Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2020.11–2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM D

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  FREEZE FRAME DATA  


FREEZE FRAME DATA


HINT:

The EV control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / EV / Trouble Codes.

Powertrain > EV > Trouble Codes
50001 397

e.

Select a DTC in order to display its freeze frame data.


f.

Check the freeze frame information recorded with the DTC.

Powertrain > EV
Tester Display Measurement Item Range
Vehicle Speed Vehicle speed Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
Maximum Vehicle Speed Maximum vehicle speed Min.: 0 km/h (0 mph), Max.: 254 km/h (157 mph)
Starter Switch Signal Starter ON / OFF signal OFF or ON
Engine Start Request (Hybrid/EV Battery Charging) Engine idling request to charge EV supply battery assembly OFF or ON
Accelerator Position Accelerator pedal depressed angle Min.: 0.0%, Max.: 100.0%
Accelerator Pedal Status Accelerator Pedal Status OFF or ON
Accelerator Position Sensor No.1 Voltage % Accelerator pedal position sensor No. 1 Min.: 0.00%, Max.: 100.00%
Accelerator Position Sensor No.2 Voltage % Accelerator pedal position sensor No. 2 Min.: 0.00%, Max.: 100.00%
Master Cylinder Control Torque Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque)
Min.: -4096.00 Nm, Max.: 4095.87 Nm
Brake Cancel Switch Brake pedal status OFF or ON
Shift Position Current shift state P / R / N / D / B
Shift Position (Meter) Shift position of meter display Not Displayed / P / R / N / D / B
Shift Switch Status (N,P Position) Shift position status (N or P position) ON or OFF
Transaxle Oil Temperature FCV with motor transaxle oil temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
Transaxle Oil Temperature Sensor Voltage Transaxle fluid temperature sensor voltage Min: 0.00 V, Max: 4.99 V
FR Wheel Speed Front wheel speed RH Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
FL Wheel Speed Front wheel speed LH Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
RR Wheel Speed Rear wheel speed RH Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
RL Wheel Speed Rear wheel speed LH Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph)
Steering Angle Signal Steering angle signal Min.: -3276.8 deg, Max.: 3276.7 deg
Yaw Rate Value Yaw rate value Min.: -128.0 deg/s, Max.: 127.9 deg/s
Atmospheric Pressure Sensor Voltage Atmospheric pressure sensor voltage Min.: 0.00 V, Max.: 4.99 V
Atmospheric Pressure Atmospheric pressure Min.: 0 kPa(abs) (0 psi), Max.: 655.35 kPa(abs) (95 psi)
Atmospheric Pressure (Filtered Value) Atmospheric pressure (filtered value) Min.: 0 kPa(abs) (0 psi), Max.: 655.35 kPa(abs) (95 psi)
Atmospheric Pressure (MG) Atmospheric pressure (MG) Min.: 0 kPa(abs) (0 psi), Max.: 655.35 kPa(abs) (95 psi)
Ambient Temperature Ambient air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
Estimate Gradient of Road Surface (Right and Left) Estimate gradient of road surface (right and left) Min.: -25.6 deg, Max.: 25.4 deg
Ready Lighting Request (Normal Start) Ready lighting request (normal start) OFF or ON
Freeze Start Rejection Freeze start rejection OFF or ON
BATT Voltage Auxiliary battery voltage
(BATT terminal voltage)
Min.: 0.00 V, Max.: 79.99 V
Smoothed Value of BATT Voltage Smoothed value of auxiliary battery voltage Min.: 0.00 V, Max.: 65.535 V
Total Voltage Total voltage Min.: 0.00 V, Max.: 65.535 V
Internal Voltage Internal voltage Min.: 0.00 V, Max.: 65.535 V
Input Power Input power Min.: 0.00 kW, Max.: 12.75 kW
Internal Power Supply Voltage (VHMR) Internal power supply voltage (VHMR) Min.: 0.00 V, Max.: 79.99 V
Distance from DTC Cleared Drive distance after clearing DTCs Min.: 0, Max.: 65535
Total Distance Traveled Drive total distance Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile)
Total Distance Traveled - Unit Drive total distance unit km or mile
MIL ON Run Distance Drive distance from MIL on Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
IG Switch (Twice Read) IG switch (twice read) OFF or ON
IGB Signal Status IGB signal status OFF or ON
IG2 Signal Status IG2 signal status OFF or ON
IG2 Controlling Signal Status IG2 controlling signal status OFF or ON
IGBD Status IGBD status OFF or ON
IGBD Signal Status IGBD signal status OFF or ON
IG ON Status IG ON status OFF or ON
Ready Signal Ready signal status OFF or ON
HV/EV Activate Condition Hybrid control system power source mode status Normal / Remote Air Control System / Remote
DSS Control Status Control status of DSS (Driving Support System) Not Control / Available / Unavailable / Disable
Generate Torque (Request from DSS) Generated drive torque requested from DSS (Driving Support System) Min.: -4096.00 Nm, Max.: 4095.87 Nm
Target Propeller Shaft Torque (DSS Last Time Value) Target propeller shaft torque (DSS last time value) Min.: -4096.00 Nm, Max.: 4095.87 Nm
Primary Driving Force Adjustment Result Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation Accelerator or DSS
SMRG Status Operating state of SMRG
(primary circuit monitor)
OFF or ON
SMRG Control Status Commanded state of SMRG OFF or ON
SMRB Status Operating state of SMRB
(primary circuit monitor)
OFF or ON
SMRB Control Status Commanded state of SMRB OFF or ON
SMRP Status Operating state of SMRP
(primary circuit monitor)
OFF or ON
SMRP Control Status Commanded state of SMRP OFF or ON
SMRP Current-Carrying SMRP current-carrying Able or Unable
WIN Control Limit Power WIN control limit power Min.: 327.68 kW, Max.: 327.67 kW
WOUT Control Limit Power WOUT control limit power Min.: 327.68 kW, Max.: 327.67 kW
GL1 GX Sensor Signal GL1 GX sensor signal Min.: 13.107 m/s2, Max.: 13.106 m/s2
GL2 GY Sensor Signal GL2 GY sensor signal Min.: 13.107 m/s2, Max.: 13.106 m/s2
A/C Consumption Power A/C consumption power Min.: 0.00 kW, Max.: 12.75 kW
Mode Status Mode status Waiting / Driving / Battery Charging / Auxiliary Battery Charging / Battery Diagnosis / Battery Charging (Battery Diagnosis) / Parking Purge / Power Feeding / Remote A/C / SMR Connect / Emergency Power Feeding / Stop
Drive Mode Switch- DRIVE MODE switch (NO. 1 pattern select switch assembly) status OFF or ON
Drive Mode Switch+ DRIVE MODE switch (NO. 1 pattern select switch assembly) status OFF or ON
Drive Mode Status Drive mode status Initial Value / Preparing / Driving / Finish
Snow Mode Status Snow mode status OFF or ON
Snow Mode Switch SNOW mode switch (pattern select switch assembly) condition ON or OFF
Hybrid/EV Control Current Hybrid control current Min.: -3276.8 A, Max.: 3276.7 A
Hybrid/EV Control Total Voltage Hybrid control total voltage Min.: 0.00 V, Max.: 65.535 V
LIN4 Communication Control Permission LIN4 communication control permission NG or OK
Inter Lock Switch Interlock switch condition OFF or ON
Stop Light Switch Stop light switch assembly condition OFF or ON
Airbag Status (Collision) Airbag ECU assembly collision detection OFF or ON
Airbag Status (Collision) (CAN) Airbag ECU assembly collision detection
(CAN)
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side
Airbag Status (Normal) Control state of airbag ECU assembly OFF or ON
TC Terminal TC terminal state OFF or ON
Motor Revolution Motor (MG2) speed (detected by resolver sensor) Min.: -32768 rpm, Max.: 32767 rpm
Target Motor Torque Motor (MG2) torque request value Min.: -4096.00 Nm, Max.: 4095.87 Nm
Request Motor Regenerative Brake Torque Requested motor (MG2) regenerative braking torque Min.: -4096.00 Nm, Max.: 4095.87 Nm
Motor Regenerate Brake Execution Torque Motor (MG2) regenerative braking execution torque Min.: -4096.00 Nm, Max.: 4095.87 Nm
Motor Temperature Motor (MG2) temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
Motor Temperature Sensor Voltage Motor (MG2) temperature sensor voltage Min.: 0 V, Max.: 4.99 V
Motor Temperature just after IG ON Motor (MG2) temperature soon after ignition switch ON Min.: -40°C (-40°F), Max.: 215°C (419°F)
Motor Maximum Temperature Maximum motor (MG2) temperature after ignition switch turned to ON in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F)
Motor Inverter Temperature Motor inverter temperature Min.: 15°C (-59°F), Max.: 150°C (302°F)
Motor Inverter Temperature just after IG ON Motor inverter temperature soon after ignition switch ON Min.: 15°C (-59°F), Max.: 150°C (302°F)
Motor Inverter Maximum Temperature Maximum motor inverter temperature after ignition switch turned to ON in current trip Min.: 15°C (-59°F), Max.: 150°C (302°F)
Boosting Converter Temperature (Upper) Boost converter temperature (upper) Min.: -40°C (-40°F), Max.: 215°C (419°F)
Boosting Converter Temperature (Lower) Boost converter temperature (lower) Min.: -40°C (-40°F), Max.: 215°C (419°F)
Boosting Converter Temperature just after IG ON Boost converter temperature soon after ignition switch ON Min.: -40°C (-40°F), Max.: 215°C (419°F)
Boosting Converter Maximum Temperature Maximum converter temperature after ignition switch turned to ON in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F)
Boosting Converter Operation Request Boosting converter operation request Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering
Motor Carrier Frequency Motor (MG2) carrier frequency 0 to 255
Motor Control Mode Motor (MG2) control mode Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
Boosting Converter Carrier Frequency Boost converter signal carrier frequency HI or LO
Boosting Converter Gate Shutdown Request Boosting converter gate shutdown request OFF or ON
Boosting Converter Shutdown Status Boosting converter shutdown status Awake or Shutdown
Boosting Converter Overcurrent Boosting converter overcurrent OFF or ON
Boosting Converter Input Overvoltage Boosting converter input overvoltage OFF or ON
Motor Operation Status Motor operation status Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive
Motor Torque Estimate Value Motor torque estimate value Min.: -4096.00 Nm, Max.: 4095.87 Nm
Motor Gate Shutdown Request Motor gate shutdown request OFF or ON
Motor Inverter Shutdown Status Motor inverter shutdown status OFF or ON
Motor Inverter Overcurrent Motor inverter overcurrent OFF or ON
VL-Voltage before Boosting High voltage before it is boosted -
VH-Voltage after Boosting High voltage after it is boosted -
Boost Ratio Boost converter boost ratio Min.: 0.0%, Max.: 100.0%
V Phase Motor Current V phase motor current Min.: -3276.8 A, Max.: 3276.7 A
W Phase Motor Current W phase motor current Min.: -3276.8 A, Max.: 3276.7 A
DC/DC Converter Stop Request DC/DC converter stop request OFF or ON
DC/DC Converter Terminal Voltage (Abnormal Detection Signal) DC/DC converter terminal voltage (abnormal detection signal) Min.: 0.00 V, Max.: 4.98 V
DC/DC Converter Output Voltage Change Signal DC/DC converter output voltage change signal Min.: 0.00 V, Max.: 4.98 V
DC/DC Converter Output Voltage Change Signal Duty DC/DC converter output voltage change signal duty Min.: 0.0%, Max.: 127.5%
Inverter Coolant Water Temperature Inverter coolant temperature Min.: -40°C (-40°F), Max.: 110°C (230°F)
Inverter Water Pump Duty Ratio Water with motor pump motor driver request duty Min.: 0.0%, Max.: 100.0%
Inverter Water Pump Revolution Water with motor pump assembly speed Min.: 0 rpm, Max.: 15000 rpm
Inverter Emergency Shutdown (Main CPU) Inverter emergency shutdown (main CPU) OFF or ON
Inverter Emergency Shutdown (Sub CPU) Inverter emergency shutdown (sub CPU) ON or OFF
Inverter Input Overvoltage Inverter input overvoltage OFF or ON
Inverter Water Pump Drive Request Water with motor pump drive request Stop / Super Extra Low / Extra Low / Low / Middle / High
AC Inverter Start AC Inverter Start Able or Unable
Target MG Cooling Oil Pump Motor Duty Oil with motor pump request duty Min.: 0.0%, Max.: 100.0%
MG Cooling Oil Pump Motor Speed Oil with motor pump motor speed Min.: 0 rpm, Max.: 65535 rpm
MG Cooling Oil Pump Motor Power Relay Request OIL PMP MTR relay operation request OFF or ON
MG Shutdown Signal Monitor Voltage MG shutdown signal monitor voltage 0.0 to 4.98 V
Hybrid/EV Battery SOC EV supply battery state of charge
Primary calculated from charging and discharging amperage
Min.: 0.00%, Max.: 100.00%
Hybrid/EV Battery SOC just after IG ON EV supply battery state of charge soon after ignition switch ON Min.: 0.0%, Max.: 127.5%
Hybrid/EV Battery Maximum SOC Maximum SOC after ignition switch turned to ON in current trip Min.: 0.0%, Max.: 127.5%
Hybrid/EV Battery Minimum SOC Minimum SOC after ignition switch turned to ON in current trip Min.: 0.0%, Max.: 127.5%
Hybrid/EV Battery Voltage EV supply battery voltage Min.: 0.00 V, Max.: 510.00 V
Hybrid/EV Battery Current EV supply battery current Min.: -327.68 A, Max.: 327.67 A
Hybrid/EV Battery Current for Driving Control EV supply battery current for driving control Min.: -327.68 A, Max.: 327.67 A
Hybrid/EV Battery Control Mode EV supply battery current mode Driving Control Mode / Current Sensor Offset Calibration Mode / Hybrid/EV Battery External Charging Control Mode / ECU Shutdown Mode
Hybrid/EV Battery Cooling Fan Low Speed Request Battery cooling blower assembly Lo speed requested OFF or ON
Short Wave Highest Value Level Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3
Insulation Resistance Division Check Completion using MG Inv Insulation resistance division check completion using MG inv Not Complete or Complete
Insulation Resistance Division Check Completion using A/C Inv Insulation resistance division check completion using A/C inv Not Complete or Complete
Insulation Resistance Division Check Completion using SMR Insulation resistance division check completion using SMR Not Complete or Complete
Short Wave Highest Value Availability just after MG Inv On/Off Short wave highest value availability just after MG inv on/off Yes or No
Short Wave Highest Value Availability just after A/C Inv On/Off Short wave highest value availability just after A/C inv on/off Yes or No
Short Wave Highest Value Availability just after SMR On/Off Short wave highest value availability just after SMR on/off Yes or No
Hybrid/EV System Insulation Status Hybrid system insulation status Not Judged / Normal / Abnormal / Abnormal (Large)
FC Air Compressor Area Insulation Resistance Division Check Completion FC air compressor area insulation resistance division check completion Not Complete or Complete
FC Coolant Pump Area Insulation Resistance Division Check Completion FC cooling water pump area insulation resistance division check completion Not Complete or Complete
Hydrogen Pump Area Insulation Resistance Division Check Completion Hydrogen recirculation pump area insulation resistance division check completion Not Complete or Complete
FC Area Insulation Resistance Division Check Completion FC area insulation resistance division check completion Not Complete or Complete
Motor Area Insulation Resistance Division Check Completion Motor area insulation resistance division check completion Not Complete or Complete
A/C Area Insulation Resistance Division Check Completion A/C area insulation resistance division check completion Not Complete or Complete
Hybrid/EV Battery Area Insulation Resistance Division Check Completion EV supply battery area insulation resistance division check completion Not Complete or Complete
Insulation Resistance Deterioration Elapsed Time Insulation resistance deterioration elapsed time Min.: 0 min, Max.: 65535 min
Short Wave Highest Value Short wave highest value Min.: 0.00 V, Max.: 4.98 V
Immobiliser Communication Immobiliser communication line status OFF or ON
Permit Start by Immobiliser Status of starting permission by immobiliser (immobiliser to EV control ECU) No Judgment / OK / NG
Auxiliary Battery Voltage Auxiliary battery voltage (+B3, +B4 terminals voltage) Min.: 0.00 V, Max.: 16.00 V
Auxiliary Voltage Auxiliary voltage Min.: 0.00 V, Max.: 20.00 V
Auxiliary Battery Current Auxiliary battery current Min.: -125.00 A, Max.: 124.99 A
Smoothed Value of Auxiliary Battery Temperature Smoothed value of auxiliary battery temperature Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F)
Auxiliary Battery Status of Full Charge Auxiliary battery status when full charge Min.: 0.00 Ah, Max.: 127.5 Ah
Auxiliary Battery Charging Rate Accuracy Auxiliary battery charging rate accuracy Low / Middle / High / Disable
Auxiliary Battery Power Supply Voltage Low Auxiliary battery power supply voltage low OFF or ON
FC Work Mode Mode of the FC stack operation Stop / Finishing / Startup / Working
FC System Status FC system status Stop / Finishing / Startup / Working
FC Power Generation Status Mode of the FC stack power generation Normal / Intermittent / Quick Warmup
FC Converter Status FC boost converter status Normal or Abnormal
FC Converter Shutdown Request Shut down request to the FC boost control ECU OFF or ON
FC Converter Shutdown Status FC boost converter shutdown status OFF or ON
FC Converter Shutdown Signal FC boost converter shutdown signal OFF or ON
FC Air Compressor Gate Shutdown Request FC air compressor inverter shutdown request OFF or ON
FC Air Compressor Shutdown Status FC air compressor inverter shutdown status OFF or ON
FC Air Compressor Consumption Power Measure power consumption of the FC air compressor with motor assembly Min.: 0 W, Max.: 65535 W
FC Air Compressor Temperature just after IG ON FC air compressor motor temperature soon after ignition switch ON Min.: -40°C (-40°F), Max.: 215°C (419°F)
FC Air Compressor Maximum Temperature Maximum FC air compressor motor temperature after ignition switch turned to ON in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F)
FC Air Compressor Motor Operation Status FC air compressor motor operation status Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive
FC Air Compressor Motor Control Mode FC air compressor motor control mode Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode
V Phase FC Air Compressor Motor Current V phase FC air compressor motor current Min.: -3276.8 A, Max.: 3276.7 A
W Phase FC Air Compressor Motor Current W phase FC air compressor motor current Min.: -3276.8 A, Max.: 3276.7 A
FC Air Compressor Motor Carrier Frequency FC air compressor motor carrier frequency 0 to 255
FC Air Compressor Motor Temperature FC air compressor motor temperature Min.: -40°C (-40°F), Max.: 215°C (419°F)
FC Air Compressor Motor Temperature (Filtered Value) FC air compressor motor temperature filtered value Min.: -40°C (-40°F), Max.: 215°C (419°F)
FC Air Compressor Motor Torque Estimate Value FC air compressor motor torque estimate value Min.: -4096 Nm, Max.: 4095.87 Nm
FC Air Compressor Inverter Shutdown Status FC air compressor inverter shutdown OFF or ON
FC Air Compressor Inverter Stop FC air compressor inverter stopped OFF or ON
FC Air Compressor Inverter Maximum Temperature Maximum FC air compressor inverter temperature after ignition switch turned to ON in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F)
FC Air Compressor Inverter Overcurrent Overcurrent detection into FC air compressor inverter OFF or OM
FC Air Compressor Inverter Temperature FC air compressor inverter temperature Min.: -40°C (-40°F), Max.: 215.9°C (421°F)
FC Air Compressor Inverter Temperature (Filtered Value) FC air compressor inverter temperature filtered value Min.: -40°C (-40°F), Max.: 215.9°C (421°F)
FC Air Compressor Inverter Temperature just after IG ON FC air compressor inverter temperature soon after ignition switch ON Min.: -40°C (-40°F), Max.: 215.9°C (421°F)
FCDC Input Voltage FC boost converter (FC converter power module transistor) input voltage sensor value Min.: 0 V, Max.: 6553.5 V
FCDC Output Voltage FC boost converter (FC converter power module transistor) output voltage sensor value Min.: 0 V, Max.: 6553.5 V
Power Feeding Electrical Using Status Usage state of power supplied from external power source charging Charge Sustaining Mode / Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF