COOLING  ROTARY VALVE  INSPECTION  


PROCEDURE

Hide 16A31 1.INSPECT FC COOLING WATER TEMPERATURE CONTROL VALVE

a.

Check the resistance.

i.
A340792C05
1.552,0.063 1.917,0.271 0.365,0.208 2.281,1.01 2.688,0.854 true 1.854,0.719 2.281,0.25 true 0.646,0.677 1.156,0.823 true 0.667,1.479 1.167,1.385 true 1.708,1.875 1.719,1.531 true 2.656,1.75 2.229,1.479 true 0.135,0.135 0.448,0.333 0.313,0.198 10 false *a 2.729,0.76 3.167,0.979 0.438,0.219 10 false WRA1 2.323,0.146 2.635,0.344 0.313,0.198 10 false B1 0.208,0.563 0.667,0.771 0.458,0.208 10 false WRA2 0.24,1.406 0.719,1.583 0.479,0.177 10 false WRB2 1.646,1.948 1.958,2.146 0.313,0.198 10 false B2 2.719,1.677 3.177,1.875 0.458,0.198 10 false WRB1 1.271,0.844 1.427,1.042 0.156,0.198 10 false 1 1.667,0.854 1.823,1.052 0.156,0.198 10 false 2 2.063,0.865 2.219,1.063 0.156,0.198 10 false 3 1.271,1.281 1.427,1.479 0.156,0.198 10 false 4 1.667,1.281 1.823,1.479 0.156,0.198 10 false 5 2.063,1.271 2.219,1.469 0.156,0.198 10 false 6 1.594,0.083 1.906,0.281 0.313,0.198 10 false B17
*a Component without harness connected
(FC Cooling Water Temperature Control Valve)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(B17)Location & Routing

Click Connector(B17)Engine Compartment>No. 2 Stack Wire>FC Cooling Water Temperature Control Valve

B17-5(B2) - B17-6(WRB1) 20°C (68°F) 18 to 22 Ω
B17-5(B2) - B17-4(WRB2) 20°C (68°F) 18 to 22 Ω
B17-2(B1) - B17-3(WRA1) 20°C (68°F) 18 to 22 Ω
B17-2(B1) - B17-1(WRA2) 20°C (68°F) 18 to 22 Ω



ii.

If the result is not as specified, replace the FC cooling water temperature control valve.