Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0453477 HYBRID BATTERY SYSTEM U

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM  VEHICLE BEHAVIOR CHART  


VEHICLE BEHAVIOR CHART


a.

Vehicle behavior categorized by DTC

If a DTC is output, the vehicle behaves as follows.

DTC No. Detection Item Vehicle Behavior when DTC is Output
P056014 System Voltage (BATT) Circuit Short to Ground or Open
·

Reduced output power

·

FC system not stopped


P060629 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid
·

Reduced output power

·

FC system not stopped


P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
·

Reduced output power

·

FC system not stopped


P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
·

Reduced output power

·

FC system not stopped


P060A87 Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message
·

Reduced output power

·

FC system not stopped


P060B16 Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold
·

Reduced output power

·

FC system not stopped


P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
·

Reduced output power

·

FC system not stopped


P062F46 Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure Reduced output power
P0A1D94 Hybrid/EV Powertrain Control Module Unexpected Operation FC system stopped
P0A8100 Hybrid/EV Battery Cooling Fan 1 Control Circuit High Normal driving
P0A8111 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground Normal driving
P0A8115 Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open Normal driving
P0A814B Hybrid/EV Battery Cooling Fan 1 Over Temperature Normal driving
P0A8196 Hybrid/EV Battery Cooling Fan 1 Component Internal Failure Normal driving
P0A8198 Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature Normal driving
P0A9563 High Voltage Fuse Accumulated Load History Reduced output power
P0A9B11 Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground Normal driving
P0A9B15 Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open Normal driving
P0A9B1C Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range Normal driving
P0A9B2A Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range Normal driving
P0AAC11 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground Normal driving
P0AAC15 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open Normal driving
P0ABF11 Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground
·

Reduced output power

·

FC system not stopped


P0ABF15 Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open
·

Reduced output power

·

FC system not stopped


P0ABF28 Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure
·

Reduced output power

·

FC system not stopped


P0ABF2A Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range
·

Reduced output power

·

FC system not stopped


P0AC511 Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground Normal driving
P0AC515 Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open Normal driving
P0AC51C Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range Normal driving
P0AC52A Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range Normal driving
P0ACA11 Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground Normal driving
P0ACA15 Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open Normal driving
P0ACA1C Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range Normal driving
P0ACA2A Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range Normal driving
P0AE811 Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground Normal driving
P0AE815 Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open Normal driving
P0AE81C Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range Normal driving
P0AE82A Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range Normal driving
P0B0E11 Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground
·

Reduced output power

·

FC system not stopped


P0B0E15 Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open
·

Reduced output power

·

FC system not stopped


P0B1362 Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure
·

Reduced output power

·

FC system not stopped


P0BC211 Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground Normal driving
P0BC215 Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open Normal driving
P0BC21C Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range Normal driving
P0BC22A Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range Normal driving
P0C3000 Hybrid/EV Battery State of Charge High
·

FC always stopped

·

Greatly reduced output power

·

A driving range is limited


P0C3311 Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground Normal driving
P0C3315 Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open Normal driving
P0C331C Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range Normal driving
P0C332A Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range Normal driving
P0E2D00 Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance
·

Reduced output power

·

FC system not stopped


P1A001C Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range
·

Reduced output power

·

FC system not stopped


P1A6017 Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold
·

Reduced output power

·

FC system not stopped


P1A6116 Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold
·

Reduced output power

·

FC system not stopped


P1A8000 Hybrid/EV Battery Stack 1 Delta SOC High Reduced output power
P1A8100 Hybrid/EV Battery Stack 1 Delta SOC High (Extreme)
·

Reduced output power

·

FC system not stopped


P1A8500 Hybrid/EV Battery Stack 2 Delta SOC High Reduced output power
P1A8600 Hybrid/EV Battery Stack 2 Delta SOC High (Extreme)
·

Reduced output power

·

FC system not stopped


P1AFC00 System Voltage (AM) Circuit Voltage Below Threshold
·

Reduced output power

·

FC system not stopped


P1AFD00 Flying Capacitor Circuit Voltage Out of Range
·

Reduced output power

·

FC system not stopped


P1AFD1C Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range
·

Reduced output power

·

FC system not stopped


P1AFF00 Hybrid/EV Battery ECU Multiple Reset
·

Reduced output power

·

FC system not stopped


P1C8549 High Voltage Power Resource Internal Electronic Failure FC system stopped
P1C9F11 Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground Normal driving
P1C9F15 Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open Normal driving
P1C9F1C Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range Normal driving
P1CBB12 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery
·

Reduced output power

·

FC system not stopped


P1CBB14 Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open
·

Reduced output power

·

FC system not stopped


P1CC81E Hybrid/EV Battery Stack 1 Voltage Difference Out of Range
·

Reduced output power

·

FC system not stopped


P1CC91E Hybrid/EV Battery Stack 2 Voltage Difference Out of Range
·

Reduced output power

·

FC system not stopped


P300000 Hybrid/EV Battery Discharge Control Malfunction FC system stopped
P300016 Hybrid/EV Battery Control System Circuit Voltage Below Threshold FC system stopped
P30004B Hybrid/EV Battery Control System Over Temperature FC system stopped
P301A1C Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range
·

Reduced output power

·

FC system not stopped


P306562 Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure Normal driving
P306A62 Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure Normal driving
P31AA17 Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold
·

Reduced output power

·

FC system not stopped


P31AB16 Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold
·

Reduced output power

·

FC system not stopped


P31B300 Hybrid/EV Battery Voltage High
·

Reduced output power

·

FC system not stopped


P31B400 Extreme Hybrid/EV Battery Charging Current FC system stopped
P31B549 Hybrid/EV Battery Internal Electronic Failure FC system stopped
P33DA1E Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range
·

Reduced output power

·

FC system not stopped


P33DB1E Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range
·

Reduced output power

·

FC system not stopped


P33E01B Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold
·

Reduced output power

·

FC system not stopped


P33E11B Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold
·

Reduced output power

·

FC system not stopped


P33EC16 (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold
·

Reduced output power

·

FC system not stopped


P33ED16 (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold
·

Reduced output power

·

FC system not stopped


U029387 Lost Communication with Hybrid/EV Powertrain Control Module Missing Message Normal driving
U115087 Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message
·

Reduced output power

·

FC system not stopped




b.

Relationship between the above and the multi-information display

Multi-information Display Vehicle Behavior
Visit Your Dealer Normal driving
Driving:

FCV System Stopped Stop in a Safe Place


Stop:

Shift to P See Owner's Manual


FC system stopped
Driving:

Vehicle is Unavailable Stop in a Safe Place


Stop:

Shift to P See Owner's Manual


1.

Normal driving

2.

When malfunction continues

-

FC system stopped



Driving:
·

Stop in a safe place See owner's manual

·

Stop in a safe place within "○" km


Stop:

Shift to P See Owner's Manual


A driving range is limited
Reduced Output Power Visit Your Dealer Reduced output power
Greatly Reduced Output Power Visit Your Dealer Greatly reduced output power
Driving:

Reduced Output Power Avoid Shifting to N


Stop:

Avoid Shifting to N Visit Your Dealer


·

Reduced output power

·

FC system not stopped



"○": Varies depending on the remaining driving range.