Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
| *a | When inside of piping is pressurized |
Do not install or remove any hydrogen system components without first performing depressurization procedures.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
| *a | Manual Valve Open |
Do not perform depressurization procedures when the manual valve of the hydrogen tank assembly is open.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
When performing depressurization, do not perform procedures by hand without wearing protective glasses and gloves.
The highly pressurized hydrogen gas inside the hydrogen tank assembly could blow out, resulting in a serious accident.
| *a | After depressurization procedures, the high pressure piping union nut that is loosened first. |
After performing depressurization procedures, when first loosening the union nut of the high pressure hydrogen piping, do not loosen the union nut by hand without wearing protective glasses and gloves.
Even when depressurization procedures are performed, the pressurized hydrogen gas inside the high pressure hydrogen piping cannot be completely depressurized, so the highly pressurized hydrogen gas remaining in the high pressure hydrogen piping could blow out, resulting in a serious accident.
| *a | Heavy load exceeding the weight limits or size limits of the engine lifter |
Because the hydrogen tank assembly is extremely heavy, make sure to follow the work procedures described in the repair manual.
If work is not performed according to the procedures described in the repair manual, there is a danger that the engine lifter could drop and components could fall down.
When hoisting up the hydrogen tank assembly, do not hoist it when not properly balanced.
The hydrogen tank assembly could fall, resulting in a serious accident.
When performing the primary leak inspection, do not perform procedures without wearing protective glasses and gloves.
High pressure nitrogen gas could cause a serious accident.
When discharging pressurized hydrogen gas from the hydrogen tank assembly, do not perform the procedure in an indoor area with poor ventilation.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
While discharging pressurized hydrogen gas, the temperature inside the tank decreases and frost may form on the outside. Do not touch tanks, piping, or SST (hydrogen venting tool) when frost has formed on them.
Touching tanks, piping, or SST (hydrogen venting tool) on which frost has formed could result in burn-like injuries due to frostbite.
When opening the tank shut valve and applying pressure to SST (hydrogen venting tool), stay away from SST (flexible hose).
If SST (flexible hose) comes off, you could be struck by the loose end of SST (flexible hose), causing a serious accident.
PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
Place signs [HIGH PRESSURE GAS WORK IN PROGRESS - DO NOT TOUCH!], etc. to warn other technicians to be cautious. (An example sign is included, so make a copy and use it.)
When performing depressurization, do not open or close any parts of the hydrogen gas piping except for the following:
- Adjustment bolt of the hydrogen tank assembly manual valve
- Tank shut valve of the hydrogen tank assembly
- No. 1 hydrogen supply regulator plug
When installing or removing the hydrogen tank assembly, high pressure hydrogen piping, hydrogen inlet receptacle, hydrogen tank tube joint assembly or hydrogen supply regulator, to prevent strain such as twisting from being applied to the high pressure hydrogen piping.
Even when not removing or installing the high pressure hydrogen piping, be careful not to pull or otherwise apply strain to the high pressure hydrogen piping.
When reusable parts such as the hydrogen tank assembly valve portion, hydrogen inlet receptacle, hydrogen tube joint and hydrogen supply regulator assembly have been removed, to protect the seal portions and threaded portions from damage as well as to prevent foreign matter such as dust and metal fragments from entering through openings, cover these areas with protective tape.
Do not use packing tape, or any other tape that will leave residue on parts, as protective tape.
| *a | Protective Tape |
| *b | Seal Portion |
| *c | Threaded Portion |
Protect seal portions and threaded portions as shown in the illustration.
To protect the seal portions and threaded portions from damage or contamination by foreign matter, remove the protective tape immediately before installation.
When reassembling components that have been removed, make sure that there is no foreign matter adhering to the openings.
After installing high pressure hydrogen system components, first perform primary leak inspection with low pressure nitrogen gas, and then perform secondary leak inspection.
After installing medium pressure or low pressure hydrogen system component, perform hydrogen leak inspections (on both the medium pressure side and low pressure side).
| *a | Atmosphere Ventilation Hole Cap |
| *b | Relief Valve |
Do not insert any sharp objects into the relief valve of the hydrogen supply regulator.
Do not remove the atmosphere ventilation hole cap of the hydrogen supply regulator.
When the vehicle is parked with the ignition switch off, if the FC control ECU judges that the FC stack temperature will go below 0°C (32°F), it activates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds and drains water from the FC stack assembly. When performing inspection or repairs with the ignition switch off (not on (IG) or on (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work.