DESCRIPTION
The EV control ECU, FC control ECU, FC boost control ECU and hydrogen fuel control ECU assembly have a self-diagnosis system. If the computer, FC control system, or a component is not working properly, the ECU records the conditions that relate to the fault. The ECU also illuminates the master warning light in the combination meter assembly and provides other appropriate messages on the multi-information display, such as the FC system warning message, EV supply battery assembly warning message.
The EV control ECU detects hydrogen gas via the hydrogen detector and monitors for hydrogen leakage to the outside. If the hydrogen detector detects hydrogen gas, it illuminates the hydrogen leak warning light and master warning light and at the same time displays a warning message on the multi-information display.
In situations when the vehicle is driven under heavy load or other operating conditions which make it difficult for the FC system to provide optimal output to the vehicle, the output power may be temporarily restricted. When output power is restricted due to high FC system temperature, the power restriction indicator will illuminate in amber, and when due to low FC system temperature it will illuminate in blue.
2 TRIP DETECTION LOGIC
When a malfunction is first detected, the malfunction is temporarily stored in the EV control ECU memory (1st trip). If the same malfunction is detected during the next drive cycle, the master warning light is illuminated (2nd trip).
FREEZE FRAME DATA
The EV control ECU, FC control ECU, FC boost control ECU and hydrogen fuel control ECU assembly records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was moving or stationary, whether the FC system was warmed up or not, as well as other data recorded at the time of a malfunction.
AUXILIARY BATTERY VOLTAGE
| Switch Condition | Specified Condition |
|---|---|
| Ignition switch ON | 11 to 14 V |
If voltage is below 11 V, recharge or replace the auxiliary battery.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY