FREEZE FRAME DATA
The EV control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / EV / Trouble Codes.
Select a DTC in order to display its freeze frame data.
Check the freeze frame information recorded with the DTC.
| Tester Display | Measurement Item | Range |
|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
| Maximum Vehicle Speed | Maximum vehicle speed | Min.: 0 km/h (0 mph), Max.: 254 km/h (157 mph) |
| Starter Switch Signal | Starter ON / OFF signal | OFF or ON |
| Engine Start Request (Hybrid/EV Battery Charging) | Engine idling request to charge EV supply battery assembly | OFF or ON |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0.0%, Max.: 100.0% |
| Accelerator Pedal Status | Accelerator Pedal Status | OFF or ON |
| Accelerator Position Sensor No.1 Voltage % | Accelerator pedal position sensor No. 1 | Min.: 0.00%, Max.: 100.00% |
| Accelerator Position Sensor No.2 Voltage % | Accelerator pedal position sensor No. 2 | Min.: 0.00%, Max.: 100.00% |
| Master Cylinder Control Torque | Braking torque equivalent to master cylinder brake fluid pressure
(Total braking torque) |
Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Brake Cancel Switch | Brake pedal status | OFF or ON |
| Shift Position | Current shift state | P / R / N / D / B |
| Shift Position (Meter) | Shift position of meter display | Not Displayed / P / R / N / D / B |
| Shift Switch Status (N,P Position) | Shift position status (N or P position) | ON or OFF |
| Transaxle Oil Temperature | FCV with motor transaxle oil temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Transaxle Oil Temperature Sensor Voltage | Transaxle fluid temperature sensor voltage | Min: 0.00 V, Max: 4.99 V |
| FR Wheel Speed | Front wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| FL Wheel Speed | Front wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| RR Wheel Speed | Rear wheel speed RH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| RL Wheel Speed | Rear wheel speed LH | Min.: 0 km/h (0 mph), Max.: 327.67 km/h (204 mph) |
| Steering Angle Signal | Steering angle signal | Min.: -3276.8 deg, Max.: 3276.7 deg |
| Yaw Rate Value | Yaw rate value | Min.: -128.0 deg/s, Max.: 127.9 deg/s |
| Atmospheric Pressure Sensor Voltage | Atmospheric pressure sensor voltage | Min.: 0.00 V, Max.: 4.99 V |
| Atmospheric Pressure | Atmospheric pressure | Min.: 0 kPa(abs) (0 psi), Max.: 655.35 kPa(abs) (95 psi) |
| Atmospheric Pressure (Filtered Value) | Atmospheric pressure (filtered value) | Min.: 0 kPa(abs) (0 psi), Max.: 655.35 kPa(abs) (95 psi) |
| Atmospheric Pressure (MG) | Atmospheric pressure (MG) | Min.: 0 kPa(abs) (0 psi), Max.: 655.35 kPa(abs) (95 psi) |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Estimate Gradient of Road Surface (Right and Left) | Estimate gradient of road surface (right and left) | Min.: -25.6 deg, Max.: 25.4 deg |
| Ready Lighting Request (Normal Start) | Ready lighting request (normal start) | OFF or ON |
| Freeze Start Rejection | Freeze start rejection | OFF or ON |
| BATT Voltage | Auxiliary battery voltage
(BATT terminal voltage) |
Min.: 0.00 V, Max.: 79.99 V |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage | Min.: 0.00 V, Max.: 65.535 V |
| Total Voltage | Total voltage | Min.: 0.00 V, Max.: 65.535 V |
| Internal Voltage | Internal voltage | Min.: 0.00 V, Max.: 65.535 V |
| Input Power | Input power | Min.: 0.00 kW, Max.: 12.75 kW |
| Internal Power Supply Voltage (VHMR) | Internal power supply voltage (VHMR) | Min.: 0.00 V, Max.: 79.99 V |
| Distance from DTC Cleared | Drive distance after clearing DTCs | Min.: 0, Max.: 65535 |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile |
| MIL ON Run Distance | Drive distance from MIL on | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
| IG Switch (Twice Read) | IG switch (twice read) | OFF or ON |
| IGB Signal Status | IGB signal status | OFF or ON |
| IG2 Signal Status | IG2 signal status | OFF or ON |
| IG2 Controlling Signal Status | IG2 controlling signal status | OFF or ON |
| IGBD Status | IGBD status | OFF or ON |
| IGBD Signal Status | IGBD signal status | OFF or ON |
| IG ON Status | IG ON status | OFF or ON |
| Ready Signal | Ready signal status | OFF or ON |
| HV/EV Activate Condition | Hybrid control system power source mode status | Normal / Remote Air Control System / Remote |
| DSS Control Status | Control status of DSS (Driving Support System) | Not Control / Available / Unavailable / Disable |
| Generate Torque (Request from DSS) | Generated drive torque requested from DSS (Driving Support System) | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Target Propeller Shaft Torque (DSS Last Time Value) | Target propeller shaft torque (DSS last time value) | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Primary Driving Force Adjustment Result | Result of adjustment between drive force of DSS (Driving Support System) and drive force requested by accelerator pedal operation | Accelerator or DSS |
| SMRG Status | Operating state of SMRG
(primary circuit monitor) |
OFF or ON |
| SMRG Control Status | Commanded state of SMRG | OFF or ON |
| SMRB Status | Operating state of SMRB
(primary circuit monitor) |
OFF or ON |
| SMRB Control Status | Commanded state of SMRB | OFF or ON |
| SMRP Status | Operating state of SMRP
(primary circuit monitor) |
OFF or ON |
| SMRP Control Status | Commanded state of SMRP | OFF or ON |
| SMRP Current-Carrying | SMRP current-carrying | Able or Unable |
| WIN Control Limit Power | WIN control limit power | Min.: 327.68 kW, Max.: 327.67 kW |
| WOUT Control Limit Power | WOUT control limit power | Min.: 327.68 kW, Max.: 327.67 kW |
| GL1 GX Sensor Signal | GL1 GX sensor signal | Min.: 13.107 m/s2, Max.: 13.106 m/s2 |
| GL2 GY Sensor Signal | GL2 GY sensor signal | Min.: 13.107 m/s2, Max.: 13.106 m/s2 |
| A/C Consumption Power | A/C consumption power | Min.: 0.00 kW, Max.: 12.75 kW |
| Mode Status | Mode status | Waiting / Driving / Battery Charging / Auxiliary Battery Charging / Battery Diagnosis / Battery Charging (Battery Diagnosis) / Parking Purge / Power Feeding / Remote A/C / SMR Connect / Emergency Power Feeding / Stop |
| Drive Mode Switch- | DRIVE MODE switch (NO. 1 pattern select switch assembly) status | OFF or ON |
| Drive Mode Switch+ | DRIVE MODE switch (NO. 1 pattern select switch assembly) status | OFF or ON |
| Drive Mode Status | Drive mode status | Initial Value / Preparing / Driving / Finish |
| Snow Mode Status | Snow mode status | OFF or ON |
| Snow Mode Switch | SNOW mode switch (pattern select switch assembly) condition | ON or OFF |
| Hybrid/EV Control Current | Hybrid control current | Min.: -3276.8 A, Max.: 3276.7 A |
| Hybrid/EV Control Total Voltage | Hybrid control total voltage | Min.: 0.00 V, Max.: 65.535 V |
| LIN4 Communication Control Permission | LIN4 communication control permission | NG or OK |
| Inter Lock Switch | Interlock switch condition | OFF or ON |
| Stop Light Switch | Stop light switch assembly condition | OFF or ON |
| AC100V Accessory Outlet Switch | Status of power outlet switch | ON or OFF |
| Airbag Status (Collision) | Airbag ECU assembly collision detection | OFF or ON |
| Airbag Status (Collision) (CAN) | Airbag ECU assembly collision detection
(CAN) |
Normal / Collision from Back / Airbag Circuit Abnormal / Safing / Collision from Front or Side |
| Airbag Status (Normal) | Control state of airbag ECU assembly | OFF or ON |
| TC Terminal | TC terminal state | OFF or ON |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Target Motor Torque | Motor (MG2) torque request value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Request Motor Regenerative Brake Torque | Requested motor (MG2) regenerative braking torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Regenerate Brake Execution Torque | Motor (MG2) regenerative braking execution torque | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Temperature | Motor (MG2) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Temperature Sensor Voltage | Motor (MG2) temperature sensor voltage | Min.: 0 V, Max.: 4.99 V |
| Motor Temperature just after IG ON | Motor (MG2) temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Maximum Temperature | Maximum motor (MG2) temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Motor Inverter Temperature | Motor inverter temperature | Min.: 15°C (-59°F), Max.: 150°C (302°F) |
| Motor Inverter Temperature just after IG ON | Motor inverter temperature soon after ignition switch ON | Min.: 15°C (-59°F), Max.: 150°C (302°F) |
| Motor Inverter Maximum Temperature | Maximum motor inverter temperature after ignition switch turned to ON in current trip | Min.: 15°C (-59°F), Max.: 150°C (302°F) |
| Boosting Converter Temperature (Upper) | Boost converter temperature (upper) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Temperature (Lower) | Boost converter temperature (lower) | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Temperature just after IG ON | Boost converter temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Maximum Temperature | Maximum converter temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Boosting Converter Operation Request | Boosting converter operation request | Normal / Boosting Stop / Upper Arm ON / Maximum Boosting / Output Torque / Upper Arm Lowering |
| Motor Carrier Frequency | Motor (MG2) carrier frequency | 0 to 255 |
| Motor Control Mode | Motor (MG2) control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode |
| Boosting Converter Carrier Frequency | Boost converter signal carrier frequency | HI or LO |
| Boosting Converter Gate Shutdown Request | Boosting converter gate shutdown request | OFF or ON |
| Boosting Converter Shutdown Status | Boosting converter shutdown status | Awake or Shutdown |
| Boosting Converter Overcurrent | Boosting converter overcurrent | OFF or ON |
| Boosting Converter Input Overvoltage | Boosting converter input overvoltage | OFF or ON |
| Motor Operation Status | Motor operation status | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive |
| Motor Torque Estimate Value | Motor torque estimate value | Min.: -4096.00 Nm, Max.: 4095.87 Nm |
| Motor Gate Shutdown Request | Motor gate shutdown request | OFF or ON |
| Motor Inverter Shutdown Status | Motor inverter shutdown status | OFF or ON |
| Motor Inverter Overcurrent | Motor inverter overcurrent | OFF or ON |
| VL-Voltage before Boosting | High voltage before it is boosted | - |
| VH-Voltage after Boosting | High voltage after it is boosted | - |
| Boost Ratio | Boost converter boost ratio | Min.: 0.0%, Max.: 100.0% |
| V Phase Motor Current | V phase motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| W Phase Motor Current | W phase motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| DC/DC Converter Stop Request | DC/DC converter stop request | OFF or ON |
| DC/DC Converter Terminal Voltage (Abnormal Detection Signal) | DC/DC converter terminal voltage (abnormal detection signal) | Min.: 0.00 V, Max.: 4.98 V |
| DC/DC Converter Output Voltage Change Signal | DC/DC converter output voltage change signal | Min.: 0.00 V, Max.: 4.98 V |
| DC/DC Converter Output Voltage Change Signal Duty | DC/DC converter output voltage change signal duty | Min.: 0.0%, Max.: 127.5% |
| Inverter Coolant Water Temperature | Inverter coolant temperature | Min.: -40°C (-40°F), Max.: 110°C (230°F) |
| Inverter Water Pump Duty Ratio | Water with motor pump motor driver request duty | Min.: 0.0%, Max.: 100.0% |
| Inverter Water Pump Revolution | Water with motor pump assembly speed | Min.: 0 rpm, Max.: 15000 rpm |
| Inverter Emergency Shutdown (Main CPU) | Inverter emergency shutdown (main CPU) | OFF or ON |
| Inverter Emergency Shutdown (Sub CPU) | Inverter emergency shutdown (sub CPU) | ON or OFF |
| AC Inverter Shutdown Request | AC inverter shutdown request | OFF or ON |
| Inverter Input Overvoltage | Inverter input overvoltage | OFF or ON |
| Inverter Water Pump Drive Request | Water with motor pump drive request | Stop / Super Extra Low / Extra Low / Low / Middle / High |
| AC Inverter Start | AC Inverter Start | Able or Unable |
| AC Inverter Switch Indicator Control Status | AC inverter switch indicator control status | OFF or ON |
| AC Inverter Operation Status | AC inverter operation status | OFF or ON |
| AC Inverter Drive Signal | AC inverter drive signal | OFF or ON |
| AC Inverter Output Voltage | AC inverter output voltage | 0.0 to 4.99 V |
| Target MG Cooling Oil Pump Motor Duty | Oil with motor pump request duty | Min.: 0.0%, Max.: 100.0% |
| MG Cooling Oil Pump Motor Speed | Oil with motor pump motor speed | Min.: 0 rpm, Max.: 65535 rpm |
| MG Cooling Oil Pump Motor Power Relay Request | OIL PMP MTR relay operation request | OFF or ON |
| MG Shutdown Signal Monitor Voltage | MG shutdown signal monitor voltage | 0.0 to 4.98 V |
| Hybrid/EV Battery SOC | EV supply battery state of charge
Primary calculated from charging and discharging amperage |
Min.: 0.00%, Max.: 100.00% |
| Hybrid/EV Battery SOC just after IG ON | EV supply battery state of charge soon after ignition switch ON | Min.: 0.0%, Max.: 127.5% |
| Hybrid/EV Battery Maximum SOC | Maximum SOC after ignition switch turned to ON in current trip | Min.: 0.0%, Max.: 127.5% |
| Hybrid/EV Battery Minimum SOC | Minimum SOC after ignition switch turned to ON in current trip | Min.: 0.0%, Max.: 127.5% |
| Hybrid/EV Battery Voltage | EV supply battery voltage | Min.: 0.00 V, Max.: 510.00 V |
| Hybrid/EV Battery Current | EV supply battery current | Min.: -327.68 A, Max.: 327.67 A |
| Hybrid/EV Battery Current for Driving Control | EV supply battery current for driving control | Min.: -327.68 A, Max.: 327.67 A |
| Hybrid/EV Battery Control Mode | EV supply battery current mode | Driving Control Mode / Current Sensor Offset Calibration Mode / Hybrid/EV Battery External Charging Control Mode / ECU Shutdown Mode |
| Hybrid/EV Battery Cooling Fan Low Speed Request | Battery cooling blower assembly Lo speed requested | OFF or ON |
| Short Wave Highest Value Level | Waveform voltage level in abnormal insulation detection circuit in battery ECU assembly | Not Judge / Normal / Insulation Lower LV2 / Insulation Lower LV3 |
| Insulation Resistance Division Check Completion using MG Inv | Insulation resistance division check completion using MG inv | Not Complete or Complete |
| Insulation Resistance Division Check Completion using A/C Inv | Insulation resistance division check completion using A/C inv | Not Complete or Complete |
| Insulation Resistance Division Check Completion using SMR | Insulation resistance division check completion using SMR | Not Complete or Complete |
| Short Wave Highest Value Availability just after MG Inv On/Off | Short wave highest value availability just after MG inv on/off | Yes or No |
| Short Wave Highest Value Availability just after A/C Inv On/Off | Short wave highest value availability just after A/C inv on/off | Yes or No |
| Short Wave Highest Value Availability just after SMR On/Off | Short wave highest value availability just after SMR on/off | Yes or No |
| Hybrid/EV System Insulation Status | Hybrid system insulation status | Not Judged / Normal / Abnormal / Abnormal (Large) |
| FC Air Compressor Area Insulation Resistance Division Check Completion | FC air compressor area insulation resistance division check completion | Not Complete or Complete |
| FC Coolant Pump Area Insulation Resistance Division Check Completion | FC cooling water pump area insulation resistance division check completion | Not Complete or Complete |
| Hydrogen Pump Area Insulation Resistance Division Check Completion | Hydrogen recirculation pump area insulation resistance division check completion | Not Complete or Complete |
| FC Area Insulation Resistance Division Check Completion | FC area insulation resistance division check completion | Not Complete or Complete |
| Motor Area Insulation Resistance Division Check Completion | Motor area insulation resistance division check completion | Not Complete or Complete |
| A/C Area Insulation Resistance Division Check Completion | A/C area insulation resistance division check completion | Not Complete or Complete |
| Hybrid/EV Battery Area Insulation Resistance Division Check Completion | EV supply battery area insulation resistance division check completion | Not Complete or Complete |
| Insulation Resistance Deterioration Elapsed Time | Insulation resistance deterioration elapsed time | Min.: 0 min, Max.: 65535 min |
| Short Wave Highest Value | Short wave highest value | Min.: 0.00 V, Max.: 4.98 V |
| Immobiliser Communication | Immobiliser communication line status | OFF or ON |
| Permit Start by Immobiliser | Status of starting permission by immobiliser (immobiliser to EV control ECU) | No Judgment / OK / NG |
| Auxiliary Battery Voltage | Auxiliary battery voltage (+B3, +B4 terminals voltage) | Min.: 0.00 V, Max.: 16.00 V |
| Auxiliary Voltage | Auxiliary voltage | Min.: 0.00 V, Max.: 20.00 V |
| Auxiliary Battery Current | Auxiliary battery current | Min.: -125.00 A, Max.: 124.99 A |
| Smoothed Value of Auxiliary Battery Temperature | Smoothed value of auxiliary battery temperature | Min.: -40.0°C (-40.0°F), Max.: 6513.5°C (11756.3°F) |
| Auxiliary Battery Status of Full Charge | Auxiliary battery status when full charge | Min.: 0.00 Ah, Max.: 127.5 Ah |
| Auxiliary Battery Charging Rate Accuracy | Auxiliary battery charging rate accuracy | Low / Middle / High / Disable |
| Auxiliary Battery Power Supply Voltage Low | Auxiliary battery power supply voltage low | OFF or ON |
| FC Work Mode | Mode of the FC stack operation | Stop / Finishing / Startup / Working |
| FC System Status | FC system status | Stop / Finishing / Startup / Working |
| FC Power Generation Status | Mode of the FC stack power generation | Normal / Intermittent / Quick Warmup |
| FC Converter Status | FC boost converter status | Normal or Abnormal |
| FC Converter Shutdown Request | Shut down request to the FC boost control ECU | OFF or ON |
| FC Converter Shutdown Status | FC boost converter shutdown status | OFF or ON |
| FC Converter Shutdown Signal | FC boost converter shutdown signal | OFF or ON |
| FC Air Compressor Gate Shutdown Request | FC air compressor inverter shutdown request | OFF or ON |
| FC Air Compressor Shutdown Status | FC air compressor inverter shutdown status | OFF or ON |
| FC Air Compressor Consumption Power | Measure power consumption of the FC air compressor with motor assembly | Min.: 0 W, Max.: 65535 W |
| FC Air Compressor Temperature just after IG ON | FC air compressor motor temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| FC Air Compressor Maximum Temperature | Maximum FC air compressor motor temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| FC Air Compressor Motor Operation Status | FC air compressor motor operation status | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive |
| FC Air Compressor Motor Control Mode | FC air compressor motor control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode |
| V Phase FC Air Compressor Motor Current | V phase FC air compressor motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| W Phase FC Air Compressor Motor Current | W phase FC air compressor motor current | Min.: -3276.8 A, Max.: 3276.7 A |
| FC Air Compressor Motor Carrier Frequency | FC air compressor motor carrier frequency | 0 to 255 |
| FC Air Compressor Motor Temperature | FC air compressor motor temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| FC Air Compressor Motor Temperature (Filtered Value) | FC air compressor motor temperature filtered value | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| FC Air Compressor Motor Torque Estimate Value | FC air compressor motor torque estimate value | Min.: -4096 Nm, Max.: 4095.87 Nm |
| FC Air Compressor Inverter Shutdown Status | FC air compressor inverter shutdown | OFF or ON |
| FC Air Compressor Inverter Stop | FC air compressor inverter stopped | OFF or ON |
| FC Air Compressor Inverter Maximum Temperature | Maximum FC air compressor inverter temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| FC Air Compressor Inverter Overcurrent | Overcurrent detection into FC air compressor inverter | OFF or OM |
| FC Air Compressor Inverter Temperature | FC air compressor inverter temperature | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) |
| FC Air Compressor Inverter Temperature (Filtered Value) | FC air compressor inverter temperature filtered value | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) |
| FC Air Compressor Inverter Temperature just after IG ON | FC air compressor inverter temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) |
| FCDC Input Voltage | FC boost converter (FC converter power module transistor) input voltage sensor value | Min.: 0 V, Max.: 6553.5 V |
| FCDC Output Voltage | FC boost converter (FC converter power module transistor) output voltage sensor value | Min.: 0 V, Max.: 6553.5 V |
| Power Feeding Electrical Using Status | Usage state of power supplied from external power source charging | Charge Sustaining Mode / Not PHV / Charge Depleting Mode / Charge Increasing Mode / Ready OFF |