Operates between 148 and 254 pulses


for RHD:

Operates between 258 and 365 pulses


A/M Servo Pulse(F&R D) No. 2 air conditioning radiator damper servo sub-assembly (air mix (rear)) operation Min.: 128
Max.: 383
Operates between 154 and 258 pulses
A/O Servo Pulse(F&R D)
for LHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) operation


for RHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE FACE/FOOT (rear)) operation


Min.: 128
Max.: 383
for LHD:

Operates between 249 and 289 pulses


for RHD:

Operates between 263 and 289 pulses


(for 3 Zone)
DEF A/O Servo Pulse(D)
for LHD:

No. 5 air conditioning radiator damper servo sub-assembly (MODE DEF) operation


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly (MODE DEF) operation


Min.: 128
Max.: 383
for LHD:

Operates between 249 and 289 pulses


for RHD:

Operates between 263 and 289 pulses


(for 3 Zone)
Heater Valve 3 way valve operation Close, Half, Open -
High Voltage Electric Heater High voltage electric heater operation 0 to 12750 Perform this test when the following conditions are met:
·

Blower switch: HI

·

Air conditioning system is operated