Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HV BATTERY
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0457184 HV BATTERY Y

HYBRID / BATTERY CONTROL  HV BATTERY  RECOVERY INSPECTION  


CAUTION / NOTICE / HINT

CAUTION:
·

When disposing of an EV supply battery aseembly, make sure to return it through an authorized collection agent who is capable of handling it safely. If the EV supply battery aseembly is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

·

Before returning the EV supply battery aseembly, make sure to perform a recovery inspection.

·

Accidents such as electric shock may result if the EV supply battery aseembly is disposed of improperly or abandoned.

Therefore, make sure to return all EV batteries through an authorized collection agent.

·

To reduce the risk of fire, EV batteries must not be stored in an area where they will be exposed to fire or high temperatures.

·

If the temperature of the EV supply battery aseembly is high, leave it until the temperature drops.



HINT:

In order to return the EV supply battery aseembly in a safe manner, discharge it as necessary. By performing a recovery inspection, whether discharging the EV supply battery aseembly will be required or not and the discharge method can be checked.


PROCEDURE

1.INSPECT FOR ELECTROLYTE LEAK
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.
C372179

Position the EV supply battery assembly as shown in the illustration and leave it for 5 minutes.


b.

Check that no electrolyte is leaking from the EV supply battery assembly.

OK:

There is no electrolyte leaking from the EV supply battery assembly.


CAUTION:
·

Perform this procedure in an area where the battery will not be exposed to fire.

·

Do not touch the EV supply battery assembly, unless absolutely necessary, as electrolyte may be leaking.



NOTICE:

If there is an electrolyte leak, make sure to wear insulated gloves and goggles and clean it using a piece of cloth. Do not leave electrolyte-contaminated cloths unattended. Dispose of them according to law or local regulations.



Result:
Result
OK
NG



OK

2.CHECK FOR DTCS

NG

DISCHARGING (WHEN USING THE SALT WATER SOLUTION)

2.CHECK FOR DTCS
a.

Check the previously recorded DTCs which resulted in replacement of the EV battery.

Result:
Result Proceed to
DTC record not available. A
The EV battery was replaced due to one of the DTCs listed in the following table. B
The EV battery was replaced due to a reason other than the DTCs listed in the following table. C


DTC No.
P1A6017
P31AA17
P0C3000
P31B300
P1C7D49



A

3.CHECK EV BATTERY VOLTAGE

B

5.EV BATTERY VISUAL CHECK

C

6.EV BATTERY CONNECTORS VISUAL CHECK
3.CHECK EV BATTERY VOLTAGE
CAUTION:

Wear insulated gloves.


a.
C372180C01
0.417,0.865 0.563,0.49 true 2.125,0.875 2.271,0.5 true 0.333,0.948 0.49,1.146 0.156,0.198 10 false B 2.042,0.958 2.198,1.156 0.156,0.198 10 false A 1.885,0.177 2.198,0.375 0.313,0.198 10 false *1 0.188,0.177 0.5,0.375 0.313,0.198 10 false *2
*1 No. 1 EV Battery Main Cable (A)
*2 No. 2 EV Battery Main Cable (B)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A - B Always Below 350.7 V


CAUTION:

Make sure not to cross the probes of the electrical tester.



Result:
Result
OK
NG



OK

4.INSULATION INSPECTION OF EV BATTERY

NG

6.EV BATTERY CONNECTORS VISUAL CHECK
4.INSULATION INSPECTION OF EV BATTERY
CAUTION:

Wear insulated gloves.


a.
C372181C01
0.406,0.833 0.552,0.49 true 2.115,0.833 2.26,0.49 true 2.906,3.156 2.75,3.156 2.75,3.156 2.625,3.01 true 0.333,0.906 0.49,1.104 0.156,0.198 10 false B 2.063,0.927 2.219,1.125 0.156,0.198 10 false A 1.927,0.198 2.156,0.396 0.229,0.198 10 false *1 0.167,0.198 0.396,0.396 0.229,0.198 10 false *2 2.979,3.083 3.208,3.281 0.229,0.198 10 true *a
*1 No. 1 EV Battery Main Cable (A)
*2 No. 2 EV Battery Main Cable (B)
*a Battery Outer Case


Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition
A - Battery Outer Case Always 1 MΩ or higher
B - Battery Outer Case Always 1 MΩ or higher



Result:
Result
OK
NG



OK

5.EV BATTERY VISUAL CHECK

NG

6.EV BATTERY CONNECTORS VISUAL CHECK
5.EV BATTERY VISUAL CHECK
CAUTION:

Wear insulated gloves.


a.

Check that the EV supply battery assembly is not deformed or damaged.

OK:

The EV supply battery assembly is not deformed or damaged.



Result:
Result
OK
NG



OK

RETURN EV BATTERY

NG

6.EV BATTERY CONNECTORS VISUAL CHECK
6.EV BATTERY CONNECTORS VISUAL CHECK
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Check that the orange connectors connected to the battery ECU assembly are not deformed or damaged.

OK:

The connectors are not deformed or damaged.



HINT:

If any of the connectors are damaged, a Li-ion battery discharger will not be able to be connected to the EV supply battery assembly. Soak the EV supply battery assembly in a saltwater solution to discharge it.


Result:
Result
OK
NG



OK

DISCHARGING (WHEN USING THE LI-ION BATTERY DISCHARGER)

NG

DISCHARGING (WHEN USING THE SALT WATER SOLUTION)