22204B
1.INSPECT MASS AIR FLOW METER SUB-ASSEMBLY
| *a | Temperature Sensor (Thermistor) |
Perform a visual check for temperature sensor (thermistor) of the mass air flow meter sub-assembly shown in the illustration.
There is no foreign matter.
If the result is not as specified, replace the mass air flow meter sub-assembly.
| *a | Component without harness connected
(Mass Air Flow Meter Sub-assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A49)Location & Routingewd_type=routing;type=c;code=A49 |
||
| A49-4 (THA) - A49-2 (E2G) | -20°C (-4°F) | 13.6 to 18.4 kΩ |
| A49-4 (THA) - A49-2 (E2G) | 20°C (68°F) | 2.21 to 2.69 kΩ |
| A49-4 (THA) - A49-2 (E2G) | 60°C (140°F) | 0.49 to 0.67 kΩ |
If the result is not as specified, replace the mass air flow meter sub-assembly.