DATA LIST
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurement is performed. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the "Normal Condition" range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
According to the display on the GTS, read the Data List.
When reading the Data List, first determine which items need to be monitored before proceeding. Attempting to view all of the data may result in a delayed, inaccurate inspection.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Starter Switch Signal | Starter ON or OFF signal | ON or OFF | ON: Starter ON | - |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0%, Max.: 127.5% | 100%: Accelerator pedal fully depressed
0%: Accelerator pedal released |
Accelerator pedal sensor assembly |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure (Total braking torque) | Min.: -4096 Nm, Max.: 4095.87 Nm | Brake pedal depressed: Changes with the brake pedal pressure | Master cylinder brake fluid pressure control torque = hydraulic brake control torque + regenerative brake torque
Master cylinder pressure sensor |
| Shift Position | Current shift state | P, R, N, D or B | Matches currently selected shift state | When the value of Shift Position (Meter) is "Not Displayed" and the value of Shift Position is "N", the actual shift position cannot be determined and the parking lock may be engaged. |
| Shift Position (Meter) | Shift position of meter display | Not Displayed, P, R, N, D or B | Matches currently selected shift state | - |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | ON or OFF | ON: Shift state park (P) or neutral (N) | - |
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096 Nm, Max.: 4095.87 Nm | While braking: Varies depending on vehicle operation conditions | When regenerative braking is being performed, current flows from the motor (MG2) to charge the EV supply battery and braking torque is generated.
Electronically controlled brake system |
| P Control Request Status | Shift control actuator assembly operation request | No Request, Lock(Normal), Unlock(Normal), Lock(Abnormal) or Unlock(Abnormal) | No Request: Ignition switch ON, shift change has not been performed | - |
| P Control Status | Shift state park (P) status | Lock Position(Normal), Lock Position(Abnormal), Indefinite Position(Normal), Indefinite Position(Abnormal), Unlock Position(Normal) or Unlock Position(Abnormal) | Lock Position(Normal): Ignition switch ON and shift state park (P) selected | The control (obtains default operation position of shift actuator) performs after turning the ignition switch to ON. Therefore, perform the check after the control (obtains default operation position of shift actuator) is completed (after turning the ignition switch to ON and approximately 10 seconds elapse). |
| Parking Lock Motor Current Sensor Voltage | Shift control actuator assembly sensor voltage | Min: 0 V, Max: 4.99 V | - | - |
| W Phase Parking Lock Motor Current-Carrying Status | W phase current-carrying status | ON or OFF | ON: W phase current flows
OFF: W phase current does not flow |
Shift control actuator assembly [parking lock motor (MWA)] signal circuit |
| V Phase Parking Lock Motor Current-Carrying Status | V phase current-carrying status | ON or OFF | ON: V phase current flows
OFF: V phase current does not flow |
Shift control actuator assembly [parking lock motor (MVA)] signal circuit |
| U Phase Parking Lock Motor Current-Carrying Status | U phase current-carrying status | ON or OFF | ON: U phase current flows
OFF: U phase current does not flow |
Shift control actuator assembly [parking lock motor (MUA)] signal circuit |
| W Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (W phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V | 1 to 2 V: Ignition switch ON (when parking lock motor is not operating)
0 to 2 V: Ignition switch ON (when parking lock motor is operating) |
Shift control actuator assembly [parking lock motor (MWA)] signal circuit |
| V Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (V phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V | 1 to 2 V: Ignition switch ON (when parking lock motor is not operating)
0 to 2 V: Ignition switch ON (when parking lock motor is operating) |
Shift control actuator assembly [parking lock motor (MVA)] signal circuit |
| U Phase Parking Lock Motor Terminal Voltage | Shift control actuator assembly (parking lock motor (U phase terminal voltage)) AD voltage (ECU recognized value) | Min.: 0 V, Max.: 4.99 V | 1 to 2 V: Ignition switch ON (when parking lock motor is not operating)
0 to 2 V: Ignition switch ON (when parking lock motor is operating) |
Shift control actuator assembly [parking lock motor (MUA)] signal circuit |
| Parking Lock Motor Main Relay Status | Operation state of the main relay for motor operation when in non-backup mode | ON or OFF | ON: P CON MTR relay on
OFF: P CON MTR relay off |
- |
| Parking Lock Motor Backup Relay Status | Operation state of the main relay for motor operation when in backup mode | ON or OFF | ON: Shift control supply on
OFF: Shift control supply off |
- |
| Abnormality Informing Status | Malfunction information status | ON or OFF | ON: Malfunction occurring in this system
OFF: Malfunction not occurring in this system |
- |
| Lock Position Learning Value | Learned value of lock position | Min.: -32768, Max.: 32767 | - | - |
| Unlock Position Learning Value | Learned value of unlock position | Min.: -32768, Max.: 32767 | - | - |
| Complete of Learn Unlock Position | Completion of unlock position learning | OK or NG | OK: Ignition switch ON, park (P) selected → neutral (N) selected and number of trips after learning is less than 3 or ignition switch ON and number of trips after learning is 3 or more
NG: Ignition switch ON, a shift state other than park (P) has not been selected and number of trips after learning is less than 3 |
·
Learning: Ignition switch ON, Park (P) selected → Neutral (N) selected ·
Learning will not complete if neutral (N) has not been selected even if number of trips is 3 or more |
| Complete of Detect Unlock Position | Completion of detecting unlock position | OK or NG | OK: Ignition switch ON, park (P) selected → neutral (N) selected and number of trips after learning is less than 3
NG: Ignition switch ON and number of trips after learning is 3 or more |
- |
| Complete of Learn Lock Position | Completion of lock position learning | OK or NG | OK: Ignition switch ON | - |
| Complete of Detect Lock Position | Completion of detecting lock position | OK or NG | OK: Ignition switch ON | - |
| Complete of Initially Drive Parking Lock Control | Initial drive control completed | OK or NG | OK: Ignition switch ON | - |
| Auxiliary Battery Voltage Low History (P Lock Operate) | History of low voltage during shift control actuator assembly operation | ON or OFF | ON: History exists
OFF: No history |
- |
| Number of Trip after Auxiliary Battery Voltage Low (P Lock Operate) | Number of trips since low voltage detected during shift control actuator assembly operation | Min: 0, Max: 255 | - | - |
| P Position Automatic Change Request | P position automatic change request | ON or OFF | OFF: Ignition switch ON | - |
| Limiting Driving Force Request from Transmission Control System | Drive torque limit request status from P position control to EV system | ON or OFF | OFF: Not during fail-safe control | - |
| SP1 Vehicle Speed | Vehicle speed (SP1) | Min.: 0 km/h (0 mph), Max.: 655.35 km/h (407.23 mph) | The same as actual vehicle speed | - |
| ACC Signal (Gear Shift Control Module) | ACC status | ON or OFF | ON: ACC ON (Ignition switch ON) | - |
| ACC Status (Gear Shift Control Module) | ACC judgment status used for control | ON or OFF | ON: ACC ON (Ignition switch ON) | - |
| IGCT Signal Status (Gear Shift Control Module) | IGCT signal status | ON or OFF | ON: Ignition switch ON | - |
| IG2 Signal Status (Gear Shift Control Module) | IG2 signal status | ON or OFF | ON: Ignition switch ON | - |
| IG Status (Gear Shift Control Module) | IG judgment status used for control | ON or OFF | ON: Ignition switch ON | - |
| BATT Voltage for Gear Shift Control Module | Auxiliary battery voltage | Min.: 0 V, Max.: 79.99 V | 8.0 to 15.4 V: Ignition switch ON | - |
| Sub Battery Module Voltage | Shift control supply voltage | Min.: 0 V, Max.: 79.99 V | 8.0 to 15.4 V: Ignition switch ON (During shift control supply power supply) | - |
| Gear Shift Control Module Power Supply Voltage | ECU voltage | Min.: 0 V, Max.: 79.99 V | 8.0 to 15.4 V: Ignition switch ON | - |
| Sub Battery Module Backup Status (Gear Shift Control Module) | Shift control supply backup status | Gear Shift Control Module Starting Request, Sub Battery Module Fail Safe, Backup Mode of Low SOC, Backup Mode of Normal or No Backup Mode | No Backup Mode: Ignition switch ON (READY) | - |
| Backup Request from Sub Battery Module to Gear Shift Control Module | Shift control ECU to shift control supply backup request status | Backup Stop Request, Fail-Safe, Backup Request or No Request | No Request: Ignition switch ON (READY) | - |
| Backup Relay Status | Backup light relay operation status | ON or OFF | ON: Backup light ON
OFF: Backup light OFF |
- |
| Fail Safe Status (Gear Shift Control Module) | Fail safe status | Unknown, ON or OFF | - | - |
| Shift Position Indicator Supply Voltage (Gear Shift Control Module) | Voltage value of power supplied to shift indicator and P switch connected to shift control ECU | Min.: 0 V, Max.:79.99 V | - | - |
| Shift Position Indicator Power Supply Output Status | Shift indicator power supply output status | ON or OFF | - | - |
| Shift Position (Current Position) | Shift lever actual position (judgment value) | Home, R, N, D, B/M/S or Not Available | Home: Shift lever in home position
R: Shift lever in R N: Shift lever in N D: Shift lever in D B/M/S: Shift lever in Br |
- |
| Shift Sensor Status | Shift lever position sensor malfunction status | Normal, Abnormal or Abnormal (Extreme) | Normal: Ignition switch ON | - |
| Shift Sensor Voltage (VSI1) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min.: 0 V, Max.: 4.99 V | 1.395 to 1.923 V: Shift lever in D
0.745 to 1.395 V: Shift lever in N 0.3 to 0.745 V: Shift lever in R 2.5 to 3.605 V: Shift lever in Br |
When checking with the ignition switch ON, the voltage displayed on the GTS changes according to the shift operation, but the indicator display does not reflect the actual shift operation state. |
| Shift Sensor Voltage (VSI2) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min.: 0 V, Max.: 4.99 V | 2.08 to 2.5 V: Shift lever in D
1.295 to 2.08 V: Shift lever in N 0.3 to 1.295 V: Shift lever in R 2.5 to 3.055 V: Shift lever in Br |
When checking with the ignition switch ON, the voltage displayed on the GTS changes according to the shift operation, but the indicator display does not reflect the actual shift operation state. |
| Shift Sensor Voltage (VSI3) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min.: 0 V, Max.: 4.99 V | 3.705 to 4.75 V: Shift lever in D
2.92 to 3.705 V: Shift lever in N 2.5 to 2.92 V: Shift lever in R 0.3 to 1.295 V: Shift lever in Br |
When checking with the ignition switch ON, the voltage displayed on the GTS changes according to the shift operation, but the indicator display does not reflect the actual shift operation state. |
| Shift Sensor Voltage (VSI4) (Gear Shift Control Module) | Shift lever position sensor signal input voltage (AD value) | Min.: 0 V, Max.: 4.99 V | 4.255 to 4.75 V: Shift lever in D
3.605 to 4.255 V: Shift lever in N 3.077 to 3.605 V: Shift lever in R 0.3 to 0.745 V: Shift lever in Br |
When checking with the ignition switch ON, the voltage displayed on the GTS changes according to the shift operation, but the indicator display does not reflect the actual shift operation state. |
| Shift Sensor Voltage 1 (Gear Shift Control Module) | Shift lever position sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Shift Sensor Voltage 2 (Gear Shift Control Module) | Shift lever position sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Shift Sensor Voltage 3 (Gear Shift Control Module) | Shift lever position sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Shift Sensor Voltage 4 (Gear Shift Control Module) | Shift lever position sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| M or S Shift Position Indicator Turn On Request | Shift position indicator (shift state brake (Br)) illumination status | ON or OFF | ON: Shift state brake (Br)
OFF: Shift state not brake (Br) |
- |
| D Shift Position Indicator Turn On Request | Shift position indicator (shift state drive (D)) illumination status | ON or OFF | ON: Shift state drive (D)
OFF: Shift state not drive (D) |
- |
| N Shift Position Indicator Turn On Request | Shift position indicator (shift state neutral (N)) illumination status | ON or OFF | ON: Shift state neutral (N)
OFF: Shift state not neutral (N) |
- |
| R Shift Position Indicator Turn On Request | Shift position indicator (shift state reverse (R)) illumination status | ON or OFF | ON: Shift state reverse (R)
OFF: Shift state not reverse (R) |
- |
| P Shift Position Indicator Turn On Request | Shift position indicator (shift state park (P)) illumination status | ON or OFF | ON: Shift state park (P)
OFF: Shift state not park (P) |
- |
| Parking Lock Motor Supply Current Limit Status | Limited current circuit activated or deactivated | ON or OFF | OFF: Not during fail-safe control | Turns on after turning the ignition switch to ON during the control (obtains default operation position of shift actuator). Therefore, perform the check after the control (obtains default operation position of shift actuator) is completed (after turning the ignition switch to ON and approximately 10 seconds elapse). |
| P Position Switch Terminal Voltage (Gear Shift Control Module) | P position switch terminal voltage | Min.: 0 V, Max.: 4.99 V | 1.8 to 4.99 V: Switch being pressed (for 12 V battery) | The output voltage depends on the auxiliary battery voltage. Therefore, when the auxiliary battery voltage is low, even if the function is normal it may deviate from the specified valve. |
| Stop Light Switch (Gear Shift Control Module) | Stop light switch status | ON or OFF | ON: Stop light ON
OFF: Stop light OFF |
- |
| P Position Switch Signal Voltage (Gear Shift Control Module) | P position switch signal voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Shift P Operation during Running Trigger Counter | Number of times P position switch operated while driving | Min: 0, Max: 255 | - | - |
| Shift P Operation before Vehicle Stop Trigger Counter | Number of times shift state was not changed to park (P) when P position switch operated before vehicle stopped | Min: 0, Max: 255 | - | - |
| Shift P Operation during Other than Shift P Operation Trigger Counter | Number of times P position switch operated when shift lever operated | Min: 0, Max: 255 | - | - |
| Auto Change to Shift Position P Cancel Trigger Counter | Number of times automatic park (P) function did not operate | Min: 0, Max: 255 | - | - |
| Voltage Low for Shift Control System Trigger Counter | Number of times shift control system did not operate due to low voltage | Min: 0, Max: 255 | - | - |
| Shift Operation when Auxiliary Battery Voltage Low Trigger Counter | Number of times shift state change attempted with low auxiliary battery | Min: 0, Max: 255 | - | - |
| Consecutive Shift Change between Shift P and Other than Shift P in Short Times Trigger Counter | Number of times shift state was attempted to be changed to and from park (P) within short period of time | Min: 0, Max: 255 | - | - |
| Shift Operation during Ready Indicator Blinking Trigger Counter | Number of times shift state was attempted to be changed from park (P) with READY indicator light blinking | Min: 0, Max: 255 | - | - |
| Shift R/D/B(S) Operation during Ready OFF Trigger Counter | Number of times shift state was attempted to be changed to reverse (R), drive (D) or brake (Br) with ignition switch ON | Min: 0, Max: 255 | - | - |
| Shift Operation without Depressing Brake from Shift Position P Trigger Counter | Number of times shift state was attempted to be changed from park (P) with brake pedal not depressed | Min: 0, Max: 255 | - | - |
| Shift Operation during Accelerator & Brake Depress Trigger Counter | Number of times shift state was attempted to be changed from park (P) with READY indicator light illuminated and the accelerator and the brake pedals depressed | Min: 0, Max: 255 | - | - |
| Shift B(S) Operation from Shift Position P/N Trigger Counter | Number of times shift state was attempted to be changed from park (P) or neutral (N) to brake (Br) | Min: 0, Max: 255 | - | - |
| Shift B(S) Operation from Shift Position R Trigger Counter | Number of times shift state was attempted to be changed from reverse (R) to brake (Br) | Min: 0, Max: 255 | - | - |
| Shift D Operation during Backward Movement Trigger Counter | Number of times shift state was attempted to be changed to drive (D) while backing up | Min: 0, Max: 255 | - | - |
| Shift R Operation during Forward Movement Trigger Counter | Number of times shift state was attempted to be changed to reverse (R) while driving forward | Min: 0, Max: 255 | - | - |
| Shift R/D Operation during Ready OFF Trigger Counter | Number of times shift state was changed to neutral (N) when shift lever held in R or D with ignition switch ON | Min: 0, Max: 255 | - | - |
| Shift N Operation during Running Trigger Counter | Number of times shift state was changed to neutral (N) by holding shift lever in N while driving | Min: 0, Max: 255 | - | - |
| Quick Shift Operation to Shift Position N during Running Trigger Counter | Number of times shift state was changed to neutral (N) when shift lever not held in N while driving | Min: 0, Max: 255 | - | - |
| Shift N Change by Busy Shift Trigger Counter | Number of times shift state was changed to neutral (N) by moving shift lever to R, D and/or N repeatedly within short period of time | Min: 0, Max: 255 | - | - |
| Shift N Operation on The Way Back to Home Position after Shift D/R Operation Trigger Counter | Number of times shift state was changed to neutral (N) when shift lever was returning from R or D | Min: 0, Max: 255 | - | - |
| Shift R Operation on The Way Back to Home Position after Shift D Operation Trigger Counter | Number of times shift state was changed to reverse (R) when shift lever was returning from D | Min: 0, Max: 255 | - | - |
| Shift D Operation on The Way Back to Home Position after Shift R Operation Trigger Counter | Number of times shift state was changed to drive (D) when shift lever was returning from R | Min: 0, Max: 255 | - | - |
| Shift N Operation at Short Times during Low Speed/Stopping Trigger Counter | Number of times shift state was attempted to be changed to neutral (N) without holding shift lever in N for a long enough time when driving at low speed or stopped | Min: 0, Max: 255 | - | - |
| Shift P Repeated Operation Trigger Counter during Running | Number of times shift state was changed to neutral (N) by repeatedly pressing P position switch while driving | Min: 0, Max: 255 | - | - |
| Shift P Hold Down Trigger Counter during Running | Number of times shift state was changed to neutral (N) by pressing and holding P position switch while driving | Min: 0, Max: 255 | - | - |
| Parking Lock Release by Manual Operation Trigger Counter | Number of times parking lock was released manually | Min: 0, Max: 255 | - | - |
| Shift P Operation when Auxiliary Battery Low Voltage Trigger Counter | Number of times P position switch was operated during auxiliary battery power failure | Min: 0, Max: 255 | - | - |
| Auto Change to Shift Position P when Driver Get Out Trigger Counter | Number of times automatic park (P) position switching was operated when the driver exited the vehicle | Min: 0, Max: 255 | - | - |
| Shift Position N Hold Mode ON during IG OFF/ACC ON Trigger Counter | Number of times shift position N range hold mode operated with the ignition switch off | Min: 0, Max: 255 | - | - |
| Shift Operation on Gradient during Ready OFF Trigger Counter | Number of times shift operation was performed while on a slope with the ignition switch ON | Min: 0, Max: 255 | - | - |
| Parking Lock Control Relearning Trigger Counter | Number of times parking lock control relearning was performed | Min: 0, Max: 255 | - | - |
| Shift Operation during Advanced Drive/Park Trigger Counter | Number of times shift operation was performed during advanced park | Min: 0, Max: 255 | - | - |
| Shift P Operation during Advanced Drive/Park Trigger Counter | Number of times P position switch was operated during advanced park | Min: 0, Max: 255 | - | - |
| Shift Operation during Release Shift P Restriction Request Trigger Counter | Number of times shift operation was performed during release shift P restriction | Min: 0, Max: 255 | - | - |
| Shift D/R Operation Rejection from Shift Position N without Depressing Brake Pedal Trigger Counter | Number of times switching from neutral (N) to drive (D) or reverse (R) without depressing the brake pedal was rejected | Min: 0, Max: 255 | - | - |
| Shift D/R Operation Rejection from Shift Position N during Accelerator Pedal Depress Trigger Counter | Number of times switching from neutral (N) to drive (D) or reverse (R) while depressing the accelerator pedal was rejected | Min: 0, Max: 255 | - | - |