1.INSPECT H-LP LH RELAY
Inspect the H-LP LH relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the H-LP LH relay.
2.INSPECT H-LP RH RELAY
Inspect the H-LP RH relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Auxiliary battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the H-LP RH relay.