SPECIFICATIONS  FC CONTROL  SERVICE DATA  


HYDROGEN INJECTOR
Tester Connection Condition Specified Condition
1 - 2 21°C (70°F) 1.20 to 1.55Ω

HYDROGEN GAS LEAK (for Medium Pressure)
Measurement Location Specified Value
Connection between Hydrogen Supply Primary Pipe Sub-assembly x Fuel Injector Assembly Less than 500 ppm
Connection between Hydrogen Primary Pressure Sensor x Hydrogen Supply Primary Pipe Sub-assembly
Connection between No. 1 Hydrogen Supply Tube x Hydrogen Supply Primary Pipe Sub-assembly
Connection between No. 1 Hydrogen Supply Tube x No. 2 Hydrogen Supply tube
Connection between No. 1 Hydrogen Supply Tube x No. 2 Hydrogen Supply Tube
Connection between No. 2 Hydrogen Supply Tube Sub-assembly and No. 3 Hydrogen Supply Tube Sub-assembly
Medium Pressure Port of Hydrogen Supply Regulator
Connection between No. 3 Hydrogen Supply Tube Sub-assembly and Hydrogen Supply Regulator

HYDROGEN GAS LEAK (for Low Pressure)
Measurement Location Specified Value
Connection between No. 1 Hydrogen Tube x Hydrogen supply Secondary Pipe Sub-assembly Less than 500 ppm
Connection between Hydrogen Secondary Pressure Sensor x Hydrogen Supply Secondary Pipe Sub-assembly
Connection between Fuel Injector Assembly x Hydrogen Supply Secondary Pipe Sub-assembly
Connection between No. 2 Hydrogen Tube x FC Stack Hydrogen Inlet
Connection between No. 2 Hydrogen Tube x Hydrogen Recirculation Pump Assembly
Connection between Hydrogen Recirculation Pump Assembly x Hydrogen Recirculation Separator Assembly
Connection between No. 1 Hydrogen Tube x FC Stack Hydrogen Inlet
Connection between No. 3 Hydrogen Tube x FC Stack Assembly
Connection between No. 3 Hydrogen Tube x Hydrogen Recirculation Separator Assembly

HYDROGEN RECIRCULATION SEPARATOR
Tester Connection Condition Specified Condition
1 - 2 15 to 25°C 10.5 to 12.5 Ω

INTAKE AIR FLOW METER
Tester Connection Condition Specified Condition
4 (THA) - 2 (E2G) -20°C (-4°F) 13.6 to 18.4 kΩ
20°C (68°F) 2.21 to 2.69 kΩ
60°C (140°F) 0.49 to 0.67 kΩ

WATER TEMPERATURE SENSOR
Tester Connection Condition Specified Condition
1 - 2 Approximately 20°C (68°F) 2.32 to 2.59 kΩ
Approximately 80°C (176°F) 0.310 to 0.326 kΩ

PRESSURE SENSOR
Tester Connection Condition Specified Condition
4 (THA) - 2 (E2) 20°C (68°F) 2.09 to 2.81 kΩ

HYDROGEN PRESSURE SENSOR
Item Tester Connection Condition Specified Condition

*: The output voltage changes depending on the voltage applied to the terminals.

Hydrogen Secondary Pressure Sensor 3(VHPL) - 2(GHPL) IG ON 4.75 to 5.25 V
1(HPL) - 2(GHPL) IG ON 3.0 to 5.25 V
Hydrogen Primary Pressure Sensor 2 (HPM) - 3 (VHPM) Pressure not applied to hydrogen primary pressure sensor Approximately 0.56 to 0.94 V*

FC WATER RELEASE SWITCH
Tester Connection Condition Specified Condition
2 (E) - 3 (SW) Switch on Below 1 Ω
Switch off 10 kΩ or higher
Auxiliary battery positive (+) → 4 (ILL+)
Auxiliary battery negative (-) → 1 (ILL-)
LED illuminates

HYDROGEN DETECTOR (for Motor Room Side) (Check using the GTS)
Hydrogen concentration displayed 0.9 % or more

HYDROGEN DETECTOR (for Motor Room Side) (Check without using the GTS)
Detection Status Specified Condition
Detected (check result is OK)
·

Hazard warning light illuminates (each light turns on 6 times or more for 5 seconds)

·

Wireless buzzer sounds (each buzzer sounds 6 times or more for 5 seconds)


Not detected (check result is NG)
·

Hazard warning light does not illuminate

·

Wireless buzzer does not sound



HYDROGEN DETECTOR (for Hydrogen Tank Side) (Check using the GTS)
Hydrogen concentration displayed 0.9 % or more

HYDROGEN DETECTOR (for Hydrogen Tank Side) (Check without using the GTS)
Detection Status Specified Condition
Detected (check result is OK)
·

Hazard warning light illuminates (each light turns on 6 times or more for 5 seconds)

·

Wireless buzzer sounds (each buzzer sounds 6 times or more for 5 seconds)


Not detected (check result is NG)
·

Hazard warning light does not illuminate

·

Wireless buzzer does not sound



RELAY
Item Tester Connection Condition Specified Condition
Standard Resistance
(FC-B Relay)
3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(No. 2 ignition relay (IG2))
3 - 5 Auxiliary battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Auxiliary battery voltage applied between terminals 1 and 2 Below 1 Ω