1.INSPECT FC COOLING WATER TEMPERATURE CONTROL VALVE
Check the resistance.
| *a | Component without harness connected
(FC Cooling Water Temperature Control Valve) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B17)Location & Routingewd_type=routing;type=c;code=B17 Click Connector(B17)Engine Compartment>No. 2 Stack Wire>FC Cooling Water Temperature Control Valveewd_type=component;type=c;code=B17;pinno=5,6,4,2,3,1 |
||
| B17-5(B2) - B17-6(WRB1) | 20°C (68°F) | 18 to 22 Ω |
| B17-5(B2) - B17-4(WRB2) | 20°C (68°F) | 18 to 22 Ω |
| B17-2(B1) - B17-3(WRA1) | 20°C (68°F) | 18 to 22 Ω |
| B17-2(B1) - B17-1(WRA2) | 20°C (68°F) | 18 to 22 Ω |
If the result is not as specified, replace the FC cooling water temperature control valve.