VEHICLE BEHAVIOR CHART
Vehicle behavior categorized by DTC
If a DTC is output, the vehicle behaves as follows.
| DTC No. | Detection Item | Vehicle Behavior when DTC is Output | DTC Output from |
|---|---|---|---|
| P009A62 | Intake Air Temperature/Ambient Air Temperature Correlation Signal Compare Failure | Normal driving | EV |
| P010031 | Mass or Volume Air Flow Sensor "A" No Signal | Operating pattern 2 (*2) | EV |
| P011011 | Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground | Normal driving | EV |
| P011015 | Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Battery or Open | Normal driving | EV |
| P060B16 | Internal Control Module A/D Processing Performance Circuit Voltage Below Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P060B1C | Internal Control Module A/D Processing Performance Circuit Voltage Out of Range | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P060B1C | Internal Control Module A/D Processing Performance Circuit Voltage Out of Range | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P060B49 | Internal Control Module A/D Processing Performance Internal Electronic Failure | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P060B49 | Internal Control Module A/D Processing Performance Internal Electronic Failure | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P060B71 | Internal Control Module A/D Processing Performance Actuator Stuck | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P060B71 | Internal Control Module A/D Processing Performance Actuator Stuck | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P062F00 | Internal Control Module EEPROM Error | Normal driving | EV |
| P19FD73 | Air Conditioner Power Supply Relay Actuator Stuck Closed | Normal driving | EV |
| P1D0618 | FC Converter Phase U Current Circuit Current Below Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D0619 | FC Converter Phase U Current Circuit Current Above Threshold | Reduced output power | FCDC |
| P1D0718 | FC Converter Phase V Current Circuit Current Below Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D0719 | FC Converter Phase V Current Circuit Current Above Threshold | Reduced output power | FCDC |
| P1D0818 | FC Converter Phase W Current Circuit Current Below Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D0819 | FC Converter Phase W Current Circuit Current Above Threshold | Reduced output power | FCDC |
| P1D0918 | FC Converter Phase X Current Circuit Current Below Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D0919 | FC Converter Phase X Current Circuit Current Above Threshold | Reduced output power | FCDC |
| P1D0E62 | Inverter Output Voltage/FC Converter Output Voltage Signal Compare Failure | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D1C16 | FC Converter Output Voltage Sensor Circuit Voltage Below Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D1C17 | FC Converter Output Voltage Sensor Circuit Voltage Above Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D2017 | FC Converter Input Voltage Sensor Circuit Voltage Above Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1D2496 | Hydrogen Pump Component Internal Failure | Operating pattern 2 (*2) | EV |
| P1D2511 | Radiator Outlet Coolant Temperature Sensor Circuit Short to Ground | Normal driving | EV |
| P1D2515 | Radiator Outlet Coolant Temperature Sensor Circuit Short to Battery or Open | Normal driving | EV |
| P1D251C | Radiator Outlet Coolant Temperature Sensor Circuit Voltage Out of Range | Normal driving | EV |
| P1D2A11 | FC Stack Outlet Coolant Temperature Sensor Circuit Short to Ground | Operating pattern 2 (*2) | EV |
| P1D2A15 | FC Stack Outlet Coolant Temperature Sensor Circuit Short to Battery or Open | Operating pattern 2 (*2) | EV |
| P1D2A1C | FC Stack Outlet Coolant Temperature Sensor Circuit Voltage Out of Range | Operating pattern 2 (*2) | EV |
| P1D2F00 | FC Coolant Pump Performance | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1D2F96 | FC Coolant Pump Component Internal Failure | FC cooling water pump speed abnormal:
Operating pattern 2 (*2) FC cooling water pump stopped: FC system stopped |
EV |
| P1D3011 | Phase U Reactor Current Sensor Circuit Short to Ground | Reduced output power | FCDC |
| P1D3015 | Phase U Reactor Current Sensor Circuit Short to Battery or Open | Reduced output power | FCDC |
| P1D301C | Phase U Reactor Current Sensor Circuit Voltage Out of Range | Reduced output power | FCDC |
| P1D3028 | Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Reduced output power | FCDC |
| P1D3511 | Phase V Reactor Current Sensor Circuit Short to Ground | Reduced output power | FCDC |
| P1D3515 | Phase V Reactor Current Sensor Circuit Short to Battery or Open | Reduced output power | FCDC |
| P1D351C | Phase V Reactor Current Sensor Circuit Voltage Out of Range | Reduced output power | FCDC |
| P1D3528 | Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Reduced output power | FCDC |
| P1D3A11 | Phase W Reactor Current Sensor Circuit Short to Ground | Reduced output power | FCDC |
| P1D3A15 | Phase W Reactor Current Sensor Circuit Short to Battery or Open | Reduced output power | FCDC |
| P1D3A1C | Phase W Reactor Current Sensor Circuit Voltage Out of Range | Reduced output power | FCDC |
| P1D3A28 | Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Reduced output power | FCDC |
| P1D3F16 | FC Stack Internal Voltage Circuit Voltage Below Threshold | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1D4011 | Phase X Reactor Current Sensor Circuit Short to Ground | Reduced output power | FCDC |
| P1D4015 | Phase X Reactor Current Sensor Circuit Short to Battery or Open | Reduced output power | FCDC |
| P1D401C | Phase X Reactor Current Sensor Circuit Voltage Out of Range | Reduced output power | FCDC |
| P1D4028 | Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Reduced output power | FCDC |
| P1D4512 | Phase U Temperature Sensor Circuit Short to Battery | Reduced output power | FCDC |
| P1D4514 | Phase U Temperature Sensor Circuit Short to Ground or Open | Reduced output power | FCDC |
| P1D4A12 | Phase V Temperature Sensor Circuit Short to Battery | Reduced output power | FCDC |
| P1D4A14 | Phase V Temperature Sensor Circuit Short to Ground or Open | Reduced output power | FCDC |
| P1D4F62 | Total Reactor Current/FC Current Signal Compare Failure | Normal driving | FCDC |
| P1D5012 | Phase W Temperature Sensor Circuit Short to Battery | Reduced output power | FCDC |
| P1D5014 | Phase W Temperature Sensor Circuit Short to Ground or Open | Reduced output power | FCDC |
| P1D5512 | Phase X Temperature Sensor Circuit Short to Battery | Reduced output power | FCDC |
| P1D5514 | Phase X Temperature Sensor Circuit Short to Ground or Open | Reduced output power | FCDC |
| P1D5F87 | Lost Communication with Cell Monitor Missing Message | FC system output limited to 10 kW | FCDC |
| P1D7F62 | FC Air Compressor Motor Signal Compare Failure | Operating pattern 1 (*1) | EV |
| P1D7F96 | FC Air Compressor Motor Component Internal Failure | Operating pattern 1 (*1) | EV |
| P1D8387 | Lost Communication with Hydrogen Pump Inverter Missing Message | Operating pattern 2 (*2) | EV |
| P1D8396 | Hydrogen Pump Inverter Component Internal Failure | Operating pattern 2 (*2) | EV |
| P1D8511 | Hydrogen Pump Motor Temperature Sensor Circuit Short to Ground | Operating pattern 1 (*1) | EV |
| P1D8515 | Hydrogen Pump Motor Temperature Sensor Circuit Short to Battery or Open | Operating pattern 1 (*1) | EV |
| P1D8A11 | FC Inter Cooler Outlet Temperature Sensor Circuit Short to Ground | Operating pattern 1 (*1) | EV |
| P1D8A15 | FC Inter Cooler Outlet Temperature Sensor Circuit Short to Battery or Open | Operating pattern 1 (*1) | EV |
| P1D8F00 | FC Air Compressor Motor Control Module Performance | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1D9011 | FC Stack Inlet Pressure Sensor Circuit Short to Ground | Operating pattern 1 (*1) | EV |
| P1D9015 | FC Stack Inlet Pressure Sensor Circuit Short to Battery or Open | Operating pattern 1 (*1) | EV |
| P1D9A1C | Hydrogen Injector 1 Circuit Voltage Out of Range | Normal driving | FC |
| P1DA01C | Hydrogen Injector 2 Circuit Voltage Out of Range | Normal driving | FC |
| P1DA51C | Hydrogen Injector 3 Circuit Voltage Out of Range | Normal driving | FC |
| P1DAA12 | Exhaust Drainage Valve Circuit Short to Battery | Operating pattern 2 (*2) | FC |
| P1DAA14 | Exhaust Drainage Valve Circuit Short to Ground or Open | Operating pattern 1 (*1) | FC |
| P1DB011 | High-Range Hydrogen Pressure Sensor Circuit Short to Ground | Normal driving | FC |
| P1DB015 | High-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | Normal driving | FC |
| P1DB01C | High-Range Hydrogen Pressure Sensor Circuit Voltage Out of Range | Normal driving | EV |
| P1DB511 | Medium-Range Hydrogen Pressure Sensor Circuit Short to Ground | Normal driving | FC |
| P1DB515 | Medium-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | Normal driving | FC |
| P1DBA11 | Low-Range Hydrogen Pressure Sensor Circuit Short to Ground | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1DBA15 | Low-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1DC000 | Low-Range Hydrogen Pressure Too Low | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1DC100 | Low-Range Hydrogen Pressure Too High | Operating pattern 2 (*2) | EV |
| P1DC300 | Medium-Range Hydrogen Pressure Too High | Operating pattern 2 (*2) | EV |
| P1DC500 | FC Air Pressure Too High | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1DC618 | Air Sealing Valve Circuit Current Below Threshold | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1DC619 | Air Sealing Valve Circuit Current Above Threshold | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1DC711 | Air Sealing Valve Position Sensor Circuit Short to Ground | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1DC715 | Air Sealing Valve Position Sensor Circuit Short to Battery or Open | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1DC887 | Lost Communication with FC Coolant Pump Inverter Missing Message | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1DC896 | FC Coolant Pump Inverter Component Internal Failure | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1DCA31 | Hydrogen Detector (Motor Room) No Signal | Normal driving | EV |
| P1DCF96 | Cell Monitor Component Internal Failure | Operating pattern 2 (*2) | EV |
| P1DD031 | Hydrogen Detector Sensor "A" No Signal | Normal driving | EV |
| P1DD514 | Radiator Rotary Valve Circuit 1 Circuit Short to Ground or Open | Operating pattern 1 (*1) | FC |
| P1DDA00 | FC Converter Phase U Performance | Reduced output power | FCDC |
| P1DDA4B | FC Converter Phase U Over Temperature | Reduced output power | FCDC |
| P1DDA9E | FC Converter Phase U Fail Signal Stuck On | Reduced output power | FCDC |
| P1DDB00 | FC Converter Phase V Performance | Reduced output power | FCDC |
| P1DDB4B | FC Converter Phase V Over Temperature | Reduced output power | FCDC |
| P1DDB9E | FC Converter Phase V Fail Signal Stuck On | Reduced output power | FCDC |
| P1DDC00 | FC Converter Phase W Performance | Reduced output power | FCDC |
| P1DDC4B | FC Converter Phase W Over Temperature | Reduced output power | FCDC |
| P1DDC9E | FC Converter Phase W Fail Signal Stuck On | Reduced output power | FCDC |
| P1DDD00 | FC Converter Phase X Performance | Reduced output power | FCDC |
| P1DDD4B | FC Converter Phase X Over Temperature | Reduced output power | FCDC |
| P1DDD9E | FC Converter Phase X Fail Signal Stuck On | Reduced output power | FCDC |
| P1DDE31 | Hydrogen Detector Sensor "B" No Signal | Normal driving | EV |
| P1DDF00 | FC Air Flow Malfunction | Operating pattern 2 (*2) | EV |
| P1DDF79 | FC Air Flow Mechanical Linkage Failure | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1DE400 | FC Cooling System Performance | FC cooling system abnormal:
Operating pattern 2 (*2) FC stack outlet coolant temperature increased abnormally: FC system stopped |
EV |
| P1DE511 | Hydrogen Tank 1 Temperature Sensor Circuit Short to Ground | Normal driving | Hydrogen Filling Control |
| P1DE515 | Hydrogen Tank 1 Temperature Sensor Circuit Short to Battery or Open | Normal driving | Hydrogen Filling Control |
| P1DE51C | Hydrogen Tank 1 Temperature Sensor Circuit Voltage Out of Range | Normal driving | EV |
| P1DEA11 | Hydrogen Tank 2 Temperature Sensor Circuit Short to Ground | Normal driving | Hydrogen Filling Control |
| P1DEA15 | Hydrogen Tank 2 Temperature Sensor Circuit Short to Battery or Open | Normal driving | Hydrogen Filling Control |
| P1DEF00 | FC System No Activation | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1DFA11 | Hydrogen Intake Pressure Sensor Circuit Short to Ground | Normal driving | Hydrogen Filling Control |
| P1DFA15 | Hydrogen Intake Pressure Sensor Circuit Short to Battery or Open | Normal driving | Hydrogen Filling Control |
| P1E0012 | Tank Shut Valve 1 Circuit Short to Battery | Normal driving | Hydrogen Filling Control |
| P1E0014 | Tank Shut Valve 1 Circuit Short to Ground or Open | Normal driving | Hydrogen Filling Control |
| P1E1012 | Tank Shut Valve 2 Circuit Short to Battery | Normal driving | Hydrogen Filling Control |
| P1E1014 | Tank Shut Valve 2 Circuit Short to Ground or Open | Normal driving | Hydrogen Filling Control |
| P1E1996 | Infrared Transmitter Component Internal Failure | Normal driving | Hydrogen Filling Control |
| P1E367E | Tank Shut Valve 1 Actuator Stuck On | Normal driving | EV |
| P1E4000 | Extreme Hydrogen Leak (Motor Room) | When a detected hydrogen concentration is more than 3%:
FC system stopped (Mode enters EV drive mode, and travel distance will be limited) |
EV |
| P1E407A | Hydrogen Leak (Motor Room) Fluid Leak or Seal Failure | When a detected hydrogen concentration is 2 to 3%:
Normal driving |
EV |
| P1E4100 | Extreme Hydrogen Leak (Tank Area 1) | When a detected hydrogen concentration is more than 3%:
FC system stopped (Mode enters EV drive mode, and travel distance will be limited) |
EV |
| P1E417A | Hydrogen Leak (Tank Area 1) Fluid Leak or Seal Failure | When a detected hydrogen concentration is 2 to 3%:
Normal driving |
EV |
| P1E427A | Hydrogen Leak (Excessive Hydrogen Flow) Fluid Leak or Seal Failure | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E437A | Hydrogen Leak (High/Medium Pressure Area) Fluid Leak or Seal Failure | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E447A | Hydrogen Leak (Low Pressure Area) Fluid Leak or Seal Failure | Operating pattern 2 (*2) | EV |
| P1E4862 | FC Stack Inlet Pressure Sensor/Barometric Pressure Sensor "B" Signal Compare Failure | When the FC stack inlet air pressure sensor (vacuum sensor assembly) is abnormal:
Operating pattern 1 (*1) When the atmosphere pressure sensor is abnormal: Normal driving |
EV |
| P1E4A11 | Hydrogen Tank 3 Temperature Sensor Circuit Short to Ground | Normal driving | Hydrogen Filling Control |
| P1E4A15 | Hydrogen Tank 3 Temperature Sensor Circuit Short to Battery or Open | Normal driving | Hydrogen Filling Control |
| P1E5A12 | Tank Shut Valve 3 Circuit Short to Battery | Normal driving | Hydrogen Filling Control |
| P1E5A14 | Tank Shut Valve 3 Circuit Short to Ground or Open | Normal driving | Hydrogen Filling Control |
| P1E6B73 | Fuel Lid Interlock Actuator Stuck Closed | Normal driving | EV |
| P1E7A18 | Air Shunt Valve Circuit Current Below Threshold | Normal driving | FC |
| P1E7A19 | Air Shunt Valve Circuit Current Above Threshold | Normal driving | FC |
| P1E7B11 | Air Shunt Valve Position Sensor Circuit Short to Ground | Normal driving | FC |
| P1E7B15 | Air Shunt Valve Position Sensor Circuit Short to Battery or Open | Normal driving | FC |
| P1E7C18 | Air Pressure Regulating Valve Circuit Current Below Threshold | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1E7C19 | Air Pressure Regulating Valve Circuit Current Above Threshold | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1E7D11 | Air Pressure Regulating Valve Position Sensor Circuit Short to Ground | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1E7D15 | Air Pressure Regulating Valve Position Sensor Circuit Short to Battery or Open | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1E7E87 | Lost Communication with Hybrid/EV Powertrain Control Module (SIL) Missing Message | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | FC |
| P1E7F87 | Communication Error from Fuel Cell Control Module to Hybrid/EV Powertrain Control Module Missing Message | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E9011 | FC Positive Contactor Control Circuit Short to Ground | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E9015 | FC Positive Contactor Control Circuit Short to Battery or Open | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E9111 | FC Negative Contactor Control Circuit Short to Ground | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E9115 | FC Negative Contactor Control Circuit Short to Battery or Open | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E9211 | FC Precharge Contactor Control Circuit Short to Ground | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1E9215 | FC Precharge Contactor Control Circuit Short to Battery or Open | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1EF214 | Air Valve Supply Voltage Circuit Short to Ground or Open | Normal driving | FC |
| P1EF394 | Fuel Cell Control Module Unexpected Operation | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| P1EF581 | Invalid Data Received from Water Heating Heater Invalid Serial Data Received | Normal driving | EV |
| P1EF600 | Extreme Hydrogen Leak (Tank Area 2) | When a detected hydrogen concentration is more than 3%:
FC system stopped (Mode enters EV drive mode, and travel distance will be limited) |
EV |
| P1EF67A | Hydrogen Leak (Tank Area 2) Fluid Leak or Seal Failure | When a detected hydrogen concentration is 2 to 3%:
Normal driving |
EV |
| P1EFD14 | Radiator Rotary Valve Circuit 2 Circuit Short to Ground or Open | Operating pattern 1 (*1) | FC |
| P1EFE14 | Radiator Rotary Valve Circuit 3 Circuit Short to Ground or Open | Operating pattern 1 (*1) | FC |
| P1EFF14 | Radiator Rotary Valve Circuit 4 Circuit Short to Ground or Open | Operating pattern 1 (*1) | FC |
| P1F009E | FC Converter Overvoltage Signal Stuck On | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1F0117 | FC Converter Output Voltage Circuit Voltage Above Threshold | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1F089F | FC Shutdown Signal Stuck Off | Normal driving (if abnormality/malfunction continues for 10 hours, restart will be prohibited from the next time) | EV |
| P1F451F | FC Converter Control Module Power Relay Sense Circuit Intermittent | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1F4A1F | Fuel Cell Control Module Power Relay Sense Circuit Intermittent | Normal driving | FC |
| P1F651C | FC Converter Control Module Power Supply (-5V) Circuit Voltage Out of Range | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1F661C | FC Converter Control Module Power Supply (+V5AREF) Circuit Voltage Out of Range | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| P1F6C71 | Air Sealing Valve Actuator Stuck | Considerable decrease in output. However, the FC system transitions to stopped (transitions to EV driving but with limited cruising distance) due to the malfunction mode | EV |
| P1F6D71 | Air Shunt Valve Actuator Stuck | Greatly reduced output power | EV |
| P1F6E71 | Air Pressure Regulating Valve Actuator Stuck | Considerable decrease in output. However, the FC system transitions to stopped (transitions to EV driving but with limited cruising distance) due to the malfunction mode | EV |
| P222A12 | Barometric Pressure Sensor "B" Circuit Short to Battery | Normal driving | EV |
| P222A14 | Barometric Pressure Sensor "B" Circuit Short to Ground or Open | Normal driving | EV |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | Hydrogen Filling Control |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | ·
Greatly reduced output power ·
FC system stopped ·
Driving range is limited |
FCDC |
| U116087 | Lost Communication with FCDC Control Module Missing Message | FC system stopped (Mode enters EV drive mode, and travel distance will be limited) | EV |
| U116287 | Lost Communication with Hydrogen Filling Control Module Missing Message | Normal driving | EV |
| U149257 | Software incompatibility with Hybrid/EV Powertrain Control Module Invalid/Incompatible Software Component | Normal driving | Hydrogen Filling Control |
1. Reduced output power
- If an abnormality continues for 1 minute, go to 2
- 60 km/h (37 mph), or less, immediately go to 2.
2. Greatly reduced output power
- If an abnormality continues for 1 hour, go to 3.
3. FC system stopped (Mode enters EV drive mode, and travel distance will be limited)
1. Greatly reduced output power
- If an abnormality continues for 1 hour, go to 2.
2. FC system stopped (Mode enters EV drive mode, and travel distance will be limited)
Relationship between the above and the multi-information display
| Multi-information Display | Vehicle behavior categorized by DTC |
|---|---|
| FC System Malfunction Visit Your Dealer | Normal driving |
| FC System Malfunction Stop in a Safe Place Contact Your Dealer | Other than above. |