DATA LIST
Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / EV / Data List.
Check the results by referring to the following table.
When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the update time for each item will be longer, resulting in delayed or incorrect data.
Using a custom list makes it possible to easily select smaller groups of related Data List items.
The following custom lists are available:
Primary
Hybrid/EV Battery
Hybrid/EV Battery Temperature
Inverter
Hybrid/EV Coolant Temperature
Shift
Insulation Abnormal
SMR
Ready ON
DC/DC Converter
Auxiliary Battery
Resolver Learning
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | Vehicle stopped:
0 km/h (0 mph) While driving at a constant speed: No significant fluctuation |
- |
| Maximum Vehicle Speed | MAximum vehicle speed | Min.: 0 km/h (0 mph), Max.: 254 km/h (157 mph) | - | - |
| Starter Switch Signal | Starter ON / OFF signal | OFF or ON | Starter ON:
ON |
- |
| Engine Start Request (Hybrid/EV Battery Charging) | Engine idling request to charge EV supply battery | OFF or ON | Requesting EV supply battery charging:
ON |
·
Battery voltage sensor (for upper side) ·
Battery voltage sensor (for lower side) ·
Battery ECU assembly ·
EV supply battery |
| Current Fuel Type | Current fuel type | - | - | - |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 100.0% | Accelerator pedal fully depressed:
100% Accelerator pedal released: 0% |
Accelerator pedal (with sensor) rod assembly |
| Accelerator Pedal Status | Accelerator Pedal Status | OFF or ON | Accelerator pedal depressed:
ON Accelerator pedal released: OFF |
Accelerator pedal (with sensor) rod assembly |
| Accelerator Position Sensor No.1 Voltage % | Accelerator pedal position sensor No. 1 | Min.: 0.00%, Max.: 100.00% | Accelerator pedal depressed:
Changes with accelerator pedal position |
Sensor voltage is multiplied by 20 and displayed as a percentage
Accelerator pedal (with sensor) rod assembly |
| Accelerator Position Sensor No.2 Voltage % | Accelerator pedal position sensor No. 2 | Min.: 0.00%, Max.: 100.00% | Accelerator pedal depressed:
Changes with accelerator pedal position |
Sensor voltage is multiplied by 20 and displayed as a percentage
Accelerator pedal (with sensor) rod assembly |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque) |
- | Brake pedal depressed:
Changes with the brake pedal pressure |
Master cylinder brake fluid pressure control torque = hydraulic brake control torque + regenerative brake torque
Master cylinder pressure sensor |
| Brake Cancel Switch | Brake cancel switch state | OFF or ON | Brake pedal depressed:
OFF Brake pedal released: ON |
- |
| Shift Position | Current shift state | P / R / N / D / B | Matches currently selected shift state:
P, R, N, D or Br |
Shift state
When the value of Shift Position (Meter) is "Not Displayed" and the value of Shift Position is "N", the actual shift position cannot be determined and the parking lock may be engaged. |
| Shift Position (Meter) | Shift position of meter display | Not Displayed / P / R / N / D / B | Matches currently selected shift state:
P, R, N, D or Br |
Shift state |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | OFF or ON | Shift state park (P) or neutral (N):
ON |
Shift state |
| Transaxle Oil Temperature | FCV with motor transaxle oil temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Transaxle Oil Temperature Sensor Voltage | Transaxle fluid temperature sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| FR Wheel Speed | Front wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped:
0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| FL Wheel Speed | Front wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped:
0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| RR Wheel Speed | Rear wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped:
0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| RL Wheel Speed | Rear wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) | Vehicle stopped:
0 km/h (0 mph) Vehicle being driven at a constant speed: No large fluctuations in displayed speed |
- |
| Steering Angle Signal | Steering angle signal | Min.: -3276.68 deg, Max.: 3276.7 deg | - | - |
| Yaw Rate Value | Yaw rate value | Min.: -128 deg/s, Max.: 127.9 deg/s | - | - |
| Atmospheric Pressure Sensor Voltage | Output voltage of the barometric pressure sensor | Min.: 0 V, Max.: 4.99 V | - | If the "Atmospheric Pressure Sensor Voltage" is more than 4.70 V or less than 0.30 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Atmospheric Pressure | Atmospheric pressure | Min.: 0 kPa(abs), Max.: 655.35 kPa(abs) | Constant: Atmosphere pressure | ·
Standard atmospheric pressure is approximately 101 kPa (15 psi). ·
For every 100 m (328 ft.) increase in altitude, atmospheric pressure drops by approximately 1 kPa (0.1 psi). This varies by weather. ·
Barometric pressure sensor value is built into the EV control ECU. |
| Atmospheric Pressure (Filtered Value) | Atmospheric pressure filtered value | Min.: 0 kPa(abs), Max.: 655.35 kPa(abs) | - | - |
| Atmospheric Pressure (MG) | Atmospheric pressure (MG) | Min.: 0 kPa(abs), Max.: 655.35 kPa(abs) | Constant: Atmosphere pressure | Barometric pressure sensor value is built into the motor generator control ECU (MG ECU). |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Ignition switch ON:
Same as ambient air temperature |
Ambient temperature sensor |
| BATT Voltage | Auxiliary battery voltage
(BATT terminal voltage) |
Min.: 0.00 V, Max.: 79.99 V | 11.00 to 15.00 V | BATT terminal |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage | Min.: 0.00 V, Max.: 65.535 V | 11.000 to 15.000 V | EV control ECU |
| Total Voltage | Total voltage | Min.: 0.00 V, Max.: 65.535 V | - | - |
| Internal Voltage | Internal voltage | Min.: 0.00 V, Max.: 65.535 V | - | - |
| Input Power | Input power | Min.: 0.00 V, Max.: 12.75 kW | - | - |
| Internal Power Supply Voltage (VHMR) | Internal power supply voltage (VHMR) | Min.: 0.00 V, Max.: 79.99 V | - | - |
| Distance from DTC Cleared | Drive distance after clearing DTCs | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| MIL | MIL status | OFF or ON | - | - |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - | - |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile | - | - |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Number of Emission DTC | Emissions-related DTCs | Min.: 0, Max.: 127 | - | - |
| OBD Requirements | OBD requirements | OFF or ON | - | - |
| IG Switch (Twice Read) | IG switch (twice read) | OFF or ON | - | - |
| IGB Signal Status | IGB signal status | OFF or ON | - | - |
| IG2 Signal Status | IG2 signal status | OFF or ON | - | - |
| IG2 Controlling Signal Status | IG2 controlling signal status | OFF or ON | - | - |
| IGBD Status | IGBD status | OFF or ON | - | - |
| IGBD Signal Status | IGBD signal status | OFF or ON | - | - |
| IG ON Status | IG ON status | OFF or ON | - | - |
| Ready Signal | Ready signal status | OFF or ON | Ignition switch ON (READY):
ON |
- |
| HV/EV Activate Condition | Hybrid control system power source mode status | Normal / Remote Air Control System / Remote | Hybrid control system started using ignition switch:
Normal Hybrid control system started using remote air control system function: Remote Air Control System Hybrid control system started using remote starter: Remote |
- |
| DSS Control Status | Control status of DSS (Driving Support System) | Not Control / Available / Unavailable / Disable | - | - |
| Generate Torque (Request from DSS) | Generated drive torque requested from DSS (Driving Support System) | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - | - |
| Target Propeller Shaft Torque (DSS Last Time Value) | Target propeller shaft torque (DSS last time value) | Min.: -4096.00 Nm, Max.: 4095.87 Nm | - | - |
| Primary Driving Force Adjustment Result | Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation | Accelerator / DSS | Drive force requested by accelerator pedal operation selected:
Accelerator Drive force requested by DSS selected: DSS |
- |
| SMRG Status | Operating state of SMRG
(primary circuit monitor) |
OFF or ON | Ignition switch ON (READY):
ON |
·
NO. 1 EV battery junction block assembly ·
Wire harness |
| SMRG Control Status | Commanded state of SMRG | OFF or ON | Ignition switch ON (READY):
ON |
·
NO. 1 EV battery junction block assembly ·
Wire harness |
| SMRB Status | Operating state of SMRB
(primary circuit monitor) |
OFF or ON | Ignition switch ON (READY):
ON |
·
NO. 1 EV battery junction block assembly ·
Wire harness |
| SMRB Control Status | Commanded state of SMRB | OFF or ON | Ignition switch ON (READY):
ON |
·
NO. 1 EV battery junction block assembly ·
Wire harness |
| SMRP Status | Operating state of SMRP
(primary circuit monitor) |
OFF or ON | Immediately after the ignition switch ON (ST-ON) state occurred:
ON After the above timing: OFF |
Cannot be confirmed using the GTS. Use an oscilloscope.
·
NO. 1 EV battery junction block assembly ·
Wire harness |
| SMRP Control Status | Commanded state of SMRP | OFF or ON | Immediately after the ignition switch ON (ST-ON) state occurred:
ON After the above timing: OFF |
Cannot be confirmed using the GTS. Use an oscilloscope.
·
NO. 1 EV battery junction block assembly ·
Wire harness |
| SMRP Current-Carrying | SMRP current-carrying | Able or Unable | - | - |
| WIN Control Limit Power | WIN control limit power | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| WOUT Control Limit Power | WOUT control limit power | Min.: -327.68 kW, Max.: 327.67 kW | - | - |
| GL1 GX Sensor Signal | GL1 GX sensor signal | Min.: -13.107 m/s2, Max.: 13.106 m/s2 | - | - |
| GL2 GY Sensor Signal | GL2 GY sensor signal | Min.: -13.107 m/s2, Max.: 13.106 m/s2 | - | - |
| A/C Consumption Power | A/C consumption power | Min.: 0.00 kW, Max.: 12.75 kW | While the air conditioning system is operating:
0 to 5.00 kW |
·
Air conditioning system ·
Battery ECU assembly |
| Mode Status | Mode status | Waiting / Driving / Battery Charging / Auxiliary Battery Charging / Battery Diagnosis / Battery Charging (Battery Diagnosis) / Parking Purge / Power Feeding / Remote A/C / SMR Connect / Emergency Power Feeding / Stop | - | - |
| Drive Mode Switch- | DRIVE MODE switch (NO. 1 pattern select switch assembly) status | OFF or ON | ·
DRIVE MODE switch (NO. 1 pattern select switch assembly) not operated: OFF ·
Operated DRIVE MODE switch (NO. 1 pattern select switch assembly) backward: ON |
Drive Mode Select Switch Circuit |
| Drive Mode Switch+ | DRIVE MODE switch (NO. 1 pattern select switch assembly) status | OFF or ON | ·
DRIVE MODE switch (NO. 1 pattern select switch assembly) not operated: OFF ·
Operated DRIVE MODE switch (NO. 1 pattern select switch assembly) forward: ON |
Drive Mode Select Switch Circuit |
| Drive Mode Status | Drive mode status | Initial Value / Preparing / Driving / Finish | - | - |
| Snow Mode Status | Snow mode status | OFF or ON | SNOW mode:
ON Not SNOW mode: OFF |
- |
| Snow Mode Switch | SNOW mode switch (pattern select switch assembly) condition | OFF or ON | SNOW mode switch (pattern select switch assembly) operated:
ON SNOW mode switch (pattern select switch assembly) not operated: OFF |
Pattern Select Switch Snow Mode Circuit |
| Hybrid/EV Control Current | Hybrid control current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Hybrid/EV Control Total Voltage | Hybrid control total voltage | Min.: 0.00 V, Max.: 65.535 V | - | - |
| LIN4 Communication Control Permission | LIN4 communication control permission | NG or OK | - | - |
| Inter Lock Switch | Interlock switch condition | OFF or ON | Ignition switch ON, service plug grip, inverter terminal cover, connector cover assembly or front compartment main wire not installed:
ON |
ILK terminal |
| Stop Light Switch | Stop light switch assembly condition | OFF or ON | Brake pedal depressed:
ON |
- |
| Airbag Status (Collision) | Airbag ECU assembly collision detection | OFF or ON | - | - |
| Airbag Status (Collision) (CAN) | Airbag ECU assembly collision detection
(CAN) |
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side | - | - |
| Airbag Status (Normal) | Control state of airbag ECU assembly | OFF or ON | - | - |
| TC Terminal | TC terminal state | OFF or ON | TC terminal connected:
ON |
- |
| Body Control with Torque Demand | Body Control with Torque Demand status | ON or OFF | Under the Body Control with Torque Demand:
ON |
- |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm | While driving:
Varies depending on vehicle speed |
Motor (MG2) speed changes in proportion to vehicle speed. Motor (MG2) speed is not influenced by accelerator pedal opening angle, FC air compressor speed.
·
FCV with motor transaxle assembly ·
Inverter with converter assembly |
| Target Motor Torque | Motor (MG2) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm | While driving:
Varies depending on vehicle operating conditions |
·
EV control ECU ·
FCV with motor transaxle assembly ·
Inverter with converter assembly |
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm | While braking:
Varies depending on vehicle operation conditions |
When regenerative braking is being performed, current flows from the motor to charge the EV supply battery and braking torque is generated.
Electronically controlled brake system |
| Motor Regenerate Brake Execution Torque | Motor (MG2) regenerative braking execution torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm | While braking:
Varies depending on vehicle operation conditions |
·
EV control ECU ·
FCV with motor transaxle assembly ·
Inverter with converter assembly |
| Motor Temperature | Motor (MG2) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
25°C (77°F) While driving: Varies depending on vehicle operating conditions |
- |
| Motor Temperature Sensor Voltage | Motor (MG2) temperature sensor voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Motor Temperature just after IG ON | Motor (MG2) temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Motor Maximum Temperature | Maximum motor (MG2) temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Motor Inverter Temperature | Motor inverter temperature | Min.: 15°C (59°F), Max.: 150°C (302°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Motor Inverter Temperature just after IG ON | Motor inverter temperature soon after ignition switch ON | Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| Motor Inverter Maximum Temperature | Maximum motor inverter temperature after ignition switch turned to ON in current trip | Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| Boosting Converter Temperature (Upper) | Boost converter temperature (upper) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Boosting Converter Temperature (Lower) | Boost converter temperature (lower) | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F):
15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 120°C (77 to 248°F) |
Inverter with converter assembly |
| Boosting Converter Temperature just after IG ON | Boost converter temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Boosting Converter Maximum Temperature | Maximum converter temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Boosting Converter Operation Request | Boost converter operation request | Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering | - | - |
| Motor Carrier Frequency | Motor (MG2) carrier frequency | 0 to 255 | - | - |
| Motor Control Mode | Motor (MG2) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode | PWM: Sine Wave
Variable PWM: Overmodulation Rectangular wave: Square Wave |
- |
| Boosting Converter Carrier Frequency | Boost converter signal carrier frequency | HI or LO | - | - |
| Boosting Converter Gate Shutdown Request | Boosting converter gate shutdown request | OFF or ON | - | - |
| Boosting Converter Shutdown Status | Boost converter shutdown status | Awake or Shutdown | Boost converter shutdown:
Shutdown Normal: Awake |
- |
| Boosting Converter Overcurrent | Boosting converter overcurrent | OFF or ON | - | - |
| Boosting Converter Input Overvoltage | Boosting converter input overvoltage | OFF or ON | - | - |
| Motor Operation Status | Motor operation status | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive | - | - |
| Motor Torque Estimate Value | Motor torque estimate value | OFF or ON | - | - |
| Motor Gate Shutdown Request | Motor gate shutdown request | OFF or ON | - | - |
| Motor Inverter Shutdown Status | Motor inverter shutdown status | OFF or ON | - | - |
| Motor Inverter Overcurrent | Motor inverter overcurrent | OFF or ON | - | - |
| VL-Voltage before Boosting | High voltage before it is boosted | - | Ignition switch ON (READY):
Practically the same as the EV supply battery voltage |
·
EV supply battery ·
Inverter with converter assembly |
| VH-Voltage after Boosting | High voltage after it is boosted | - | After boosted voltage to below approximately 600 V | Inverter with converter assembly |
| Boost Ratio | Boost converter boost ratio | Min.: 0.0%, Max.: 100.0% | - | Inverter with converter assembly |
| V Phase Motor Current | V phase motor current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| W Phase Motor Current | W phase motor current | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| DC/DC Converter Stop Request | DC/DC converter stop request | OFF or ON | OFF:
Operating ON: Stopped |
- |
| DC/DC Converter Terminal Voltage (Abnormal Detection Signal) | DC/DC converter terminal voltage (abnormal detection signal) | Min.: 0.00 V, Max.: 4.98 V | Approx. 0 V:
DC/DC stop command output from EV control ECU Approx. 2.5 V: Converter switching stopped Approx. 5 V: System operating normally |
- |
| DC/DC Converter Output Voltage Change Signal | DC/DC converter output voltage change signal | Min.: 0.00 V, Max.: 4.98 V | - | - |
| DC/DC Converter Output Voltage Change Signal Duty | DC/DC converter output voltage change signal duty | Min.: 0.0%, Max.: 127.5% | - | - |
| Inverter Coolant Water Temperature | Inverter coolant temperature | Min.: -40°C (-40°F), Max.: 110°C (230°F) | Cold start→Fully warmed up:
Gradually rises System operating normally: Controlled at 65°C (149°F) or less |
·
Inverter with converter assembly ·
Water with motor pump assembly ·
Cooling fan system ·
Inverter cooling system |
| Inverter Water Pump | Water with motor pump status | OFF or ON | Water with motor pump is operating:
ON |
Water with motor pump assembly |
| Inverter Water Pump Duty Ratio | Water with motor pump motor driver request duty | Min.: 0.0%, Max.: 100.0% | Ignition switch ON (READY):
40 to 85% |
When the water with motor pump is not operating:
200 rpm or less |
| Inverter Water Pump Revolution | Water with motor pump speed | Min.: 0 rpm, Max.: 15000 rpm | Ignition switch ON (READY):
1000 to 9300 rpm |
When the water with motor pump assembly is not operating:
200 rpm or less |
| Inverter Emergency Shutdown (Main CPU) | Inverter emergency shutdown | OFF or ON | Inverter emergency shutdown:
ON Normal: OFF |
- |
| Inverter Emergency Shutdown (Sub CPU) | Inverter emergency shutdown | OFF or ON | Inverter emergency shutdown:
ON Normal: OFF |
- |
| Inverter Input Overvoltage | Inverter input overvoltage | OFF or ON | - | - |
| Inverter Water Pump Drive Request | Water with motor pump drive request | Stop / Super Extra Low / Extra Low / Low / Middle / High | - | - |
| AC Inverter Start | AC inverter start | Able or Unable | - | - |
| Target MG Cooling Oil Pump Motor Duty | Oil with motor pump request duty | Min.: 0.0%, Max.: 100.0% | OIL PMP MTR relay ON: 15 to 85 % | - |
| MG Cooling Oil Pump Motor Speed | Oil with motor pump motor speed | Min.: 0 rpm, Max.: 65535 rpm | OIL PMP MTR relay ON: 450 to 7000 rpm | - |
| MG Cooling Oil Pump Motor Power Relay Request | OIL PMP MTR relay operation request | OFF or ON | OIL PMP MTR relay operating:
ON OIL PMP MTR relay not operating: OFF |
- |
| MG Shutdown Signal Monitor Voltage | MG shutdown signal monitor voltage | 0.0 to 4.98 V | - | - |
| Hybrid/EV Battery SOC | EV supply battery state of charge
Primary calculated from charging and discharging amperage |
Min.: 0.0%, Max.: 100.0% | Constant:
0.0 to 100.0% |
·
EV supply battery ·
Battery ECU assembly ·
EV control ECU |
| Hybrid/EV Battery SOC just after IG ON | EV supply battery state of charge soon after ignition switch ON | Min.: 0.0%, Max.: 127.5% | - | - |
| Hybrid/EV Battery Maximum SOC | Maximum SOC after ignition switch turned to ON in current trip | Min.: 0.0%, Max.: 127.5% | - | - |
| Hybrid/EV Battery Minimum SOC | Minimum SOC after ignition switch turned to ON in current trip | Min.: 0.0%, Max.: 127.5% | - | - |
| Hybrid/EV Battery Voltage | EV supply battery voltage | Min.: 0.0 V, Max.: 510.0 V | Ignition switch ON (READY):
150.0 to 300.0 V |
·
EV supply battery ·
Battery ECU assembly ·
EV control ECU |
| Hybrid/EV Battery Current | EV supply battery current | Min.: -327.68 A, Max.: 327.67 A | Ignition switch ON (READY):
-200.0 to 200.0 A |
·
EV supply battery ·
Power cable ·
Inverter with converter assembly ·
Battery current sensor |
| Hybrid/EV Battery Current for Driving Control | EV supply battery current for driving control | Min.: -327.68 A, Max.: 327.67 A | Ignition switch ON (READY):
-200.0 to 200.0 A |
- |
| Hybrid/EV Battery Control Mode | EV supply battery current mode | Driving Control Mode / Current Sensor Offset Calibration Mode / Hybrid/EV Battery External Charging Control Mode / ECU Shutdown Mode | - | - |
| Hybrid/EV Battery Maximum Temperature | EV supply battery maximum temperature | Min.: -50°C (-58°F), Max.: 205.9°C (402.6°F) | - | - |
| Hybrid/EV Battery Minimum Temperature | EV supply battery minimum temperature | Min.: -50°C (-58°F), Max.: 205.9°C (402.6°F) | - | - |
| Hybrid/EV Battery Cooling Fan Low Speed Request | Battery cooling blower assembly Lo speed requested | OFF or ON | Constant:
OFF or ON |
- |
| Short Wave Highest Value Level | Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly | Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3 | Judgment not completed:
Not Judge Normal: Normal condition Medium low level: Insulation Lower LV2 Severe low level: Insulation Lower LV3 |
High voltage circuit |
| Insulation Resistance Division Check Completion using MG Inv | Insulation Resistance Division Check Completion using MG inv | Not Complete / Complete | Decreased insulation resistance judgment for motor and FC air compressor inverter has completed:
Complete |
After turning the ignition switch from to ON (READY) to off, compare the value of Data List item "Short Wave Highest Value Level" before and after the motor and FC air compressor inverter are shut down. |
| Insulation Resistance Division Check Completion using A/C Inv | Insulation resistance division check completion using A/C inv | Not Complete / Complete | Decreased insulation resistance judgment for the air conditioning inverter has completed:
Complete |
Check the value of Data List item "Short Wave Highest Value Level" before and after the air conditioning inverter is shut down. |
| Insulation Resistance Division Check Completion using SMR | Insulation resistance division check completion using SMR | Not Complete / Complete | Decreased insulation resistance judgment for the system main relays has completed:
Complete |
Check the value of Data List item "Short Wave Highest Value Level" before and after the system main relays are turned off. |
| Short Wave Highest Value Availability just after MG Inv On/Off | Short wave highest value availability just after MG inv OFF or ON | No or Yes | The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after the motor and FC air compressor inverter are turned OFF or ON:
No |
- |
| Short Wave Highest Value Availability just after A/C Inv On/Off | Short wave highest value availability just after A/C inv OFF or ON | No or Yes | The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after air conditioning inverter turned OFF or ON.
No |
- |
| Short Wave Highest Value Availability just after SMR On/Off | Short wave highest value availability just after SMR OFF or ON | No or Yes | The value of Data List item "Short Wave Highest Value Level" cannot be checked immediately after system main relays turned OFF or ON.
No |
- |
| Hybrid/EV System Insulation Status | Hybrid system insulation status | Not Judged / Normal / Abnormal / Abnormal (Large) | - | - |
| FC Air Compressor Area Insulation Resistance Division Check Completion | FC air compressor area insulation resistance division check completion | Not Complete or Complete | - | - |
| FC Coolant Pump Area Insulation Resistance Division Check Completion | FC cooling water pump area insulation resistance division check completion | Not Complete or Complete | - | - |
| Hydrogen Pump Area Insulation Resistance Division Check Completion | Hydrogen recirculation pump area insulation resistance division check completion | Not Complete or Complete | - | - |
| FC Area Insulation Resistance Division Check Completion | FC area insulation resistance division check completion | Not Complete or Complete | - | - |
| Motor Area Insulation Resistance Division Check Completion | Motor area insulation resistance division check completion | Not Complete or Complete | - | - |
| A/C Area Insulation Resistance Division Check Completion | A/C area insulation resistance division check completion | Not Complete or Complete | - | - |
| Hybrid/EV Battery Area Insulation Resistance Division Check Completion | EV supply battery area insulation resistance division check completion | Not Complete or Complete | - | - |
| Insulation Resistance Deterioration Elapsed Time | Insulation resistance deterioration elapsed time | Min.: 0 min, Max.: 65535 min | - | - |
| Short Wave Highest Value | Short wave highest value | Min.: 0.00 V, Max.: 4.98 V | - | - |
| Immobiliser Communication | Immobiliser communication line status | OFF or ON | Ignition switch ON:
ON Immobiliser communication line malfunction: OFF |
- |
| Permit Start by Immobiliser | Status of starting permission by immobiliser (immobiliser to EV control ECU) | No Judgment / OK / NG | - | - |
| Auxiliary Battery Voltage | Auxiliary battery voltage (+B3, +B4 terminals voltage) | Min.: 0.00 V, Max.: 16.00 V | Always:
11.00 to 15.00 V |
When ignition switch ON (READY): approx. 12.5 to 15.0 V.
When ignition switch ON: same as auxiliary battery voltage (approx. 12V). If the voltage becomes 11 V or less when the ignition switch is ON (READY), the EV control ECU stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the ignition switch will not be able to be turned to ON (READY). ·
Auxiliary battery ·
DC/DC converter |
| Auxiliary Voltage | Auxiliary voltage | Min.: 0.00 V, Max.: 20.00 V | - | - |
| Auxiliary Battery Current | Auxiliary battery current | Min.: -125.00 A, Max.: 124.99 A | - | - |
| Smoothed Value of Auxiliary Battery Temperature | Smoothed value of auxiliary battery temperature | Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F) | - | - |
| Auxiliary Battery Voltage Low Times | Auxiliary battery voltage low times | Min.: 0, Max.: 255 | - | - |
| Auxiliary Battery Voltage at Low Voltage Checking Initiation | Voltage of auxiliary battery voltage low judgment | Min.: 0.00 V, Max.: 20.00 V | - | - |
| Auxiliary Battery Charging Integrated Current | Cumulative battery charging integrated current value since vehicle was built | Min.: 0.0 Ah, Max.: 429496729.5 Ah | - | - |
| Auxiliary Battery Discharging Integrated Current | Cumulative battery discharging integrated current value since vehicle was built | Min.: 0.0 Ah, Max.: 429496729.5 Ah | - | - |
| Auxiliary Battery Capacity after IG ON | Auxiliary battery capacity after IG ON | Min.: -128 Ah, Max.: 127 Ah | - | - |
| Auxiliary Battery Capacity after IG OFF | Auxiliary battery capacity after IG OFF | Min.: -128 Ah, Max.: 127 Ah | - | - |
| Auxiliary Battery Status of Full Charge | Auxiliary battery status when full charge | Min.: 0.00 Ah, Max.: 127.5 Ah | - | - |
| Auxiliary Battery Charging Rate Accuracy | Auxiliary battery charging rate accuracy | Low / Middle / High / Disable | - | - |
| Integrated Ready ON Time | Cumulative time ignition switch has been ON (READY) since vehicle was built | Min.: 0 hour, Max.: 65535 hour | - | - |
| Number of Long Term Leaving with IG OFF | Number of times ignition switch not changed from off for long period of time (1440 hours (60 days)) | Min.: 0, Max.: 255 | - | - |
| Auxiliary Battery Integrated Thermal Load | Cumulative auxiliary battery thermal load since vehicle was built | Min.: 0.0, Max.: 4294967295 | - | - |
| Auxiliary Battery Power Supply Voltage Low | Auxiliary battery power supply voltage low | OFF or ON | - | - |
| Total Distance Indicated after Long Term Leaving with IG OFF (1st) | Cumulative distance before 1st long term ignition switch off period of time (1440 hours (60 days)) | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Total Distance Indicated after Long Term Leaving with IG OFF (2nd) | Cumulative distance before 2nd long term ignition switch off period of time (1440 hours (60 days)) | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Total Distance Indicated after Long Term Leaving with IG OFF (3rd) | Cumulative distance before 3rd long term ignition switch off period of time (1440 hours (60 days)) | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Time of Long Term Leaving with IG OFF (1st) | Number of days of 1st long term ignition switch off period of time (1440 hours (60 days)) | Min.: 0 day, Max.: 255 day | - | - |
| Time of Long Term Leaving with IG OFF (2nd) | Number of days of 2nd long term ignition switch off period of time (1440 hours (60 days)) | Min.: 0 day, Max.: 255 day | - | - |
| Time of Long Term Leaving with IG OFF (3rd) | Number of days of 3rd long term ignition switch off period of time (1440 hours (60 days)) | Min.: 0 day, Max.: 255 day | - | - |
| Auxiliary Battery Average Current during IG OFF 1 Trip before | Average auxiliary battery current when ignition switch off 1 trip before | Min.: -30.000 A, Max: 1.998 A | - | - |
| Auxiliary Battery Average Current during IG OFF 2 Trip before | Average auxiliary battery current when ignition switch off 2 trip before | Min.: -30.000 A, Max: 1.998 A | - | - |
| Auxiliary Battery Average Current during IG OFF 3 Trip before | Average auxiliary battery current when ignition switch off 3 trip before | Min.: -30.000 A, Max: 1.998 A | - | - |
| Auxiliary Battery Average Current during IG OFF 4 Trip before | Average auxiliary battery current when ignition switch off 4 trip before | Min.: -30.000 A, Max: 1.998 A | - | - |
| Auxiliary Battery Average Current during IG OFF 5 Trip before | Average auxiliary battery current when ignition switch off 5 trip before | Min.: -30.000 A, Max: 1.998 A | - | - |
| Total Distance Up to 1 Trip before | Cumulative distance traveled 1 trip before | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Total Distance Up to 2 Trip before | Cumulative distance traveled 2 trip before | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Total Distance Up to 3 Trip before | Cumulative distance traveled 3 trip before | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Total Distance Up to 4 Trip before | Cumulative distance traveled 4 trip before | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| Total Distance Up to 5 Trip before | Cumulative distance traveled 5 trip before | Min.: 0 km (0 mile), Max: 131070 km (81447 mile) | - | - |
| IG OFF Time before 1 trip | Number of days ignition switch was off 1 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 2 trip | Number of days ignition switch was off 2 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 3 trip | Number of days ignition switch was off 3 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 4 trip | Number of days ignition switch was off 4 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG OFF Time before 5 trip | Number of days ignition switch was off 5 trip before | Min.: 0 day, Max.: 255 day | - | - |
| IG ON Time Up to 1 trip before | Time ignition switch was ON 1 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 2 trip before | Time ignition switch was ON 2 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 3 trip before | Time ignition switch was ON 3 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 4 trip before | Time ignition switch was ON 4 trip before | Min.: 0 min, Max.: 510 min | - | - |
| IG ON Time Up to 5 trip before | Time ignition switch was ON 5 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 1 trip before | Time ignition switch was ON (READY) 1 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 2 trip before | Time ignition switch was ON (READY) 2 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 3 trip before | Time ignition switch was ON (READY) 3 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 4 trip before | Time ignition switch was ON (READY) 4 trip before | Min.: 0 min, Max.: 510 min | - | - |
| Ready ON Time Up to 5 trip before | Time ignition switch was ON (READY) 5 trip before | Min.: 0 min, Max.: 510 min | - | - |
| FC Precharge Relay Drive Request | Actuation requests of the FC relay precharge side (FC precharge junction assembly (FRP)) | Min.: 0%, Max.: 255% | - | - |
| FC Negative Relay Drive Request | Actuation requests of the FC relay negative side (FC stack main relay (FRG)) | Min.: 0%, Max.: 255% | - | - |
| FC Positive Relay Drive Request | Actuation requests of the FC relay positive side (FC stack main relay (FRB)) | Min.: 0%, Max.: 255% | - | - |
| Radiator Fan 1 Drive Voltage | Requested voltage to the cooling fan controller with motor | Min.: 0 V, Max.: 25.5 V | 0 V:
Cooling fan stopped |
- |
| FC Air Compressor Motor Drive Speed | Drive speed of the FC air compressor with motor assembly | Min.: 0 rpm, Max.: 65535 rpm | - | - |
| FC Air Compressor Motor Speed | Motor speed of the FC air compressor with motor assembly | Min.: -32768 rpm, Max.: 32767 rpm | - | - |
| FC Air Compressor Motor Speed (Measured Value) | Measured motor speed of the FC air compressor with motor assembly | Min.: 0 rpm, Max.: 65535 rpm | 0 to 1000.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| Target FC Air Compressor Motor Speed | Target motor speed of the FC air compressor with motor assembly | Min.: -32768 rpm, Max.: 32767 rpm | - | - |
| Target Compressor Speed | Target compressor speed | Min.: 0 rpm, Max.: 65535 rpm | - | - |
| FC Start Request | Displays the FC system start command status | OFF or ON | - | - |
| FC Stop Request | Displays the FC system stop command status | None / Normal Stop / Sudden Stop / Emergency Stop | - | - |
| FC Work Mode | Mode of the FC stack operation | Stop / Finishing / Startup / Working | Stop:
Ignition switch ON |
Stop
·
FC stack has stopped operating ·
The vehicle is in READY OFF mode Startup ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied), which are located after the tank shut valve, are pressurized by supplying compressed hydrogen gas from the hydrogen tank assembly. During pressurization, high-range and low-range hydrogen pressures are monitored. Working ·
FC stack is ready to generate power. Finishing ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied) is depressurized. During depressurization, the high-range and mid-range pressures in the hydrogen supply system are monitored. |
| FC System Status | FC system status | Stop / Finishing / Startup / Working | Stop:
Ignition switch ON |
Stop
·
FC stack has stopped operating ·
The vehicle is in READY OFF mode Startup ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied), which are located after the tank shut valve, are pressurized by supplying compressed hydrogen gas from the hydrogen tank assembly. During pressurization, high-range and low-range hydrogen pressures are monitored. Working ·
FC stack is ready to generate power. Finishing ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied) is depressurized. During depressurization, the high-range and mid-range pressures in the hydrogen supply system are monitored. |
| FC Air Compressor Gate Shutdown Request | FC air compressor inverter shutdown request | OFF or ON | ON:
FC air compressor inverter shutdown request OFF: Normal |
- |
| FC Air Compressor Shutdown Status | FC air compressor inverter shutdown status | OFF or ON | ON:
FC air compressor inverter shutdown request OFF: Normal |
- |
| FC Air Compressor Consumption Power | Measure power consumption of the FC air compressor with motor assembly | Min.: 0 W, Max.: 65535 W | - | Measured power consumption of the FC air compressor with motor assembly |
| FC Air Compressor Temperature just after IG ON | FC air compressor motor temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Air Compressor Maximum Temperature | Maximum FC air compressor motor temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Air Compressor Motor Operation Status | FC air compressor motor operation status | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive | - | - |
| FC Air Compressor Motor Control Mode | FC air compressor motor control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode | - | - |
| V Phase FC Air Compressor Motor Current | FC air compressor motor phase V current value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| W Phase FC Air Compressor Motor Current | FC air compressor motor phase W current value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| FC Air Compressor Motor Carrier Frequency | FC air compressor motor carrier frequency | 0 to 255 | - | - |
| FC Air Compressor Motor Temperature | FC air compressor motor temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | 25°C (77°F):
Vehicle left for 1 day at an ambient temperature of 25°C (77°F) 25 to 120°C (77 to 248°F): While driving at an ambient temperature of 25°C (77°F) |
AMT terminal signal |
| FC Air Compressor Motor Temperature (Filtered Value) | FC air compressor motor temperature filtered value | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | - | - |
| FC Air Compressor Motor Torque Estimate Value | FC air compressor motor torque estimate value | Min.: -4096 Nm, Max.: 4095.87 Nm | - | - |
| FC Air Compressor Inverter Shutdown Status | FC air compressor inverter shutdown | OFF or ON | ON:
FC air compressor inverter shutdown OFF: Normal |
- |
| FC Air Compressor Inverter Stop | FC air compressor inverter stopped | OFF or ON | ON:
FC air compressor inverter stopped OFF: Normal |
- |
| FC Air Compressor Inverter Maximum Temperature | Maximum FC air compressor inverter temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Air Compressor Inverter Overcurrent | Overcurrent detection into FC air compressor inverter | OFF or ON | ON:
Overcurrent is detected into FC air compressor inverter OFF: Normal |
- |
| FC Air Compressor Inverter Temperature | FC air compressor inverter temperature filtered value | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | - | - |
| FC Air Compressor Inverter Temperature (Filtered Value) | FC air compressor inverter temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | - | - |
| FC Air Compressor Inverter Temperature just after IG ON | FC air compressor inverter temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Main Relay Connect | Main relay connect | OFF or ON | - | - |
| FC Precharge Relay Request | FC relay precharge side (FC precharge junction assembly (FRP)) activation request status | OFF or ON | - | - |
| FC Negative Relay Request | FC relay negative side (FC stack main relay (FRG)) activation request status | OFF or ON | - | - |
| FC Positive Relay Request | FC relay positive side (FC stack main relay (FRB)) activation request status | OFF or ON | - | - |
| FC Precharge Relay Control Status | FC relay precharge side (FC precharge junction assembly (FRP)) request status | OFF or ON | - | - |
| FC Precharge Relay Status | FC relay precharge side (FC precharge junction assembly (FRP)) operation status | OFF or ON | - | - |
| FC Positive Relay Drive Signal Voltage | FC relay positive side (FC stack main relay (FRB)) drive signal voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| FC Positive Relay Drive Status | FC relay positive side (FC stack main relay (FRB)) operation status | Shutdown / Inrush / Keep | - | - |
| FC Negative Relay Drive Signal Voltage | FC relay negative side (FC stack main relay (FRG)) drive signal voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| FC Negative Relay Drive Status | FC relay negative side (FC stack main relay (FRG)) operation status | Shutdown / Inrush / Keep | - | - |
| FC Interlock Switch | FC interlock switch condition | OFF or ON | Ignition switch ON, FC converter power outlet cable not installed:
ON |
- |
| FCDC Input Voltage | FC boost converter (FC converter power module transistor) input voltage sensor value | Min.: 0 V, Max.: 6553.5 V | 0 to 330 V:
Ignition switch ON (READY) |
Value of the FVL sensor located inside the FC boost converter |
| FCDC Output Voltage | FC boost converter (FC converter power module transistor) output voltage sensor value | Min.: 0 V, Max.: 6553.5 V | 0 to 330 V:
Ignition switch ON (READY) |
Value of the FVL sensor located inside the FC boost converter |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).
After performing the Active Test, turn the ignition switch off before proceeding to the next step.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / EV / Active Test.
According to the display on the GTS perform the appropriate Active Test.
| Tester Display | Measurement Item | Control Range | Restrict Condition | Diagnostic Note |
|---|---|---|---|---|
| Hybrid/EV Battery Charge | To charge the EV supply battery using the THS charger | ON / OFF | Ignition switch ON, shift state in park (P), other Active Tests not being performed, auxiliary battery voltage is 9.5 V or more and DTCs are not output | ·
Test Details Allows current to flow into the EV supply battery by operating the SMRs ·
When DTCs are memorized, complete the repairs of those DTCs and then clear the DTCs |
| Activate the Inverter Water Pump | To activate the water with motor pump assembly continuously | ON / OFF | Ignition switch ON, hybrid control system normal, not in maintenance mode, and other Active Tests not being performed, auxiliary battery voltage is 9.5 V or more | ·
Test Details Before performing the Active Test of the water with motor pump assembly, check the coolant level. Related Data List
-
Inverter Coolant Water Temperature -
Inverter Water Pump -
Inverter Water Pump Duty Ratio -
Inverter Water Pump Revolution -
Auxiliary Battery Voltage |
| Connect the TC and TE1 | Batch display of warnings on combination meter assembly | ON / OFF | Ignition switch ON | ·
Test Details TC terminal can be switched ON or OFF |
| Control the Motor/Generator Cooling Oil Pump | Operate the oil pump with motor assembly | 0 to 100%*2 | Ignition switch ON or (READY), engine stopped, hybrid control system normal, after warming up | ·
Operation begins 3 seconds after starting the Active Test. ·
Maximum operation duration: 30 seconds [Current Value] Not Active or Active or Complete or Abort |
| Control the Radiator Fan 1 | Drive the cooling fan controller with motor | 0.1 to 13.7 V | Ignition switch ON | ·
Control Range 0.1 to 13.7 V ·
Visually check or listen to sound for the radiator fan operation. |
| Activate the FC Precharge Relay | Operation checks for the FC relay precharge side (FC precharge junction assembly (FRP)) | OFF / ON | ·
Ignition switch ON ·
SMR (System Main Relay) is not connected ·
BATT Voltage is below 10 V |
·
FC precharge junction assembly (FRP) forced actuation is allowed for one side only ·
If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur. Relating Data List items:
-
SMRB Status -
SMRG Status -
FCDC Input Voltage -
FC Positive Relay Drive Request -
FC Negative Relay Drive Request -
FC Precharge Relay Drive Request |
| Activate the FC Negative Relay | Operation checks for the FC relay negative side (FC stack main relay (FRG)) | OFF / ON | ·
Ignition switch ON ·
SMR (System Main Relay) is not connected ·
BATT Voltage is below 10 V |
·
FC stack main relay (FRG) forced actuation is allowed for one side only ·
If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur. Relating Data List items:
-
SMRB Status -
SMRG Status -
FCDC Input Voltage -
FC Positive Relay Drive Request -
FC Negative Relay Drive Request -
FC Precharge Relay Drive Request |
| Activate the FC Positive Relay | Operation checks for the FC relay positive side (FC stack main relay (FRB)) | OFF / ON | ·
Ignition switch ON ·
SMR (System Main Relay) is not connected ·
BATT Voltage is below 10 V |
·
FC stack main relay (FRB) forced actuation is allowed for one side only ·
If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur. Relating Data List items:
-
SMRB Status -
SMRG Status -
FCDC Input Voltage -
FC Positive Relay Drive Request -
FC Negative Relay Drive Request -
FC Precharge Relay Drive Request |
| Control the FC Air Compressor | Drive the FC air compressor with motor assembly to a requested motor speed | 0 to 5000 rpm | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the data list shows Normal or Intermittent ·
For 60 seconds after an Active Test is requested |
·
Control Range 100 to 16700 rpm ·
Related Data List -
FC Air Compressor Motor Drive Speed -
FC Air Compressor Motor Speed -
Target FC Air Compressor Motor Speed -
FC Air Compressor Motor Speed (Measured Value) ·
"FC Air Compressor Motor Speed" is normally within a "Target FC Air Compressor Motor Speed" +/-200 rpm (e.g. 2000 +/-200 rpm) ·
Operating sound can be heard from the operating FC air compressor with motor assembly ·
If an air pressure increases too high due to forced continuous revolution increase in the compressor, it will be interpreted as a malfunction.
|
*1: The GTS will display a communication error and the vehicle's READY indicator will turn off when the Active Test is completed. If the GTS will be used on the vehicle again, turn the ignition switch off and then to ON (READY) again to restart the GTS.
*2: The active test is not performed when the Duty ratio 50 % or lower or 95 % or higher, or the ambient temperature is 11 °C (51.8 °F) or lower.
Starting to charge the EV supply battery while cranking the engine: When the Active Test is complete, a communication error is displayed on the GTS and the vehicle enters the READY off state. Therefore, when using the GTS again after turning the ignition switch off, turn the ignition switch to ON (READY) and restart the GTS.