Home › Power Source / Network › BATTERY / CHARGING › CHARGING SYSTEM
RM37H0E _57 Power Source / Network _097006 BATTERY / CHARGING _0461862 CHARGING SYSTEM U

BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECU  


A352214C11
0.427,0.354 0.875,0.604 0.448,0.25 2.042,0.354 2.396,0.583 0.354,0.229 3.438,0.365 3.792,0.594 0.354,0.229 4.802,0.365 5.156,0.594 0.354,0.229 1,0.354 1.448,0.604 0.448,0.25 5.844,0.354 6.292,0.604 0.448,0.25 6.406,0.354 6.854,0.604 0.448,0.25 0.479,0.396 0.938,0.594 0.458,0.198 10 false A14*1 2.104,0.396 2.563,0.594 0.458,0.198 10 false A15 4.854,0.406 5.313,0.604 0.458,0.198 10 false A17 5.875,0.396 6.333,0.594 0.458,0.198 10 false D15*1 3.49,0.396 3.948,0.594 0.458,0.198 10 false A16 1.052,0.396 1.51,0.594 0.458,0.198 10 false G14*2 0.063,0.042 0.521,0.24 0.458,0.198 10 false *a 6.49,0.385 6.948,0.583 0.458,0.198 10 false A8*1
*a EV Control ECU - -
*1 for RHD *2 for LHD


HINT:

The standard normal voltage between each pair of EV control ECU terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the EV control ECU terminal locations.


EV Control ECU
Terminal No. (Symbol) Terminal Description Condition Specified Condition
A17-18 (NODD) - A17-4 (E1) DC/DC operation DC/DC converter operating normally 5 to 7 V
DC/DC converter not operating normally 2 to 4 V
DC/DC converter operation prohibited 0.1 to 0.5 V
A17-13 (LIN3) - A17-4 (E1) LIN communication signal
(A/C inverter, auxiliary battery)
Ignition switch ON (READY) Pulse generation
(Waveform 1)
A17-17 (VLO) - A17-4 (E1) DC/DC operation monitor/voltage change signal Ignition switch ON Pulse generation
(Waveform 2)
A15-21 (MREL) - A17-4 (E1) Main relay Ignition switch ON 11 to 14 V

a.

Oscilloscope waveforms

HINT:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.


i.
A408014E01
0.25,1.51 0.708,1.708 0.458,0.198 10 false GND

Waveform 1 (LIN communication signal (A/C inverter, auxiliary battery))

Item Content
Terminal A17-13 (LIN3) - A17-4 (E1)
Equipment Setting 2 V/DIV., 20 ms./DIV.
Condition Ignition switch ON (READY)

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).



ii.
A141395E12
3.104,0.99 3.417,1.229 0.313,0.24 10 GND

Waveform 2 (DC/DC operation monitor/voltage change signal)

Item Content
Terminal A17-17 (VLO) - A17-4 (E1)
Equipment Setting 5 V/DIV., 50 ms./DIV.
Condition Ignition switch ON

HINT:

The waveform will vary depending on the content of the digital communication (digital signal).