Home › Drivetrain › Q710 (HYBRID TRANSMISSION / TRANSAXLE) › ELECTRONIC SHIFT LEVER SYSTEM
RM37H0E _52 Drivetrain _093826 Q710 HYBRID TRANSMISSION / TRANSAXLE _0454877 ELECTRONIC SHIFT LEVER SYSTEM D

Q710 HYBRID TRANSMISSION / TRANSAXLE  ELECTRONIC SHIFT LEVER SYSTEM  FREEZE FRAME DATA  


CHECK FREEZE FRAME DATA


HINT:

The EV control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. Freeze frame data can help determine the vehicle conditions when the malfunction occurred and help duplicate conditions when troubleshooting.


a.

Select a DTC in order to display its freeze frame data.

Powertrain > EV > Trouble Codes
50001 397


LIST OF FREEZE FRAME DATA


Powertrain > EV
Tester Display Measurement Item Range
Starter Switch Signal Starter ON or OFF signal ON or OFF
Accelerator Position Accelerator pedal depressed angle Min.: 0.0%, Max.: 127.5%
Master Cylinder Control Torque Braking torque equivalent to master cylinder brake fluid pressure (Total braking torque) Min.: -4096 Nm, Max.: 4095.87 Nm
Shift Position Current shift state P, R, N, D or B
Shift Position (Meter) Shift position of meter display Not Displayed, P, R, N, D or B
Shift Switch Status (N,P Position) Shift position status (N or P position) ON or OFF
Request Motor Regenerative Brake Torque Requested motor (MG2) regenerative braking torque Min.: -4096 Nm, Max.: 4095.87 Nm
P Control Request Status Shift control actuator assembly operation request No Request, Lock(Normal), Unlock(Normal), Lock(Abnormal) or Unlock(Abnormal)
P Control Status Shift state park (P) status Lock Position (Normal), Lock Position (Abnormal), Indefinite Position (Normal), Indefinite Position (Abnormal), Unlock Position (Normal) or Unlock Position (Abnormal)
Target P Position Target shift position of shift control actuator assembly Unlock, Incertitude or Lock
P Position Status Park (P) shift state status Unlock, Incertitude or Lock
P Position Status before Last Previous park (P) shift state status Unlock, Incertitude or Lock
Parking Lock Motor Position Shift control actuator assembly position -32768 to 32767
Parking Lock Motor Revolution Shift control actuator assembly rotation speed -32768 to 32767 rpm
Parking Lock Motor Rotation Direction Shift control actuator assembly operating direction Unlock, Incertitude or Lock
Parking Lock Motor Current Sensor Voltage Shift control actuator assembly sensor voltage Min.: 0 V, Max.: 4.99 V
Fail Safe History (Parking Lock Motor Inoperative) Shift control actuator assembly malfunction fail-safe control history ON or OFF
W Phase Parking Lock Motor Current-Carrying Status W phase current-carrying status ON or OFF
V Phase Parking Lock Motor Current-Carrying Status V phase current-carrying status ON or OFF
U Phase Parking Lock Motor Current-Carrying Status U phase current-carrying status ON or OFF
W Phase Parking Lock Motor Terminal Voltage Shift control actuator assembly (parking lock motor (W phase terminal voltage)) AD voltage (ECU recognized value) Min.: 0 V, Max.: 4.99 V
V Phase Parking Lock Motor Terminal Voltage Shift control actuator assembly (parking lock motor (V phase terminal voltage)) AD voltage (ECU recognized value) Min.: 0 V, Max.: 4.99 V
U Phase Parking Lock Motor Terminal Voltage Shift control actuator assembly (parking lock motor (U phase terminal voltage)) AD voltage (ECU recognized value) Min.: 0 V, Max.: 4.99 V
Parking Lock Motor Main Relay Status Operation state of the main relay for motor operation when in non-backup mode ON or OFF
Parking Lock Motor Backup Relay Status Operation state of the main relay for motor operation when in backup mode ON or OFF
Abnormality Informing Status Malfunction information status ON or OFF
P Position Change Delayed History History of park (P) state change delay malfunction ON or OFF
Meter Display Request (P Position Switch ON when Running) Status of P position switch rejection notification ON or OFF
Meter Display Request (Shift N Operation when Running) Status of change to neutral (N) shift status message ON or OFF
Meter Display Request (Shift Operation Rejection) Status of shift status change rejection message 0 to 255
Identifying Signal of Shift R/D Operation during Ready OFF Certification ECU notice request (Shift lever moved to R or D when ignition switch not ON (READY)) ON or OFF
Lock Position Learning Value Learned value of lock position -32768 to 32767
Unlock Position Learning Value Unlock position learning value Min.: -32768, Max.: 32767
Complete of Learn Unlock Position Completion of unlock position learning OK or NG
Complete of Detect Unlock Position Completion of detecting unlock position OK or NG
Complete of Learn Lock Position Completion of lock position learning OK or NG
Complete of Detect Lock Position Completion of detecting lock position OK or NG
Complete of Initially Drive Parking Lock Control Initial drive control completed OK or NG
P Position Automatic Change Request P position automatic change request ON or OFF
Limiting Driving Force Request from Transmission Control System Drive torque limit request status from P position control to EV system ON or OFF
SP1 Vehicle Speed Vehicle speed (SP1) Min.: 0 km/h (0 mph), Max.: 655.35 km/h (407.23 mph)
ACC Signal (Gear Shift Control Module) ACC status ON or OFF
ACC Status (Gear Shift Control Module) ACC judgment status used for control ON or OFF
IGCT Signal Status (Gear Shift Control Module) IGCT signal status ON or OFF
IG2 Signal Status (Gear Shift Control Module) IG2 signal status ON or OFF
IG Status (Gear Shift Control Module) IG judgment status used for control ON or OFF
BATT Voltage for Gear Shift Control Module Auxiliary battery voltage 0 to 79.99 V
Sub Battery Module Voltage Shift control supply module assembly voltage 0 to 79.99 V
Gear Shift Control Module Power Supply Voltage ECU voltage 0 to 79.99 V
Sub Battery Module Backup Status (Gear Shift Control Module) Shift control supply backup status Gear Shift Control Module Starting Request, Sub Battery Module Fail Safe, Backup Mode of Low SOC, Backup Mode of Normal or No Backup Mode
Backup Request from Sub Battery Module to Gear Shift Control Module Shift control ECU to shift control supply backup request status Backup Stop Request, Fail Safe, Backup Request or No Request
Backup Relay Status Backup light relay operation status ON or OFF
Fail Safe Status (Gear Shift Control Module) Fail safe status Unknown, ON or OFF
Shift Position Indicator Supply Voltage (Gear Shift Control Module) Voltage value of power supplied to shift indicator and P switch connected to shift control ECU Min.: 0 V, Max.:79.99 V
Shift Position Indicator Power Supply Output Status Shift indicator power supply output status ON or OFF
Shift Position (Current Position) Shift lever actual position (judgment value) Home, R, N, D, B/M/S or Not Available
Shift Sensor Status Shift lever position sensor malfunction status Normal, Abnormal or Abnormal (Extreme)
Shift Sensor Voltage (VSI1) (Gear Shift Control Module) Shift lever position sensor signal input voltage (AD value) Min: 0 V, Max: 4.99 V
Shift Sensor Voltage (VSI2) (Gear Shift Control Module) Shift lever position sensor signal input voltage (AD value) Min: 0 V, Max: 4.99 V
Shift Sensor Voltage (VSI3) (Gear Shift Control Module) Shift lever position sensor signal input voltage (AD value) Min: 0 V, Max: 4.99 V
Shift Sensor Voltage (VSI4) (Gear Shift Control Module) Shift lever position sensor signal input voltage (AD value) Min: 0 V, Max: 4.99 V
Shift Sensor Voltage 1 (Gear Shift Control Module) Shift lever position sensor voltage Min: 0 V, Max: 4.99 V
Shift Sensor Voltage 2 (Gear Shift Control Module) Shift lever position sensor voltage Min: 0 V, Max: 4.99 V
Shift Sensor Voltage 3 (Gear Shift Control Module) Shift lever position sensor voltage Min: 0 V, Max: 4.99 V
Shift Sensor Voltage 4 (Gear Shift Control Module) Shift lever position sensor voltage Min: 0 V, Max: 4.99 V
M or S Shift Position Indicator Turn On Request Shift position indicator (shift state brake (Br)) illumination status ON or OFF
D Shift Position Indicator Turn On Request Shift position indicator (shift state drive (D)) illumination status ON or OFF
N Shift Position Indicator Turn On Request Shift position indicator (shift state neutral (N)) illumination status ON or OFF
R Shift Position Indicator Turn On Request Shift position indicator (shift state reverse (R)) illumination status ON or OFF
P Shift Position Indicator Turn On Request Shift position indicator (shift state park (P)) illumination status ON or OFF
Parking Lock Motor Supply Current Limit Status Limited current circuit activated or deactivated ON or OFF
P Position Switch Terminal Voltage (Gear Shift Control Module) P position switch terminal voltage Min: 0 V, Max: 4.99 V
Stop Light Switch (Gear Shift Control Module) Stop light switch status ON or OFF
P Position Switch Signal Voltage (Gear Shift Control Module) P position switch signal voltage Min: 0 V, Max: 4.99 V