CHECK FREEZE FRAME DATA
The EV control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. Freeze frame data can help determine the vehicle conditions when the malfunction occurred and help duplicate conditions when troubleshooting.
Select a DTC in order to display its freeze frame data.
LIST OF FREEZE FRAME DATA
| Tester Display | Measurement Item | Range |
|---|---|---|
| Starter Switch Signal | Starter ON or OFF signal | ON or OFF |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 127.5% |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure (Total braking torque) | Min.: -4096 Nm, Max.: 4095.87 Nm |
| Shift Position | Current shift state | P, R, N, D or B |
| Shift Position (Meter) | Shift position of meter display | Not Displayed, P, R, N, D or B |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | ON or OFF |
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096 Nm, Max.: 4095.87 Nm |
| P Control Request Status | Shift control actuator assembly operation request | No Request, Lock(Normal), Unlock(Normal), Lock(Abnormal) or Unlock(Abnormal) |
| P Control Status | Shift state park (P) status | Lock Position (Normal), Lock Position (Abnormal), Indefinite Position (Normal), Indefinite Position (Abnormal), Unlock Position (Normal) or Unlock Position (Abnormal) |
| Target P Position | Target shift position of shift control actuator assembly | Unlock, Incertitude or Lock |
| P Position Status | Park (P) shift state status | Unlock, Incertitude or Lock |
| P Position Status before Last | Previous park (P) shift state status | Unlock, Incertitude or Lock |
| Parking Lock Motor Position | Shift control actuator assembly position | -32768 to 32767 |
| Parking Lock Motor Revolution | Shift control actuator assembly rotation speed | -32768 to 32767 rpm |
| Parking Lock Motor Rotation Direction | Shift control actuator assembly operating direction | Unlock, Incertitude or Lock |
| Parking Lock Motor Current Sensor Voltage | Shift control actuator assembly sensor voltage | Min.: 0 V, Max.: 4.99 V |
| Fail Safe History (Parking Lock Motor Inoperative) | Shift control actuator assembly malfunction fail-safe control history | ON or OFF |
| W Phase Parking Lock Motor Current-Carrying Status | W phase current-carrying status | ON or OFF |
| V Phase Parking Lock Motor Current-Carrying Status | V phase current-carrying status | ON or OFF |
| U Phase Parking Lock Motor Current-Carrying Status | U phase current-carrying status | ON or OFF |
| W Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (W phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V |
| V Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (V phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V |
| U Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (U phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V |
| Parking Lock Motor Main Relay Status | Operation state of the main relay for motor operation when in non-backup mode | ON or OFF |
| Parking Lock Motor Backup Relay Status | Operation state of the main relay for motor operation when in backup mode | ON or OFF |
| Abnormality Informing Status | Malfunction information status | ON or OFF |
| P Position Change Delayed History | History of park (P) state change delay malfunction | ON or OFF |
| Meter Display Request (P Position Switch ON when Running) | Status of P position switch rejection notification | ON or OFF |
| Meter Display Request (Shift N Operation when Running) | Status of change to neutral (N) shift status message | ON or OFF |
| Meter Display Request (Shift Operation Rejection) | Status of shift status change rejection message | 0 to 255 |
| Identifying Signal of Shift R/D Operation during Ready OFF | Certification ECU notice request (Shift lever moved to R or D when ignition switch not ON (READY)) | ON or OFF |
| Lock Position Learning Value | Learned value of lock position | -32768 to 32767 |
| Unlock Position Learning Value | Unlock position learning value | Min.: -32768, Max.: 32767 |
| Complete of Learn Unlock Position | Completion of unlock position learning | OK or NG |
| Complete of Detect Unlock Position | Completion of detecting unlock position | OK or NG |
| Complete of Learn Lock Position | Completion of lock position learning | OK or NG |
| Complete of Detect Lock Position | Completion of detecting lock position | OK or NG |
| Complete of Initially Drive Parking Lock Control | Initial drive control completed | OK or NG |
| P Position Automatic Change Request | P position automatic change request | ON or OFF |
| Limiting Driving Force Request from Transmission Control System | Drive torque limit request status from P position control to EV system | ON or OFF |
| SP1 Vehicle Speed | Vehicle speed (SP1) | Min.: 0 km/h (0 mph), Max.: 655.35 km/h (407.23 mph) |
| ACC Signal (Gear Shift Control Module) | ACC status | ON or OFF |
| ACC Status (Gear Shift Control Module) | ACC judgment status used for control | ON or OFF |
| IGCT Signal Status (Gear Shift Control Module) | IGCT signal status | ON or OFF |
| IG2 Signal Status (Gear Shift Control Module) | IG2 signal status | ON or OFF |
| IG Status (Gear Shift Control Module) | IG judgment status used for control | ON or OFF |
| BATT Voltage for Gear Shift Control Module | Auxiliary battery voltage | 0 to 79.99 V |
| Sub Battery Module Voltage | Shift control supply module assembly voltage | 0 to 79.99 V |
| Gear Shift Control Module Power Supply Voltage | ECU voltage | 0 to 79.99 V |
| Sub Battery Module Backup Status (Gear Shift Control Module) | Shift control supply backup status | Gear Shift Control Module Starting Request, Sub Battery Module Fail Safe, Backup Mode of Low SOC, Backup Mode of Normal or No Backup Mode |
| Backup Request from Sub Battery Module to Gear Shift Control Module | Shift control ECU to shift control supply backup request status | Backup Stop Request, Fail Safe, Backup Request or No Request |
| Backup Relay Status | Backup light relay operation status | ON or OFF |
| Fail Safe Status (Gear Shift Control Module) | Fail safe status | Unknown, ON or OFF |
| Shift Position Indicator Supply Voltage (Gear Shift Control Module) | Voltage value of power supplied to shift indicator and P switch connected to shift control ECU | Min.: 0 V, Max.:79.99 V |
| Shift Position Indicator Power Supply Output Status | Shift indicator power supply output status | ON or OFF |
| Shift Position (Current Position) | Shift lever actual position (judgment value) | Home, R, N, D, B/M/S or Not Available |
| Shift Sensor Status | Shift lever position sensor malfunction status | Normal, Abnormal or Abnormal (Extreme) |
| Shift Sensor Voltage (VSI1) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI2) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI3) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage (VSI4) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage 1 (Gear Shift Control Module) | Shift lever position sensor voltage | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage 2 (Gear Shift Control Module) | Shift lever position sensor voltage | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage 3 (Gear Shift Control Module) | Shift lever position sensor voltage | Min: 0 V, Max: 4.99 V |
| Shift Sensor Voltage 4 (Gear Shift Control Module) | Shift lever position sensor voltage | Min: 0 V, Max: 4.99 V |
| M or S Shift Position Indicator Turn On Request | Shift position indicator (shift state brake (Br)) illumination status | ON or OFF |
| D Shift Position Indicator Turn On Request | Shift position indicator (shift state drive (D)) illumination status | ON or OFF |
| N Shift Position Indicator Turn On Request | Shift position indicator (shift state neutral (N)) illumination status | ON or OFF |
| R Shift Position Indicator Turn On Request | Shift position indicator (shift state reverse (R)) illumination status | ON or OFF |
| P Shift Position Indicator Turn On Request | Shift position indicator (shift state park (P)) illumination status | ON or OFF |
| Parking Lock Motor Supply Current Limit Status | Limited current circuit activated or deactivated | ON or OFF |
| P Position Switch Terminal Voltage (Gear Shift Control Module) | P position switch terminal voltage | Min: 0 V, Max: 4.99 V |
| Stop Light Switch (Gear Shift Control Module) | Stop light switch status | ON or OFF |
| P Position Switch Signal Voltage (Gear Shift Control Module) | P position switch signal voltage | Min: 0 V, Max: 4.99 V |