Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0453477 HYBRID BATTERY SYSTEM D

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  DIAGNOSIS SYSTEM  


DESCRIPTION


a.

The battery ECU assembly has a self-diagnosis system. If the ECU, hybrid control system, or a component is not working properly, the ECU records the conditions that relate to the fault. The ECU also illuminates the master warning in the combination meter assembly and provides other appropriate messages on the multi-information display, such as the HV system warning message, EV battery warning message, or discharge warning message.



2 TRIP DETECTION LOGIC


Following is the description for storage of DTC using "2 trip detection logic".

When a malfunction is first detected, the malfunction is temporarily stored in the battery ECU assembly memory (1st trip). If the same malfunction is detected during the next drive cycle, the MIL is illuminated (2nd trip).



FREEZE FRAME DATA


The battery ECU assembly records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was moving or stationary, whether the FC system was warmed up or not, as well as other data recorded at the time of a malfunction.



AUXILIARY BATTERY VOLTAGE


Standard Voltage:
Switch Condition Specified Condition
Ignition switch ON 11 to 14 V


If voltage is below 11 V, replace or recharge the auxiliary battery.

NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART