| Item | Specified Condition |
| Standard Value (for Brand-new Cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 14 to 17 psi) |
| Minimum Standard Value (for Used Cap) | 94 kPa (1.0 kgf/cm2, 14 psi) |
| Item | Tester Connection | Specified Condition |
| Ignition Contact Relay (IGCT No. 1)
Resistance |
3 - 5 | 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2) |
| Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2) |
||
| Ignition Contact Relay (IGCT No. 2)
Resistance |
3 - 5 | 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2) |
| Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2) |
||
| INV Water Pump Relay (INV W/PMP)
Resistance |
3 - 5 | 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2) |
| Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2) |
||
| Battery Fan Relay (BATT FAN)
Resistance |
3 - 5 | 10 kΩ or higher
(Auxiliary battery voltage not applied between terminals 1 and 2) |
| Below 1 Ω
(Auxiliary battery voltage applied between terminals 1 and 2) |
| Item | Tester Connection | Condition | Specified Condition |
| SMRB
Resistance |
N1-1 (CBI) - z13-1 (+) | Auxiliary battery voltage not applied between terminals z24-1 (SMRB) and z24-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals z24-1 (SMRB) and z24-3 (GND) | Below 1 Ω | ||
| z24-1 (SMRB) - z24-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω | |
| SMRG
Resistance |
N2-1 (CEI) - z12-1 (-) | Auxiliary battery voltage not applied between terminals z24-4 (SMRG) and z24-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals z24-4 (SMRG) and z24-3 (GND) | Below 1 Ω | ||
| z24-4 (SMRG) - z24-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω | |
| SMRP
Resistance |
N2-1 (CEI) - z12-1 (-) | Auxiliary battery voltage not applied between terminals z24-2 (SMRP) and z24-3 (GND) | 10 kΩ or higher |
| Auxiliary battery voltage applied between terminals z24-2 (SMRP) and z24-3 (GND) | 24.3 to 29.7 Ω | ||
| z24-2 (SMRP) - z24-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
| No. 1 pattern select switch assembly (DRIVE MODE): | ||
| Tester Connection | Condition | Specified Condition |
| D5-1 (DMS+) - D5-3 (E) | When the DRIVE MODE switch is operated and held on the top side | Below 10 Ω |
| D5-1 (DMS+) - D5-3 (E)
D5-4 (DMS-) - D5-3 (E) |
When the DRIVE MODE switch is not operated | 10 kΩ or higher |
| D5-4 (DMS-) - D5-3 (E) | When the DRIVE MODE switch is operated and held on the bottom side | Below 10 Ω |
| No. 1 pattern select switch assembly (DRIVE MODE): | |
| Measurement Condition | Specified Condition |
| Battery positive (+) → D5-5 (ILL+)
Battery negative (-) → D5-2 (ILL-) |
Illuminates |
| Tester Connection | Condition | Specified Condition |
| Service plug grip | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| EV Battery Terminal Block | Always | Below 1 Ω |