Home › Power Source / Network › POWER DISTRIBUTION › POWER INTEGRATION SYSTEM
RM37H0E _57 Power Source / Network _095301 POWER DISTRIBUTION _0455449 POWER INTEGRATION SYSTEM D

POWER DISTRIBUTION  POWER INTEGRATION SYSTEM  SYSTEM DESCRIPTION  


LOAD OPERATION OUTPUT


a.

Load is turned on or off according to the operation signals and switch signals from each ECU.



Load No. 1 Semiconductor Power Integration ECU (w/ PTC Heater) No. 2 Semiconductor Power Integration ECU

*: w/ Rear Fog Light

Headlight ECU sub-assembly LH ● -
Headlight ECU sub-assembly RH ● -
Stop light - ●
Rear taillight - ●
Rear fog light* - ●
Back-up light - ●
Rear defogger - ●

SEMICONDUCTOR FUSE FUNCTION


a.

When a malfunction current occurs during load operation, the current is shut off before the electrical lines emit smoke, and then load is turned off. After the current is shut off, the off condition is maintained until the operation signals or switch signals turn off.

B467146E02
2.792,2.615 3.5,2.823 0.708,0.208 10 false Maintained 4.323,2.615 5.031,2.823 0.708,0.208 10 false Maintained 1.135,2.448 1.448,2.646 0.313,0.198 10 false ON 1.083,2.813 1.542,3.01 0.458,0.198 10 false OFF 0.073,2.573 1.094,2.781 1.021,0.208 10 false Applicable Load 1.125,1.177 1.583,1.375 0.458,0.198 10 false Met 0.875,1.771 1.427,1.99 0.552,0.219 10 false Not met 0.073,1.448 1.354,1.646 1.281,0.198 10 false Output On Condition 3.688,2.104 4.177,2.323 0.49,0.219 10 false Cancel 5.198,2.104 5.688,2.323 0.49,0.219 10 false Cancel 1.583,0.521 2.094,0.719 0.51,0.198 10 false Normal 6.125,0.521 6.635,0.719 0.51,0.198 10 false Normal 3.531,0.521 4.323,0.708 0.792,0.188 10 false Overcurrent