The blower with fan motor sub-assembly reads the signal from the air conditioning amplifier assembly and controls operation and speed changes of the blower motor.
If the blower air volume is weak, or there are any other blower malfunctions such as the temperature or air volume cannot be changed, the following causes are possible.
| Symptom | Factor |
|---|---|
| Blower airflow volume cannot be changed | ·
Air conditioning amplifier assembly malfunction ·
Blower with fan motor sub-assembly malfunction ·
Wire harness or connector |
Inspect the fuses for circuits related to this system before performing the following procedure.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0
Max.: 31 |
- |
| Tester Display |
|---|
| Blower Motor |
| Result | Proceed to |
|---|---|
| Blower motor with fan sub-assembly does not operate | A |
| Blower motor with fan sub-assembly operates but does not change speed | B |
A
B
Disconnect the blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A13)Location & Routingewd_type=routing;type=c;code=A13 Click Connector(A13)Instrument Panel>Front Compartment Main Wire>Blower Motor with Fan Sub-Assemblyewd_type=component;type=c;code=A13;pinno=1 |
||
| A13-1 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A13)Location & Routingewd_type=routing;type=c;code=A13 Click Connector(A13)Instrument Panel>Front Compartment Main Wire>Blower Motor with Fan Sub-Assemblyewd_type=component;type=c;code=A13;pinno=3 |
||
| A13-3 (+B) - Body ground | Ignition switch off | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D81 air conditioning amplifier assembly connector.
Disconnect the A13 blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D81,A13)Location & Routingewd_type=routing;type=c,c;code=D81,A13 Click Connector(D81)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D81;pinno=21 Click Connector(A13)Instrument Panel>Front Compartment Main Wire>Blower Motor with Fan Sub-Assemblyewd_type=component;type=c;code=A13;pinno=2 |
||
| D81-21 (BLW) - A13-2 (SI) | Always | Below 1 Ω |
| D81-21 (BLW) or A13-2 (SI) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D81 air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D81)Location & Routingewd_type=routing;type=c;code=D81 Click Connector(D81)Instrument Panel>Instrument Panel Wire>Air Conditioning Amplifier Assemblyewd_type=component;type=c;code=D81;pinno=21 |
||
| D81-21 (BLW) - Body ground | Always | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Blower with Fan Motor Sub-assembly) |
Using the oscilloscope, check for the waveform.
| Terminal No. | Tool Setting | Condition |
|---|---|---|
| A13-2 (SI) - Body ground | 1 V/DIV., 500 μs./DIV. | ·
Ignition switch ON ·
Blower switch: LO |
The waveform varies with the blower speed.
Waveform is similar to that shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Using an oscilloscope, check the waveform.
| Terminal No. | Tool Setting | Condition |
|---|---|---|
| D81-21 (BLW) - D81-17 (GND) | 2 V/DIV., 1 ms./DIV. | ·
Ignition switch ON ·
Blower speed: LO |
Waveform is similar to that shown in the illustration.
The waveform varies with the blower speed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG