Home › General › SPECIFICATIONS › HYBRID / BATTERY CONTROL
RM37H0E _V1 General _095078 SPECIFICATIONS _0466777 HYBRID / BATTERY CONTROL F

SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Coolant (for Inverter)
Item Specified Condition
Standard Value (for Brand-new Cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 14 to 17 psi)
Minimum Standard Value (for Used Cap) 94 kPa (1.0 kgf/cm2, 14 psi)

Relay
Item Tester Connection Specified Condition
Ignition Contact Relay (IGCT No. 1)
Resistance
3 - 5 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2)
Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2)
Ignition Contact Relay (IGCT No. 2)
Resistance
3 - 5 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2)
Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2)
INV Water Pump Relay (INV W/PMP)
Resistance
3 - 5 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2)
Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2)
Battery Fan Relay (BATT FAN)
Resistance
3 - 5 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2)
Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2)

No. 1 EV Battery Junction Block Assembly
Item Tester Connection Condition Specified Condition
SMRB
Resistance
N1-1 (CBI) - z13-1 (+) Auxiliary battery voltage not applied between terminals z24-1 (SMRB) and z24-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals z24-1 (SMRB) and z24-3 (GND) Below 1 Ω
z24-1 (SMRB) - z24-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω
SMRG
Resistance
N2-1 (CEI) - z12-1 (-) Auxiliary battery voltage not applied between terminals z24-4 (SMRG) and z24-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals z24-4 (SMRG) and z24-3 (GND) Below 1 Ω
z24-4 (SMRG) - z24-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω
SMRP
Resistance
N2-1 (CEI) - z12-1 (-) Auxiliary battery voltage not applied between terminals z24-2 (SMRP) and z24-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals z24-2 (SMRP) and z24-3 (GND) 24.3 to 29.7 Ω
z24-2 (SMRP) - z24-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω

PATTERN SELECT SWITCH
No. 1 pattern select switch assembly (DRIVE MODE):
Tester Connection Condition Specified Condition
D5-1 (DMS+) - D5-3 (E) When the DRIVE MODE switch is operated and held on the top side Below 10 Ω
D5-1 (DMS+) - D5-3 (E)
D5-4 (DMS-) - D5-3 (E)
When the DRIVE MODE switch is not operated 10 kΩ or higher
D5-4 (DMS-) - D5-3 (E) When the DRIVE MODE switch is operated and held on the bottom side Below 10 Ω

No. 1 pattern select switch assembly (DRIVE MODE):
Measurement Condition Specified Condition
Battery positive (+) → D5-5 (ILL+)
Battery negative (-) → D5-2 (ILL-)
Illuminates

Service Plug Grip
Tester Connection Condition Specified Condition
Service plug grip Always Below 1 Ω

Fuse Box
Tester Connection Condition Specified Condition
EV Battery Terminal Block Always Below 1 Ω