84973
1.INSPECT FC WATER RELEASE SWITCH
Check the resistance.
| *a | Component without harness connected
(FC Water Release Switch) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D107)Location & Routingewd_type=routing;type=c;code=D107 Click Connector(D107)Instrument Panel>Instrument Panel Wire>FC Water Release Switchewd_type=component;type=c;code=D107;pinno=4,5 |
||
| D107-4 (E) - D107-5 (SW) | Switch on | Below 1 Ω |
| D107-4 (E) - D107-5 (SW) | Switch off | 10 kΩ or higher |
If the result is not as specified, replace the FC water release switch.
Check illumination.
Connect the negative auxiliary battery cable and positive auxiliary battery cable to the indicated terminals of the connector and check that the LED illuminates.
| Tester Connection | Specified Condition |
|---|---|
|
Click Location & Routing(D107)Location & Routingewd_type=routing;type=c;code=D107 Click Connector(D107)Instrument Panel>Instrument Panel Wire>FC Water Release Switchewd_type=component;type=c;code=D107;pinno=6,3 |
|
| Auxiliary battery positive (+) → D107-6 (ILL+)
Auxiliary battery negative (-) → D107-3 (ILL-) |
LED illuminates |
If the result is not as specified, replace the FC water release switch.