PRECAUTION FOR SEMICONDUCTOR POWER INTEGRATION ECU
Do not remove or install the semiconductor power integration ECU with the negative (-) auxiliary battery terminal connected.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Some parts must be initialized and set when replacing or removing and installing parts.
Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>WORK PROCEDURE
Make sure that the semiconductor power integration ECU is not exposed to water, as it is not waterproof.
Some load is connected to a dedicated circuit to prevent overcurrent. Therefore, parts other than those specified for the vehicle may not be able to be used.
When replacing the semiconductor power integration ECU, the system may not operate normally if the same part number is not used.