Home › Audio / Visual / Telematics › TELEMATICS › TELEMATICS SYSTEM (for TOYOTA Connect) › from 2021.08
RM37H0E _56 Audio / Visual / Telematics _095262 TELEMATICS _0484973 TELEMATICS SYSTEM(for TOYOTA Connect) U

TELEMATICS  TELEMATICS SYSTEM(for TOYOTA Connect)  TERMINALS OF ECU  


TELEMATICS TRANSCEIVER


E418542N36
0.406,0.25 0.823,0.5 0.417,0.25 1.385,0.25 1.802,0.5 0.417,0.25 3.083,0.25 3.5,0.5 0.417,0.25 5.167,0.25 5.583,0.5 0.417,0.25 2.229,0.24 2.646,0.49 0.417,0.25 0.917,0.25 1.333,0.5 0.417,0.25 3.177,0.292 3.573,0.531 0.396,0.24 10 false D72 5.271,0.292 5.698,0.49 0.427,0.198 10 false D68 2.281,0.292 2.677,0.531 0.396,0.24 10 false D138 0.448,0.292 0.896,0.531 0.448,0.24 10 false ANT3 1.438,0.302 1.885,0.542 0.448,0.24 10 false ANT1 0.958,0.281 1.406,0.521 0.448,0.24 10 false ANT2

Terminal No. (Symbol) Terminal Description Condition Specified Condition
D68-1 (+B) - D68-20 (E) Power source (+B) Ignition switch off 11 to 14 V
D68-3 (SIG-) - D68-20 (E) Ground Always Below 1 Ω
D68-4 (IND1) - D68-20 (E) Emergency call switch red indicator illumination signal For 5 seconds after turning the ignition switch turned to ON 2 to 4 V
Ignition switch off Below 1 V
D68-5 (MCVD) - D68-20 (E) Telephone microphone assembly power supply Ignition switch ON 4 to 6 V
Ignition switch off Below 1 V
D68-6 (MCI+) - D68-20 (E) Microphone voice signal Voice being input to telephone microphone assembly A waveform synchronized with microphone voice signal is input
D68-7 (MCI-) - D68-20 (E) Microphone voice signal Always Below 1 V
D68-10 (CNP2) CAN communication signal - -
D68-11 (CNN2) CAN communication signal - -
D68-13 (GSW) - D68-20 (E) Collision detection signal Ignition switch ON Pulse generation (Refer to waveform 1)
D68-14 (MUTE) - D68-20 (E) MUTE Signal Audio system playing 3.5 V or higher
Emergency call mode Below 1 V
D68-15 (USBV) - D68-20 (E) Telematics transceiver power supply signal Ignition switch ON 3 to 6 V
Ignition switch off Below 1 V
D68-16 (MCO+) - D68-20 (E) Microphone voice signal Voice being input to telephone microphone assembly A waveform synchronized with microphone voice signal is input
D68-17 (VOT+) - D68-20 (E) Sent voice signal Calling while using the operator service A waveform synchronized with the received voice is output
D68-18 (VOR+) - D68-20 (E) Receive voice signal Receiving a call while using the operator service A waveform synchronized with the sent voice is output
D68-19 (IG2) - D68-20 (E) Power source (IG) Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
D68-20 (E) - Body ground Ground Always Below 1 Ω
D68-21 (SIG1) - D68-3 (SIG-) Emergency call switch button condition signal Emergency call switch not pressed 1.3 to 1.9 V
Emergency call switch pressed 0.5 to 0.8 V
D68-22 (IND2) - D68-20 (E) Emergency call switch green indicator illumination signal For 5 seconds after turning the ignition switch to ON 2 to 4 V
Ignition switch off Below 1 V
D68-23 (SGND) - D68-20 (E) Shield ground Always Below 1 Ω
D68-25 (CANP) CAN communication signal - -
D68-26 (CANN) CAN communication signal - -
D68-31 (USBG) - Body ground Shield ground Always Below 1 Ω
D68-32 (MCO-) - D68-20 (E) Microphone voice signal Always Below 1 V
D68-33 (VOT-) - D68-20 (E) Sent voice signal Calling while using the operator service A waveform synchronized with the received voice is output
D68-34 (VOR-) - D68-20 (E) Receive voice signal Receiving a call while using the operator service A waveform synchronized with the sent voice is output
D72-1 (SPI+) - D68-20 (E) Sound signal Audio system playing A waveform synchronized with sound signals is output
D72-2 (SPI-) - D68-20 (E) Sound signal Audio system playing A waveform synchronized with sound signals is output
D72-3 (SPO+) - D68-20 (E) Sound signal Audio system playing, or emergency call mode A waveform synchronized with sound signals is output
D72-4 (SPO-) - D68-20 (E) Sound signal Audio system playing, or emergency call mode A waveform synchronized with sound signals is output
D138-1 (USB-) USB communication line - -
D138-2 (USB+) USB communication line - -
D138-3 (USBS) - Body ground Shield ground Always Below 1 Ω

a.

Reference (Oscilloscope waveform):

i.
E165239E01
0.1,2.23 0.491,2.461 0.391,0.230 10 GND

Waveform 1

Item Condition
Tester Connection D68-13 (GSW) - D68-20 (E)
Tool Setting 5.0 V/DIV., 20 ms./DIV.
Vehicle Condition Ignition switch ON