| *a | EV Control ECU | - | - |
| *1 | for RHD | *2 | for LHD |
The standard normal voltage between each pair of EV control ECU terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the EV control ECU terminal locations.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| A17-18 (NODD) - A17-4 (E1) | DC/DC operation | DC/DC converter operating normally | 5 to 7 V |
| DC/DC converter not operating normally | 2 to 4 V | ||
| DC/DC converter operation prohibited | 0.1 to 0.5 V | ||
| A17-13 (LIN3) - A17-4 (E1) | LIN communication signal
(A/C inverter, auxiliary battery) |
Ignition switch ON (READY) | Pulse generation
(Waveform 1) |
| A17-17 (VLO) - A17-4 (E1) | DC/DC operation monitor/voltage change signal | Ignition switch ON | Pulse generation
(Waveform 2) |
| A15-21 (MREL) - A17-4 (E1) | Main relay | Ignition switch ON | 11 to 14 V |
Oscilloscope waveforms
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (LIN communication signal (A/C inverter, auxiliary battery))
| Item | Content |
|---|---|
| Terminal | A17-13 (LIN3) - A17-4 (E1) |
| Equipment Setting | 2 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON (READY) |
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 2 (DC/DC operation monitor/voltage change signal)
| Item | Content |
|---|---|
| Terminal | A17-17 (VLO) - A17-4 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Ignition switch ON |
The waveform will vary depending on the content of the digital communication (digital signal).