G4133
1.INSPECT HYDROGEN SECONDARY PRESSURE SENSOR
Check the power source voltage.
Disconnect the hydrogen secondary pressure sensor connector.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B11)Location & Routingewd_type=routing;type=c;code=B11 Click Connector(B11)Engine Compartment>No. 2 Stack Wire>Hydrogen Secondary Pressure Sensorewd_type=component;type=c;code=B11;pinno=3,2,1 |
||
| B11-3(VHPL) - B11-2(GHPL) | IG ON | 4.75 to 5.25 V |
| B11-1(HPL) - B11-2(GHPL) | IG ON | 3.0 to 5.25 V |
If the measurement result is approximately 0 V, there may be an open on the VHPL circuit or GHPL circuit.
Check the low-range hydrogen pressure.
Connect the GTS to the DLC3.
Turn the ignition switch on (IG).
Enter the following menus: Powertrain / FC / Data List / Low-Range Hydrogen Pressure
| Tester Display |
|---|
| Low-Range Hydrogen Pressure |
Read the hydrogen secondary pressure sensor value.
"Atmospheric pressure plus 10 kPa" to "280 kPa(abs)"
Standard atmospheric pressure is 101 kPa (abs) [758 mmHg (abs)].
For every 100 m (328 ft.) increase in altitude, pressure drops by 1 kPa (7.5 mmHg).
Make sure that the vehicle is stopped with the ignition switch ON (READY) ("FC Mode" on the Data List (EV) indicates "FC Working" and "FC Intermittent Operation" indicates "OFF").