Data List (EV)
Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.
Data List relating to hydrogen filling
While the hydrogen tank is filled, turning the ignition switch to ON allows a GTS to access the Data List for the hydrogen filling. When accessing, communication error DTCs could be output. If this happens, clear such DTCs.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / EV / Data List.
Check the results by referring to the following table.
For hybrid (EV) control items, refer to Hybrid Control System.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DATA LIST / ACTIVE TEST
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | Vehicle stopped:
0 km/h (0 mph) While driving at a constant speed: No significant fluctuation |
- |
| Accelerator Position | Accelerator pedal depressed angle | Min.: 0%, Max.: 125.7% | Accelerator pedal depressed:
Changes with accelerator pedal pressure |
- |
| Shift Position | Shift position | P/R/N/D/B | Matches currently selected shift position:
P, R, N, D or B |
- |
| Atmospheric Pressure Sensor Voltage | Output voltage of the barometric pressure sensor | Min.: 0 V, Max.: 4.99 V | - | If the "Atmospheric Pressure Sensor Voltage" is more than 4.70 V or less than 0.30 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Atmospheric Pressure | Atmospheric pressure | Min.: 0 kPa, Max.: 655.35 kPa | - | ·
Standard atmospheric pressure is approximately 101 kPa (15 psi). ·
For every 100 m (328 ft.) increase in altitude, atmospheric pressure drops by approximately 1 kPa (0.1 psi). This varies by weather. ·
Barometric pressure sensor value is built into the EV control ECU. |
| Atmospheric Pressure (Filtered Value) | Atmospheric pressure filtered value | Min.: 0 kPa, Max.: 655.35 kPa | - | - |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Ignition switch ON:
Same as ambient air temperature |
- |
| Intake Air Temperature Sensor Voltage | Output voltage of the intake air temperature sensor | Min.: 0 V, Max.: 4.99 V | - | If the "Intake Air Temperature Sensor Voltage" is more than 4.90 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Intake Air Temperature (Filtered Value) | Intake air temperature filtered value | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Mass Air Flow Sensor Frequency | Output frequency of the mass air flow meter sub-assembly | Min.: 0 kHz, Max.: 12.75 kHz | - | - |
| Target Mass Air Flow | Target supply air volume to the FC stack | Min.: 0 L/min, Max.: 39999.38 L/min | - | - |
| Mass Air Flow (Filtered Value) | Airflow rate from mass air flow meter sub-assembly | Min.: 0 L/min, Max.: 39999.38 L/min | - | - |
| Estimate Gradient of Road Surface (Right and Left) | Tilt angle in the lateral (left-right) direction of the vehicle | Min.: -25.6 deg, Max.: 25.4 deg | 0 deg:
Vehicle stopped on a flat surface with no tilt |
Leaving the vehicle in READY ON state for a long time in a location with a large left-right tilt may result in FC power generation stop due to poor drainage. |
| Ready Lighting Request (Normal Start) | READY lighting request status during normal start | ON/OFF | ON: Ignition switch ON (READY) | - |
| Freeze Start Rejection | FC system could not start up due to freezing | ON/OFF | - | - |
| BATT Voltage | BATT voltage | Min.: 0 V, Max.: 79.99 V | - | BATT terminal voltage of the EV control ECU. |
| Total Voltage | FC stack power generation voltage calculated from the cell monitor (Total amount of each cell voltages) | Min.: 0 V, Max.: 3553.5 V | 0 to 330.0 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| Internal Voltage | Power supply voltage applied from the FC-B relay | Min.: 0 V, Max.: 3553.5 V | 11.00 to 14.70 V:
Ignition switch ON |
This is the power supply voltage that is used to actuate the following valves:
Air sealing valve, air shunt valve, air pressure regulating valve, exhaust drainage valve, FC cooling water temperature control valve. |
| Input Power | A/C consumption power | Min.: 0 kW, Max.: 12.75 kW | 0 to 5.00 kW:
While the air conditioning system is operating |
- |
| Internal Power Supply Voltage (VHMR) | Power source voltage of the hydrogen detector (for front compartment side) | Min.: 0 V, Max.: 79.99 V | 0 to 5.1 V | - |
| Total Distance Traveled | Drive total distance | Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) | - | - |
| Total Distance Traveled - Unit | Unit of drive total distance | km/mile | - | - |
| IG2 Signal Status | IG2 signal status | ON/OFF | ON: Ignition switch ON | - |
| Ready Signal | State of system (READY) | ON/OFF | ON: Ignition switch ON (READY) | - |
| HV/EV Activate Condition | Indicates the EV start condition | Normal/Remote Air Control System/Remote | - | - |
| Fuel Lid Interlock Switch | Fuel lid interlock switch condition | ON/OFF | ON:
Fuel lid open OFF: Fuel lid fully closed |
The interlock switch is used to prevent the vehicle from running while the hydrogen filling nozzle is connected to the vehicle. Thus, the interlock switch monitors if the fuel lid is open or closed. |
| Fuel Lid Open Switch | Fuel lid opener switch | ON/OFF | ON:
Fuel lid opener switch pressed |
- |
| FC Precharge Relay Drive Request | Actuation requests of the FC relay precharge side (FRP) | ON/OFF | - | - |
| FC Negative Relay Drive Request | Actuation requests of the FC relay negative side (FRG) | ON/OFF | - | - |
| FC Positive Relay Drive Request | Actuation requests of the FC relay positive side (FRB) | ON/OFF | - | - |
| Radiator Rotary Valve Drive Position | Operation opening angle of the FC cooling water temperature control valve | Min.: 0%, Max.: 255% | - | 0%:
FC stack → Radiator passage is closed 100.00%: FC stack → Radiator passage is opened |
| Target Radiator Rotary Valve Position | Target opening angle of the FC cooling water temperature control valve | Min.: 0%, Max.: 399.99% | - | 0%:
FC stack → Radiator passage is closed 100.00%: FC stack → Radiator passage is opened |
| Radiator Rotary Valve Position | Anticipated current opening angle of the FC cooling water temperature control valve | Min.: 0%, Max.: 399.99% | - | 0%:
FC stack → Radiator passage is closed 100.00%: FC stack → Radiator passage is opened |
| Air Pressure Regulating Valve Drive Position | Operation opening angle of the air pressure regulating valve | Min.: 0%, Max.: 255% | - | - |
| Air Shunt Valve Drive Position | Operation opening angle of the air shunt valve | Min.: 0%, Max.: 255% | - | - |
| Air Sealing Valve Drive Position | Operation opening angle of the air sealing valve | Min.: 0%, Max.: 255% | - | - |
| Tank Shut Valve 1 Drive Status | Actuation requests to the tank shut valve of the No. 1 hydrogen tank assembly | Open/Close | Open:
Ignition switch ON (READY) Close: READY off |
Requests are off during hydrogen leak inspection of vehicle control. |
| Tank Shut Valve 1 Status | Tank shut valve actuation circuit condition of the No. 1 hydrogen tank assembly | Open/Close | Open:
Ignition switch ON (READY) Close: READY off |
- |
| Tank Shut Valve 2 Drive Status | Actuation requests to the tank shut valve of the No. 2 hydrogen tank assembly | Open/Close | Open:
Ignition switch ON (READY) Close: READY off |
Requests are off during hydrogen leak inspection of vehicle control. |
| Tank Shut Valve 2 Status | Tank shut valve actuation circuit condition of the No. 2 hydrogen tank assembly | Open/Close | Open:
Ignition switch ON (READY) Close: READY off |
- |
| Tank Shut Valve 3 Drive Status | Actuation requests to the tank shut valve of the No. 3 hydrogen tank assembly | Open/Close | Open:
Ignition switch ON (READY) Close: READY off |
Requests are off during hydrogen leak inspection of vehicle control. |
| Tank Shut Valve 3 Status | Tank shut valve actuation circuit condition of the No. 3 hydrogen tank assembly | Open/Close | Open:
Ignition switch ON (READY) Close: READY off |
- |
| Tank Shut Valve Power Relay Drive Status | H2 SHUT VLV relay actuation circuit condition | ON/OFF | ON:
Ignition switch ON OFF: Ignition switch off |
- |
| Tank Shut Valve Power Relay Drive Signal Status | Actuation requests to the H2 SHUT VLV relay | ON/OFF | ON:
Ignition switch ON OFF: Ignition switch off |
The EV control ECU switches the H2 SHUT VLV relay on or off. |
| Hydrogen Pump Drive Speed | Drive speed of the hydrogen pump | Min.: 0 rpm, Max.: 65535 rpm | - | - |
| Hydrogen Pump Speed | Measured motor speed of the hydrogen pump | Min.: -8192 rpm, Max.: 8191.75 rpm | 500.00 to 700.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working) |
- |
| Target Hydrogen Pump Speed | Target motor speed of the hydrogen pump | Min.: -8192 rpm, Max.: 8191.75 rpm | - | - |
| FC Coolant Pump Drive Speed | Drive speed of the FC cooling water pump assembly | Min.: 0 rpm, Max.: 65535 rpm | - | - |
| FC Coolant Pump Speed | Measured motor speed of the FC cooling water pump assembly | Min.: 0 rpm, Max.: 65535 rpm | 0 to 1000.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working) |
Compare a displayed value with the "Target FC Coolant Pump Speed" value. |
| Target FC Coolant Pump Speed | Target motor speed of the FC cooling water pump assembly | Min.: 0 rpm, Max.: 65535 rpm | - | - |
| Radiator Fan 1 Drive Voltage | Requested voltage to the cooling fan controller with motor | Min.: 0 V, Max.: 25.5 V | 0 V:
Cooling fan stopped |
- |
| FC Air Compressor Motor Drive Speed | Drive speed of the FC air compressor with motor assembly | Min.: 0 rpm, Max.: 65535 rpm | - | - |
| FC Air Compressor Motor Speed | Motor speed of the FC air compressor with motor assembly | Min.: -32768 rpm, Max.: 32767 rpm | - | - |
| FC Air Compressor Motor Speed (Measured Value) | Measured motor speed of the FC air compressor with motor assembly | Min.: 0 rpm, Max.: 65535 rpm | 0 to 1000.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| Target FC Air Compressor Motor Speed | Target motor speed of the FC air compressor with motor assembly | Min.: -32768 rpm, Max.: 32767 rpm | - | - |
| Starting Status (An Side) | Starting status (anode side) | Initial State / DC/DC Preparing / Pressurization Preparing / Stack Pressurization / Leak Check/Hydrogen Substitution / Complete | - | For checking changes in status of the FC system starting at ambient temperatures |
| Stopping Status (An Side) | Stopping status (anode side) | Initial State / Pressurization / Drainage / Gas-Liquid Separator Drainage / Partial Pressure/Decompression / Leak Check / Sensor Learning / Isolation Fault Parts Detection / Stopping / Complete | - | For checking changes in status of the FC system stopping at ambient temperatures |
| Starting Status (Ca Side) | Starting status (cathode side) | Initial State / DC/DC Preparing / An Side Preparing / EV Standby / Generation / Diluted State / Complete | - | For checking changes in status of the FC system starting at ambient temperatures |
| Stopping Status (Ca Side) | Stopping status (cathode side) | Initial State / Drainage / Sealing / Oxygen Consumption / Dilution / Isolation Fault Parts Detection / Stopping / Complete | - | For checking changes in status of the FC system stopping at ambient temperatures |
| Restart Execute Time | Time elapsed after turning ignition switch off while driving and then restarting while still driving | Min.: 0 ms, Max.: 65535 ms | - | - |
| Emergency Shutdown Signal (FC) | FCSD terminal status of the EV control ECU | ON/OFF | OFF:
Ignition switch ON (READY) |
- |
| FC Emergency Shutdown Signal | Shut down signal to the FC control ECU | ON/OFF | OFF:
Ignition switch ON (READY) |
- |
| FC Start Request | Displays the FC system start command status | ON/OFF | - | - |
| FC Stop Request | Displays the FC system stop command status | None / Normal Stop / Sudden Stop / Emergency Stop | - | - |
| Master Warning Lighting Request (FC) | Master warning light illumination request signal from the FC control ECU | ON/OFF | OFF:
Ignition switch ON (READY) |
- |
| FC Work Mode | Mode of the FC stack operation | Stop / Finishing / Startup / Working | Stop:
Ignition switch ON |
Stop
·
FC stack has stopped operating ·
The vehicle is in READY OFF mode Startup ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied), which are located after the tank shut valve, are pressurized by supplying compressed hydrogen gas from the hydrogen tank assembly. During pressurization, high-range and low-range hydrogen pressures are monitored. Working ·
FC stack is ready to generate power. Finishing ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied) is depressurized. During depressurization, the high-range and mid-range pressures in the hydrogen supply system are monitored. |
| FC System Status | FC system status | Stop / Finishing / Startup / Working | Stop:
Ignition switch ON |
Stop
·
FC stack has stopped operating ·
The vehicle is in READY OFF mode Startup ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied), which are located after the tank shut valve, are pressurized by supplying compressed hydrogen gas from the hydrogen tank assembly. During pressurization, high-range and low-range hydrogen pressures are monitored. Working ·
FC stack is ready to generate power. Finishing ·
The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied) is depressurized. During depressurization, the high-range and mid-range pressures in the hydrogen supply system are monitored. |
| FC Power Generation Status | Mode of the FC stack power generation | Normal / Intermittent / Quick Warmup | Normal:
Normal FC system control (including FC shutdown) Intermittent: FC intermittent operation Quick Warmup: FC stack quick warmup |
- |
| Target FC Current (Filtered Value) | Command value of the FC stack power generation current | Min.: 0 A, Max.: 655.35 A | - | - |
| FC Current | Measured power generation current of the FC stack | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 50.00 A:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working), A/C off, Electrical load off |
- |
| FC Current (Filtered Value) | Filtered value of the FC stack power generation current | Min.: 0 A, Max.: 655.35 A | - | - |
| Maximum Available FC Current | Maximum possible power generation current value of the FC stack | Min.: 0 A, Max.: 655.35 A | - | - |
| FC Current Limit Value (Temperature High) | FC stack power generation current limit value at high temperatures | Min.: 0 A, Max.: 655.35 A | - | - |
| FC Current Limit Value (Hydrogen Stoichiometric Ratio) | FC stack power generation current limit value due to hydrogen concentration | Min.: 0 A, Max.: 655.35 A | - | - |
| FC Current Limit Value (Auxiliary Battery Driving) | FC stack power generation current limit value due to auxiliary driving | Min.: 0 A, Max.: 655.35 A | - | - |
| FC Current Limit Value (Cell Monitor) | FC stack power generation current limit value according to the cell monitor | Min.: 0 A, Max.: 655.35 A | - | - |
| FC Voltage (Filtered Value) | Measured power generation voltage filtered value of the FC stack | Min.: 0 V, Max.: 655.35 V | 0 V:
Ignition switch ON 0 to 330.0 V: Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| FC Output Power Limit Value (FC Air Compressor Shutdown) | FC stack output limit value due to FC air compressor shutdown | Min.: -327.68 kW, Max.: 327.67 kW | Output is limited due to FC air compressor shutdown: 0 kW | - |
| FC Output Power Limit Value (Hydrogen Gas Level Low) | FC stack output limit value due to low hydrogen level | Min.: -327.68 kW, Max.: 327.67 kW | Output is limited due to low hydrogen level: 0.5 kW or less | - |
| FC Output Power Limit Value (FC Intermittent Operation by Hydrogen Leak) | FC stack output limit value during FC intermittent operation due to hydrogen leak | Min.: -327.68 kW, Max.: 327.67 kW | Output is limited during FC intermittent operation due to hydrogen leak: 0 kW | - |
| FC Intermittent Operation | FC stack power generation waiting state (including very small power generation) | ON/OFF | ON:
FC intermittent operation |
- |
| Target FC Temperature | Target temperature of the FC stack | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | - | - |
| Target FC Inlet Air Pressure | Target air pressure of the FC stack inlet | Min.: 0 kPa, Max.: 1441.77 kPa | - | - |
| FC Inlet Air Pressure (Filtered Value) | Intake air pressure filtered value of the FC stack inlet | Min.: 0 kPa, Max.: 1441.77 kPa | Approximately 100.00 kPa(abs):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| FC Inlet Air Temperature (Filtered Value) | Intake air temperature filtered value of the FC stack inlet | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | Approximately a range of a "Intake Air Temperature (Filtered Value)" to a "Intake Air Temperature (Filtered Value)" plus 20°C (68°F):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| FC Coolant Pump Initial Request | FC cooling water pump inverter assembly initial request | ON/OFF | - | - |
| FC Coolant Pump Main Power Supply Status | FC cooling water pump inverter assembly main power supply status | Normal / Low Voltage / Overvoltage / Abnormal | Normal:
Ignition switch ON (READY) |
- |
| FC Coolant Pump Output Status | FC cooling water pump inverter assembly output status | Normal / Circuit Short / Circuit Open / Current Abnormal | Normal:
Ignition switch ON (READY) |
- |
| FC Coolant Pump Load Status | FC cooling water pump inverter assembly load status | Normal / Inverter Output Voltage Saturation / Motor Current Limit / Soft Overcurrent / Input Overcurrent / Input Current Saturation | Normal:
Ignition switch ON (READY) |
- |
| FC Coolant Pump Over Temperature Status | FC cooling water pump assembly overheating status | Normal / Temperature Limit / Over Temperature / Thermistor Abnormal | Normal:
Ignition switch ON (READY) |
- |
| FC Coolant Pump STB Control Signal | FC cooling water pump inverter assembly standby request signal | ON/OFF | - | Standby request signal from the EV control ECU |
| FC Coolant Pump Inverter STB Status | FC cooling water pump inverter assembly standby signal status | ON/OFF | - | - |
| FC Coolant Pump LIN Communication Control | FC cooling water pump inverter assembly LIN communication control | ON/OFF | - | - |
| FC Coolant Pump Isolation Fault Detection Control | FC cooling water pump inverter assembly current leakage detection control | ON/OFF | - | - |
| Lost Communication with FC Coolant Pump | Communication error with the FC cooling water pump inverter assembly | ON/OFF | - | - |
| FC Coolant Pump CPU Abnormal | FC cooling water pump inverter assembly CPU malfunction | ON/OFF | - | - |
| FC Coolant Pump Start Fail | FC cooling water pump inverter assembly start failure | ON/OFF | - | - |
| FC Coolant Pump Consumption Power | Measured power consumption of the FC cooling water pump assembly | Min.: 0 W, Max.: 65535 W | 100 W or less:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working) |
The FC cooling water pump assembly power consumption increases in proportion to increases in the load of the pump. |
| FC Converter Status | FC boost converter status | Normal/Abnormal | Normal:
Ignition switch ON (READY) |
- |
| FC Converter Shutdown Request | Shut down request to the FC boost control ECU | ON/OFF | - | - |
| FC Converter Shutdown Status | FC boost converter shutdown status | ON/OFF | - | - |
| FC Converter Shutdown Signal | FC boost converter shutdown signal | ON/OFF | - | - |
| FC Air Compressor Gate Shutdown Request | FC air compressor inverter shutdown request | ON/OFF | ON:
FC air compressor inverter shutdown request OFF: Normal |
- |
| FC Air Compressor Shutdown Status | FC air compressor inverter shutdown status | ON/OFF | ON:
FC air compressor inverter shutdown OFF: Normal |
- |
| FC Air Compressor Consumption Power | Measure power consumption of the FC air compressor with motor assembly | Min.: 0 W, Max.: 65535 W | - | Measured power consumption of the FC air compressor with motor assembly |
| FC Air Compressor Temperature just after IG ON | FC air compressor motor temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Air Compressor Maximum Temperature | Maximum FC air compressor motor temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Air Compressor Motor Operation Status | FC air compressor motor operation status | Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive | - | - |
| FC Air Compressor Motor Control Mode | FC air compressor motor control mode | Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode | - | - |
| V Phase FC Air Compressor Motor Current | FC air compressor motor phase V current value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| W Phase FC Air Compressor Motor Current | FC air compressor motor phase W current value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| FC Air Compressor Motor Carrier Frequency | FC air compressor motor carrier frequency | 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode | - | - |
| FC Air Compressor Motor Temperature | FC air compressor motor temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | 25°C (77°F):
Vehicle left for 1 day at an ambient temperature of 25°C (77°F) 25 to 120°C (77 to 248°F): While driving at an ambient temperature of 25°C (77°F) |
AMT terminal signal |
| FC Air Compressor Motor Temperature (Filtered Value) | FC air compressor motor temperature filtered value | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | - | - |
| FC Air Compressor Motor Torque Estimate Value | FC air compressor motor torque estimate value | Min.: -4096 Nm, Max.: 4095.87 Nm | - | - |
| FC Air Compressor Inverter Shutdown Status | FC air compressor inverter shutdown | ON/OFF | ON:
FC air compressor inverter shutdown OFF: Normal |
- |
| FC Air Compressor Inverter Stop | FC air compressor inverter stopped | ON/OFF | ON:
FC air compressor inverter stopped OFF: Normal |
- |
| FC Air Compressor Inverter Maximum Temperature | Maximum FC air compressor inverter temperature after ignition switch turned to ON in current trip | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Air Compressor Inverter Overcurrent | Overcurrent detection into FC air compressor inverter | ON/OFF | ON:
Overcurrent is detected into FC air compressor inverter OFF: Normal |
- |
| FC Air Compressor Inverter Temperature | FC air compressor inverter temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | 15 to 35°C (59 to 95°F):
Vehicle left for 1 day at an ambient temperature of 25°C (77°F) 25 to 120°C (77 to 248°F): While driving at an ambient temperature of 25°C (77°F) |
- |
| FC Air Compressor Inverter Temperature (Filtered Value) | FC air compressor inverter temperature filtered value | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | - | - |
| FC Air Compressor Inverter Temperature just after IG ON | FC air compressor inverter temperature soon after ignition switch ON | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| FC Stack Cell Average Minimum Voltage | Lowest average voltage that is obtained by measuring 2 cell channels among the FC stack 330 cells | Min.: -40 V, Max.: 39.99 V | 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated)) |
- |
| FC Stack Cell Minimum Voltage | Lowest voltage that is obtained by measuring 1 cell channels among the FC stack 330 cells | Min.: -40 V, Max.: 39.99 V | 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated)) |
- |
| Estimate FC Stack Cell Minimum Voltage 1 | Lowest estimate voltage that is obtained by measuring 1 cell channels among the FC stack 330 cells | Min.: -40 V, Max.: 39.99 V | 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated)) |
- |
| Estimate FC Stack Cell Minimum Voltage 2 | Lowest estimate voltage that is obtained by measuring 2 cell channels among the FC stack 330 cells | Min.: -40 V, Max.: 39.99 V | 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated)) |
- |
| FC Stack Cell Average Minimum Voltage ch | Channel number of the lowest average voltage of measured 2 cell channels among the FC stack 330 cells | Min.: 0 ch, Max.: 65535 ch | - | - |
| FC Stack Cell Minimum Voltage ch | Channel number of the lowest voltage of measured 1 cell channels among the FC stack 330 cells | Min.: 0 ch, Max.: 65535 ch | - | - |
| FC Stack Outlet Coolant Temperature Sensor Voltage | Output voltage of the coolant temperature sensor of the FC stack outlet | Min.: 0 V, Max.: 4.99 V | - | If the "FC Stack Outlet Coolant Temperature Sensor Voltage" is more than 4.90 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit. |
| FC Stack Outlet Coolant Temperature (Filtered Value) | Coolant temperature of the FC stack outlet | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | 50°C (122°F) to 85°C (185°F):
After warming up |
- |
| FC Stack Impedance | Impedance (resistance) of the FC stack | Min.: 0 ohm, Max.: 65.535 ohm | Approximately from 0.05 to 0.30 ohm:
Vehicle stationary with ignition switch ON (READY) |
- |
| Maximum Impedance ch | FC stack maximum impedance (resistance) channel number | Min.: 0 ch, Max.: 255 ch | - | - |
| Maximum Impedance Norm | Maximum impedance (resistance) measured at the FC stack channel | Min.: 0 mohm, Max.: 927.77 mohm | - | - |
| Impedance Update Counter | FC stack impedance (resistance) update time | Min.: 0 ms, Max.: 25500 ms | - | - |
| FC Water Release Switch | FC water release switch condition | ON/OFF | ON:
FC water release switch being pushed and held |
- |
| FC Precharge Relay Request | FC relay precharge side (FRP) activation request status | ON/OFF | - | - |
| FC Negative Relay Request | FC relay negative side (FRG) activation request status | ON/OFF | - | - |
| FC Positive Relay Request | FC relay positive side (FRB) activation request status | ON/OFF | - | - |
| FC Precharge Relay Control Status | FC relay precharge side (FRP) request status | ON/OFF | - | - |
| FC Precharge Relay Status | FC relay precharge side (FRP) operation status | ON/OFF | - | - |
| FC Positive Relay Drive Signal Voltage | FC relay positive side (FRB) drive signal voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| FC Positive Relay Drive Status | FC relay positive side (FRB) operation status | Shutdown / Inrush / Keep | - | - |
| FC Negative Relay Drive Signal Voltage | FC relay negative side (FRG) drive signal voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| FC Negative Relay Drive Status | FC relay negative side (FRG) operation status | Shutdown / Inrush / Keep | - | - |
| FC Interlock Switch | FC interlock switch condition | ON/OFF | ON: The FC converter power outlet cable connector connected to the FC converter assembly is disconnected when the ignition switch is turned to ON | - |
| FC Inter Cooler Outlet Temperature Sensor Voltage | Output voltage of the FC stack inlet air temperature sensor | Min.: 0 V, Max.: 4.99 V | - | - |
| FC Inter Cooler Outlet Temperature | FC stack inlet air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | Approximately a range of a "Intake Air Temperature (Filtered Value)" to a "Intake Air Temperature (Filtered Value)" plus 20°C (68°F):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| FC Inter Cooler Outlet Pressure Sensor Voltage | Output voltage of the FC stack inlet air temperature sensor | Min.: 0 V, Max.: 4.99 V | - | - |
| FC Inter Cooler Outlet Pressure | FC stack inlet air pressure | Min.: -327.68 kPa, Max.: 327.57 kPa | Approximately 100.00 kPa(abs):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| Hydrogen Filling (FC) | Hydrogen filling status | ON/OFF | ON: Hydrogen filling | - |
| Hydrogen Filling Control Module Power Supply Relay Drive Signal | HF-B relay actuation signal | ON/OFF | ON: Ignition switch ON | - |
| Target Air Pressure Regulating Valve Position | Target opening angle of the air pressure regulating valve | Min.: -250%, Max.: 249.99% | - | - |
| Air Pressure Regulating Valve Position | Air pressure regulating valve position | Min.: -250%, Max.: 249.99% | - | - |
| Target Air Shunt Valve Position | Target opening angle of the air shunt valve | Min.: -250%, Max.: 249.99% | - | - |
| Air Shunt Valve Position | Air shunt valve position | Min.: -250%, Max.: 249.99% | - | - |
| Target Air Sealing Valve Position | Target opening angle of the air sealing valve | Min.: -250%, Max.: 249.99% | - | - |
| Air Sealing Valve Position | Air sealing valve position | Min.: -250%, Max.: 249.99% | - | - |
| Hydrogen Pump Initial Request | FC hydrogen pump inverter assembly initial request | ON/OFF | - | - |
| Hydrogen Pump Main Power Supply Status | FC hydrogen pump inverter assembly main power supply status | Normal / Low Voltage / Overvoltage / Abnormal | - | - |
| Hydrogen Pump Output Status | FC hydrogen pump inverter assembly output status | Normal / Circuit Short / Circuit Open / Current Abnormal | - | - |
| Hydrogen Pump Load Status | FC hydrogen pump inverter assembly load status | Normal / Inverter Output Voltage Saturation / Motor Current Limit / Input Overcurrent / Input Current Saturation | - | - |
| Hydrogen Pump Inverter STB Status | FC hydrogen pump inverter assembly standby signal status | ON/OFF | - | - |
| Hydrogen Pump LIN Communication Control | FC hydrogen pump inverter assembly LIN communication control | ON/OFF | - | - |
| Hydrogen Pump Isolation Fault Detection Control | FC hydrogen pump inverter assembly current leakage detection control | ON/OFF | - | - |
| Hydrogen Pump CPU Abnormal | FC hydrogen pump inverter assembly CPU malfunction | ON/OFF | - | - |
| Hydrogen Pump Start Fail | FC hydrogen pump inverter assembly start failure | ON/OFF | - | - |
| Hydrogen Pump Inverter Over Temperature Status | FC hydrogen pump inverter assembly overheating status | Normal / Temperature Limit / Over Temperature / Thermistor Abnormal | - | - |
| Hydrogen Pump STB Control Signal | FC hydrogen pump inverter assembly standby request signal | ON/OFF | - | Standby request signal from the EV control ECU |
| Hydrogen Pump Motor Temperature Sensor Voltage | Output voltage of the hydrogen pump motor temperature sensor | Min.: 0 V, Max.: 4.99 V | - | If the "Hydrogen Pump Motor Temperature Sensor Voltage" is more than 4.95 V or less than 0.05 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Hydrogen Pump Motor Temperature (Filtered Value) | Hydrogen pump motor measured temperature filtered value | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | A range of from an ambient temperature to an ambient temperature plus 40°C (104°F):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| Hydrogen Injector Injection Number | The number of fuel injector assemblies that have to operate | Min.: 0, Max.: 255 | - | - |
| Hydrogen Injector 1 Injection Period | Injection period of the No. 1 fuel injector assembly | Min.: 0 μs, Max.: 65535 μs | - | - |
| Hydrogen Injector 2 Injection Period | Injection period of the No. 2 fuel injector assembly | Min.: 0 μs, Max.: 65535 μs | - | - |
| Hydrogen Injector 3 Injection Period | Injection period of the No. 3 fuel injector assembly | Min.: 0 μs, Max.: 65535 μs | - | - |
| Hydrogen Intake Pressure Sensor Voltage | Output voltage of the hydrogen tank pressure sensor (for inlet side) | Min.: 0 V, Max.: 4.99 V | - | If the "Hydrogen Intake Pressure Sensor Voltage" is more than 4.95 V or less than 0.55 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Hydrogen Intake Pressure Sensor Value | Pressure of the hydrogen tank pressure sensor (for inlet side) | Min.: -200 MPa, Max.: 199.99 MPa | Hydrogen filling value:
Varying depending on the filling. Check valve is provided. Filling pressure varies when the lines (pipes) are pressurized by filling hydrogen gas. |
While filling hydrogen, variations in the filling pressure can be checked when the ignition switch is turned to ON |
| Target Low-Range Hydrogen Pressure | Target pressures in the low-range hydrogen pressure system components | Min.: -720.896 kPa, Max.: 720.874 kPa | 110 to 280 kPa(abs):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| High-Range Hydrogen Pressure (Filtered Value) | Internal pressure filtered values of the high-range hydrogen pressure system components | Min.: 0 kPa, Max.: 655350 kPa | 1000 to 87500 kPa(abs):
Vehicle stationary with ignition switch ON (READY) |
This represents a pressure between the tank shut valve and the hydrogen supply regulator assembly |
| Medium-Range Hydrogen Pressure (Filtered Value) | Internal pressure filtered values of the medium-range hydrogen pressure system components | Min.: 0 kPa, Max.: 65535 kPa | 1000 to 1600 kPa(abs):
Vehicle stationary with ignition switch ON (READY) |
- |
| Low-Range Hydrogen Pressure (Filtered Value) | Internal pressure filtered values of the low-range hydrogen pressure system components | Min.: -720.896 kPa, Max.: 720.874 kPa | "Atmospheric pressure plus 10 kPa" to "280 kPa(abs)":
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| Hydrogen Detector (Motor Room) Frequency | Output frequency of the hydrogen detector (for front compartment side) | Min.: 0 kHz, Max.: 65.535 kHz | - | Hydrogen detector output frequency is less than 0.75 kHz, it is suspected that an open or short has occurred in the sensor circuit. |
| Motor Room Hydrogen Density | Hydrogen concentration detected by the hydrogen detector (for front compartment side) | Min.: 0%, Max.: 399.99% | 0.10% or less:
Vehicle stationary with ignition switch ON (READY) |
- |
| Hydrogen Detector 1 Frequency | Output frequency of the hydrogen detector (for hydrogen tank 1, 2 side) | Min.: 0 kHz, Max.: 65.535 kHz | - | Hydrogen detector output frequency is less than 0.75 kHz, it is suspected that an open or short has occurred in the sensor circuit. |
| Tank Area 1 Hydrogen Density | Hydrogen concentration detected by the hydrogen detector (for hydrogen tank 1, 2 side) | Min.: 0%, Max.: 399.99% | 0.10% or less:
Vehicle stationary with ignition switch ON (READY) |
- |
| Hydrogen Detector 2 Frequency | Output frequency of the hydrogen detector (for hydrogen tank 3 side) | Min.: 0 kHz, Max.: 65.535 kHz | - | Hydrogen detector output frequency is less than 0.75 kHz, it is suspected that an open or short has occurred in the sensor circuit. |
| Tank Area 2 Hydrogen Density | Hydrogen concentration detected by the hydrogen detector (for hydrogen tank 3 side) | Min.: 0%, Max.: 399.99% | 0.10% or less:
Vehicle stationary with ignition switch ON (READY) |
- |
| Hydrogen Gas Empty | Hydrogen tank assembly has been depleted | ON/OFF | OFF:
Ignition switch ON (READY) |
Tank depletion is measured through the medium-range hydrogen pressure. |
| Purge Amount Estimate Value | Purge amount estimated value due to the exhaust drainage valve opening | Min.: 0 L, Max.: 3999.38 L | - | - |
| Hydrogen Gas Level | Remaining amount of the hydrogen inside the hydrogen tank assembly | Min.: 0%, Max.: 127.5% | - | The remaining amount of the hydrogen inside the tank is calculated based on the value from the hydrogen tank pressure sensor (for outlet side) |
| Exhaust Drainage Valve | Open requests to the exhaust drainage valve | Open/Close | Open:
Requesting the exhaust drainage valve to open |
- |
| Water Heating Heater Consumption Power | Electric heater sub-assembly power consumption | Min.: 0 kW, Max.: 12.75 kW | - | - |
| Water Heating Heater Drive Request | Electric heater sub-assembly drive request | ON/OFF | - | - |
| Water Heating Heater STB Status | Electric heater sub-assembly standby status | None / OFF / ON / Clogged | - | - |
| Water Heating Heater Drive Signal Status | Electric heater sub-assembly drive signal status | ON/OFF | - | - |
| Water Heating Heater Drive Power | Electric heater sub-assembly drive power | Min.: 0 W, Max.: 65535 W | - | - |
| Hydrogen Tank 1 Temperature at Hydrogen Filling | Hydrogen temperature inside the No. 1 hydrogen tank assembly during hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 1 Temperature (Filtered Value) | Hydrogen temperature filtered value in the No. 1 hydrogen tank assembly | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | Almost same as ambient temperatures:
8 hours have elapsed after the ignition switch is turned off |
- |
| Hydrogen Tank 1 Temperature Sensor Voltage | Output voltage of the hydrogen temperature sensor in the No. 1 hydrogen tank assembly | Min.: 0 V, Max.: 4.99 V | - | If the hydrogen temperature sensor is more than 4.9 V or less than 0.1 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Hydrogen Tank 1 Temperature (1 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 1 hydrogen tank assembly 1 second prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 1 Temperature (2 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 1 hydrogen tank assembly 2 seconds prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 1 Temperature (3 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 1 hydrogen tank assembly 3 seconds prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 1 Temperature at Hydrogen Filling Abort | Hydrogen temperature inside the No. 1 hydrogen tank assembly when hydrogen refilling stopped | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 2 Temperature at Hydrogen Filling | Hydrogen temperature inside the No. 2 hydrogen tank assembly during hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 2 Temperature (Filtered Value) | Hydrogen temperature filtered value in the No. 2 hydrogen tank assembly | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | Almost same as ambient temperatures:
8 hours have elapsed after the ignition switch is turned off |
- |
| Hydrogen Tank 2 Temperature Sensor Voltage | Output voltage of the hydrogen temperature sensor in the No. 2 hydrogen tank assembly | Min.: 0 V, Max.: 4.99 V | - | If the hydrogen temperature sensor is more than 4.9 V or less than 0.1 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Hydrogen Tank 2 Temperature (1 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 2 hydrogen tank assembly 1 second prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 2 Temperature (2 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 2 hydrogen tank assembly 2 seconds prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 2 Temperature (3 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 2 hydrogen tank assembly 3 seconds prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 2 Temperature at Hydrogen Filling Abort | Hydrogen temperature inside the No. 2 hydrogen tank assembly when hydrogen refilling stopped | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 3 Temperature at Hydrogen Filling | Hydrogen temperature inside the No. 3 hydrogen tank assembly during hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 3 Temperature (Filtered Value) | Hydrogen temperature filtered value in the No. 3 hydrogen tank assembly | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | Almost same as ambient temperatures:
8 hours have elapsed after the ignition switch is turned off |
- |
| Hydrogen Tank 3 Temperature Sensor Voltage | Output voltage of the hydrogen temperature sensor in the No. 3 hydrogen tank assembly | Min.: 0 V, Max.: 4.99 V | - | If the hydrogen temperature sensor is more than 4.9 V or less than 0.1 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Hydrogen Tank 3 Temperature (1 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 3 hydrogen tank assembly 1 second prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 3 Temperature (2 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 3 hydrogen tank assembly 2 seconds prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 3 Temperature (3 sec before Hydrogen Filling Abort) | Hydrogen temperature inside the No. 3 hydrogen tank assembly 3 seconds prior to stopping hydrogen filling | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Tank 3 Temperature at Hydrogen Filling Abort | Hydrogen temperature inside the No. 3 hydrogen tank assembly when hydrogen refilling stopped | Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) | - | - |
| Hydrogen Intake Pressure (1 sec before Hydrogen Filling Abort) | Hydrogen tank pressure sensor (for inlet side) 1 second prior to stopping hydrogen filling | Min.: 0 kPa, Max.: 655350 kPa | - | - |
| Hydrogen Intake Pressure (2 sec before Hydrogen Filling Abort) | Hydrogen tank pressure sensor (for inlet side) 2 seconds prior to stopping hydrogen filling | Min.: 0 kPa, Max.: 655350 kPa | - | - |
| Hydrogen Intake Pressure (3 sec before Hydrogen Filling Abort) | Hydrogen tank pressure sensor (for inlet side) 3 seconds prior to stopping hydrogen filling | Min.: 0 kPa, Max.: 655350 kPa | - | - |
| Hydrogen Intake Pressure at Hydrogen Filling Abort | Hydrogen tank pressure sensor (for inlet side) when hydrogen refilling stopped | Min.: 0 kPa, Max.: 655350 kPa | - | - |
| Hydrogen Intake Pressure at Hydrogen Filling | Hydrogen tank pressure sensor (for inlet side) during hydrogen filling | Min.: 0 kPa, Max.: 655350 kPa | - | - |
| Hydrogen Tank SOC (1 sec before Hydrogen Filling Abort) | Hydrogen tank assembly hydrogen filling ratio 1 second prior to stopping hydrogen filling | Min.: 0%, Max.: 127.5% | - | - |
| Hydrogen Tank SOC (2 sec before Hydrogen Filling Abort) | Hydrogen tank assembly hydrogen filling ratio 2 seconds prior to stopping hydrogen filling | Min.: 0%, Max.: 127.5% | - | - |
| Hydrogen Tank SOC (3 sec before Hydrogen Filling Abort) | Hydrogen tank assembly hydrogen filling ratio 3 seconds prior to stopping hydrogen filling | Min.: 0%, Max.: 127.5% | - | - |
| Hydrogen Tank SOC at Hydrogen Filling Abort | Hydrogen tank assembly hydrogen filling ratio when hydrogen refilling stopped | Min.: 0%, Max.: 127.5% | - | - |
| Main Radiator Fan Voltage | Cooling fan controller with motor drive voltage | Min.: 0 V, Max.: 25.5 V | - | - |
| Main Radiator Fan Control Duty | Actuation request duty of the cooling fan controller with motor | Min.: -200%, Max.: 199.99% | - | - |
| Radiator Outlet Coolant Temperature Sensor Voltage | Output voltage of the water temperature sensor (for radiator outlet side) | Min.: 0 V, Max.: 4.99 V | - | If the "Radiator Outlet Coolant temperature Sensor Voltage" is more than 4.90 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit, or the FC system operated in a FC stack coolant temperature was below -30°C (-22°F) or over 120°C (248°F) (output limitation did not be activated). |
| Radiator Outlet Coolant Temperature (Filtered Value) | Coolant temperature filtered value of the radiator outlet | Min.: -40°C (-40°F), Max.: 215.9°C (421°F) | 50°C (122°F) to 85°C (185°F):
After warming up |
- |
| FCV System Status | FCV system status | Stop / Preparing / Startup / Working / Finishing / Stopping / Reboot Preparing | - | - |
| FCDC Permission Current | FC boost converter permissible current value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| FCDC Input Voltage | FC boost converter input voltage sensor value | Min.: 0 V, Max.: 6553.5 V | 0 to 330 V:
Ignition switch ON (READY) |
Value of the FVL sensor located inside the FC boost converter |
| FCDC Output Voltage | FC boost converter output voltage sensor value | Min.: 0 V, Max.: 6553.5 V | 0 to 650 V:
Ignition switch ON (READY) |
Value of the FVH sensor located inside the FC boost converter |
| Master Warning Lighting Request (FCDC) | Master warning light illumination request signal from the FC boost control ECU | ON/OFF | OFF:
Ignition switch ON (READY) |
- |
| FCDC Fail Signal | Fail signal from the FC boost control ECU | ON/OFF | - | - |
| Fail Safe Request | Fail safe request from the FC boost control ECU | No Fail Safe / Fail Safe1 / Fail Safe2 / Fail Safe3 / Fail Safe4 | - | - |
| Fail Safe Status (FCDC CAN Communication Status) | Fail safe status according to CAN communication status of the FC boost control ECU | ON/OFF | OFF:
Ignition switch ON (READY) |
- |
| Communication Error from Cell Monitor to FCDC | Communication error from the cell monitor to the FC boost control ECU | ON/OFF | OFF:
Ignition switch ON (READY) |
- |
| Cell Monitor AD Abnormal | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor ROM Abnormal | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor RAM Abnormal | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor Abnormal 1 | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor Abnormal 2 | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor Abnormal 1 (First Out) | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor Abnormal 2 (First Out) | Malfunctions of the cell monitor | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor Power Supply Voltage Low | Malfunctions of the cell monitor or auxiliary battery | ON/OFF | OFF:
Conditions other than malfunction |
- |
| Cell Monitor Power Supply Voltage | Power supply voltage of the cell monitor | Min.: 0 V, Max.: 4.99 V | - | - |
| Ion Exchanger Maintenance Distance | Ion exchanger maintenance distance | Min.: 0 [km] (0 [mile]), Max.: 6553500 [km] (472345 [mile]) | - | - |
| Water Vapor Dilution Control Status | Water vapor dilution control status | Inactive/Active | Active:
Water vapor dilution controlled Inactive: Normal |
- |
| Water Vapor Dilution Control Temperature | Water vapor dilution control temperature | Min.: -64°C (-83.2°F), Max.: 63.5°C (146.3°F) | - | - |
| Conductivity Reduction Complete | Conductivity reduction complete | ON/OFF | - | - |
| Number of Filling | Number of filling | Min.: 0, Max.: 65535 | - | - |
ACTIVE TEST (EV)
Using the GTS to perform Active Tests allows actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
After performing the Active Test, turn the ignition switch off before proceeding to the next step.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / EV / Active Test.
According to the display on the GTS perform the appropriate Active Test.
| Tester Display | Measurement Item | Restrict Condition | Diagnostic Note |
|---|---|---|---|
| Control the Radiator Fan 1 | Drive the cooling fan controller with motor | Ignition switch ON | ·
Control Range 0.1 to 13.7 V ·
Visually check or listen to sound for the radiator fan operation. |
| Control the Select Hydrogen Injector | Injectors can be selected to operate (but the valve cannot be opened forcefully)*1 | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
"Low-Range Hydrogen Pressure (Filtered Value)" in the Data List shows a value less than 270 kPa(abs) ·
Hydrogen secondary pressure sensor is not abnormal ·
Number of injecting fuel injector assemblies is 1 |
·
Control Range #1/#2/#3 ·
Related Data List -
Hydrogen Injector 1 Injection Period -
Hydrogen Injector 2 Injection Period -
Hydrogen Injector 3 Injection Period -
Low-Range Hydrogen Pressure (Filtered Value) ·
Valve opening of a fuel injector assembly can be identified by an increase in the "Low-Range Hydrogen Pressure (Filtered Value)" when an injection request flag has turned ON. ·
By actuating the injectors from 1 to 3 in sequence, increases in the "Low-Range Hydrogen Pressure (Filtered Value)" values during injection can be compared ·
See waveform 1 |
| Activate the Exhaust Drainage Valve | Operation checks for the exhaust drainage valve | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent |
·
Valve opens for 1 second after request Related Data List
-
Exhaust Drainage Valve |
| Activate the FC Water Drainage | Forced drain | ·
Ignition switch ON (READY) ·
Shift state in park (P) |
·
By turning the ignition switch off after selection, if the FC is cool it warms up, and then forced drain can be performed in the stack. |
| FC Stack Inspection Mode | Switching to FC stack inspection mode | ·
Ignition switch ON (READY) ·
Shift state in park (P) |
·
Switching to FC stack inspection mode performs forced power generation of specified current (around 25 to 50 A) for approximately 6 minutes during idling. |
| Activate the FC Precharge Relay | Operation checks for the FC relay precharge side (FRP) | ·
Ignition switch ON ·
SMR (System Main Relay) is not connected ·
BATT Voltage is below 10 V |
·
FC relay forced actuation is allowed for one side only ·
If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur. Relating Data List items:
-
SMRB Status -
SMRG Status -
FCDC Input Voltage -
FC Positive Relay Drive Request -
FC Negative Relay Drive Request -
FC Precharge Relay Drive Request |
| Activate the FC Negative Relay | Operation checks for the FC relay negative side (FRG) | ·
Ignition switch ON ·
SMR (System Main Relay) is not connected ·
BATT Voltage is below 10 V |
·
FC relay forced actuation is allowed for one side only ·
If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur. Relating Data List items:
-
SMRB Status -
SMRG Status -
FCDC Input Voltage -
FC Positive Relay Drive Request -
FC Negative Relay Drive Request -
FC Precharge Relay Drive Request |
| Activate the FC Positive Relay | Operation checks for the FC relay positive side (FRB) | ·
Ignition switch ON ·
SMR (System Main Relay) is not connected ·
BATT Voltage is below 10 V |
·
FC relay forced actuation is allowed for one side only ·
If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur. Relating Data List items:
-
SMRB Status -
SMRG Status -
FCDC Input Voltage -
FC Positive Relay Drive Request -
FC Negative Relay Drive Request -
FC Precharge Relay Drive Request |
| Control the Radiator Rotary Valve | Drive the FC cooling water temperature control valve to a requested opening angle | ·
Shift state in park (P) ·
"FC Stack Outlet Coolant Temperature (Filtered Value)" in the Data List shows 10°C (50°F) to 78°C (172.4°F) |
·
Control Range 1 to 100% 1%: FC stack → Radiator passage is closed 100%: FC stack → Radiator passage is opened ·
Related Data List -
Target Radiator Rotary Valve Position -
Radiator Outlet Coolant Temperature (Filtered Value) -
FC Stack Outlet Coolant Temperature (Filtered Value) ·
For inspection instructions for the FC cooling water temperature control valve, refer to FC cooling water temperature control valve operation checks provided in the following page. |
| Control the Air Pressure Regulating Valve | Drive the air pressure regulating valve to a requested opening angle | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
FC Air Compressor Motor Speed is 1800 rpm or less |
·
Control Range 1 to 100% 1%: Air pressure regulating valve is closed 100%: Air pressure regulating valve is opened ·
Related Data List -
Air Pressure Regulating Valve Drive Position -
Target Air Pressure Regulating Valve Position -
Air Pressure Regulating Valve Position |
| Control the Air Shunt Valve | Drive the air shunt valve to a requested opening angle | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
FC Air Compressor Motor Speed is 2000 rpm or less |
·
Control Range 1 to 100% 1%: Air shunt valve is closed 100%: Air shunt valve is opened ·
Related Data List -
Air Shunt Valve Drive Position -
Target Air Shunt Valve Position -
Air Shunt Valve Position |
| Control the Air Sealing Valve | Drive the air sealing valve to a requested opening angle | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
FC Air Compressor Motor Speed is 1800 rpm or less |
·
Control Range 1 to 100% 1%: Air sealing valve is closed 100%: Air sealing valve is opened ·
Related Data List -
Air Sealing Valve Drive Position -
Target Air Sealing Valve Position -
Air Sealing Valve Position |
| Activate the Tank Shut Valve 1 | Operation checks for the tank shut valve 1 | ·
Ignition switch ON ·
No DTCs output for hydrogen primary pressure sensor, hydrogen tank temperature sensor or tank shut valve ·
The pressure of the hydrogen primary pressure sensor is higher than 800 kPa 5 seconds after the value opens ·
Hydrogen tank temperature is -45°C (-49°F) or higher ·
Detected hydrogen concentration is less than 1.2% |
·
Control Range Open/Close ·
Related Data List -
Tank Shut Valve 1 Drive Status -
Tank Shut Valve 1 Status -
Tank Shut Valve Power Relay Drive Status -
Tank Shut Valve Power Relay Drive Signal Status |
| Activate the Tank Shut Valve 2 | Operation checks for the tank shut valve 2 | ·
Ignition switch ON ·
No DTCs output for hydrogen primary pressure sensor, hydrogen tank temperature sensor or tank shut valve ·
The pressure of the hydrogen primary pressure sensor is higher than 800 kPa 5 seconds after the value opens ·
Hydrogen tank temperature is -45°C (-49°F) or higher ·
Detected hydrogen concentration is less than 1.2% |
·
Control Range Open/Close ·
Related Data List -
Tank Shut Valve 2 Drive Status -
Tank Shut Valve 2 Status -
Tank Shut Valve Power Relay Drive Status -
Tank Shut Valve Power Relay Drive Signal Status |
| Activate the Tank Shut Valve 3 | Operation checks for the tank shut valve 3 | ·
Ignition switch ON ·
No DTCs output for hydrogen primary pressure sensor, hydrogen tank temperature sensor or tank shut valve ·
The pressure of the hydrogen primary pressure sensor is higher than 800 kPa 5 seconds after the value opens ·
Hydrogen tank temperature is -45°C (-49°F) or higher ·
Detected hydrogen concentration is less than 1.2% |
·
Control Range Open/Close ·
Related Data List -
Tank Shut Valve 3 Drive Status -
Tank Shut Valve 3 Status -
Tank Shut Valve Power Relay Drive Status -
Tank Shut Valve Power Relay Drive Signal Status |
| Control the Hydrogen Pump | Drive the hydrogen pump to a requested pump speed | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
For 60 seconds after an Active Test is requested |
·
Control Range 600 to 6800 rpm ·
Related Data List -
Hydrogen Pump Drive Speed -
Hydrogen Pump Speed -
Target Hydrogen Pump Speed ·
"Hydrogen Pump Speed" is normally within a "Target Hydrogen Pump Speed" +/-200 rpm (e.g. 2000 +/-200 rpm) ·
Operating sound can be heard from the operating hydrogen pump ·
See waveform 2
|
| Control the FC Coolant Pump | Drive the FC cooling water pump assembly to a requested pump speed | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
For 60 seconds after an Active Test is requested |
·
Control Range 500 to 5700 rpm ·
Related Data List -
FC Coolant Pump Drive Speed -
FC Coolant Pump Speed -
Target FC Coolant Pump Speed -
FC Stack Outlet Coolant Temperature (Filtered Value) -
Radiator Outlet Coolant Temperature (Filtered Value) ·
"FC Coolant Pump Speed" is normally within a "Target Hydrogen Pump Speed" +/-100 rpm (e.g. 1500 +/-100 rpm) ·
Operating sound can be heard from the operating FC cooling water pump assembly ·
See waveform 3
|
| Control the FC Air Compressor | Drive the FC air compressor with motor assembly to a requested motor speed | ·
Shift state in park (P) ·
Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working ·
"FC Power Generation Status" in the Data List shows Normal or Intermittent ·
For 60 seconds after an Active Test is requested |
·
Control Range 100 to 16700 rpm ·
Related Data List -
FC Air Compressor Motor Drive Speed -
FC Air Compressor Motor Speed -
Target FC Air Compressor Motor Speed -
FC Air Compressor Motor Speed (Measured Value) ·
"FC Air Compressor Motor Speed" is normally within a "Target FC Air Compressor Motor Speed" +/-200 rpm (e.g. 2000 +/-200 rpm) ·
Operating sound can be heard from the operating FC air compressor with motor assembly ·
If an air pressure increases too high due to forced continuous revolution increase in the compressor, it will be interpreted as a malfunction. ·
See waveform 4
|
| Control the Water Heating Heater | Drive the electric heater sub-assembly | ·
Ignition switch ON (READY) ·
Shift state in park (P) ·
Electric heater sub-assembly is normal |
·
Control Range 1 to 7000 W ·
The FC stack power generation current value can be increased by electric heater sub-assembly operation. |
*1: Performing the Active Test "Control the Select Hydrogen Injector" does not forcefully activate injectors. The injector operation remains in normal control mode, and the Active Test is used to select any of the 3 injectors to operate.
Connect the GTS to the DLC3.
Put the state in park (P), turn the ignition switch to ON (READY), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.
Enter the following menus: Powertrain / EV / Active Test / Control the Radiator Rotary Valve
In addition, select "FC Stack Outlet Coolant Temperature (Filtered Value)" in the Data List.
Using Active Tests, set the "Control the Radiator Rotary Valve" to 0%, and check the "FC Stack Outlet Coolant Temperature (Filtered Value)" by turning the air conditioning ON (Lo/Cool Max, maximum airflow) for 1 minute and then turning it OFF for 1 minute.
The "FC Stack Outlet Coolant Temperature (Filtered Value)" does not change when the air conditioning is in ON or OFF.
Turn on the air conditioning to actuate the radiator fan.
Using Active Tests, set the "Control the Radiator Rotary Valve" to 100%, and check the "FC Stack Outlet Coolant Temperature (Filtered Value)" by turning the air conditioning ON (Lo/Cool Max, maximum airflow) for 1 minute and then turning it OFF for 1 minute.
The "FC Stack Outlet Coolant Temperature (Filtered Value)" changes by 2°C (3.6°F) or more (increases/decreases) when the air conditioning is turned ON or OFF.
Check that the FC cooling water temperature control valve operation is normal by examining the changes in the "FC Stack Outlet Coolant Temperature (Filtered Value)" and inspection results 1 and 2 instructed above.
During normal control, the injector performing injection switches in order from 1 to 2 then 3.
Using an Active Test of the injectors, select an injector to operate. Valve opening of an injector can be identified by an increase in the "Low-Range Hydrogen Pressure (Filtered Value)" when an injection request flag has turned ON.
By selecting the injectors from 1 to 3 in sequence, increases in the "Low-Range Hydrogen Pressure (Filtered Value)" values during injection can be compared. However, if the "Low-Range Hydrogen Pressure (Filtered Value)" increases or it is excessive when an injection request is inactive, it is suspected that any one of the injectors has stuck open.
| GTS Display | Measurement Item | Reference Value | |
|---|---|---|---|
| Control the Hydrogen Pump | - | ▲A | ▲B |
| Target Hydrogen Pump Speed | 900 rpm | 2013 rpm | |
| Hydrogen Pump Speed | 863 rpm | 2015 rpm | |
| Hydrogen Pump Drive Speed | 900 rpm | 2013 rpm | |
| Hydrogen Pump Output Status | Normal | Normal | |
| Hydrogen Pump Load Status | Normal | Normal | |
| Hydrogen Pump Inverter Over Temperature Status | Normal | Normal | |
"Hydrogen Pump Speed" is normally within a "Target Hydrogen Pump Speed" +/-200 rpm.
| GTS Display | Measurement Item | Reference Value | |
|---|---|---|---|
| Control the FC Coolant Pump | - | ▲A | ▲B |
| Target FC Coolant Pump Speed | 825 rpm | 1500 rpm | |
| FC Coolant Pump Speed | 831 rpm | 1490 rpm | |
| FC Coolant Pump Output Status | Normal | Normal | |
| FC Coolant Pump Load Status | Normal | Normal | |
| FC Coolant Pump Over Temperature Status | Normal | Normal | |
"FC Coolant Pump Speed" is normally within a "Target FC Coolant Pump Speed" +/-100 rpm
| GTS Display | Measurement Item | Reference Value | |
|---|---|---|---|
| Control the FC Air Compressor | - | ▲A | ▲B |
| Target FC Air Compressor Motor Speed | 590 rpm | 2000 rpm | |
| FC Air Compressor Motor Speed | 575 rpm | 1987 rpm | |
"FC Air Compressor Motor Speed" is normally within a "Target FC Air Compressor Motor Speed" +/-200 rpm
Data List (FC)
Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / FC / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Drive total distance | Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) | - | - |
| Total Distance Traveled - Unit | Unit of drive total distance | km/mile | - | - |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage (BATT terminal) | Min.: 0 V, Max.: 65.535 V | Constant:
11 to 15 V |
- |
| IG2 Status (Line) | IGSW terminal state | ON/OFF | ON: Ignition switch ON | - |
| IG2 Status (CAN/SIL) | IGSW terminal status received from the EV control ECU | ON/OFF | ON: Ignition switch ON | - |
| Ready Status | State of system (READY) | ON/OFF | ON: Ignition switch ON (READY) | - |
| FCG Relay Drive Request | Actuation requests of the FRG relay | ON/OFF | ON: Ignition switch ON (READY) | - |
| FCB Relay Drive Request | Actuation requests of the FRB relay | ON/OFF | ON: Ignition switch ON (READY) | - |
| High-Range Hydrogen Pressure | Internal pressures of the high-range hydrogen pressure system components | Min.: -200 MPa, Max.: 199.99 MPa | 1.00 to 87.50 MPa:
Vehicle stationary with ignition switch ON (READY) |
This represents a pressure between the tank shut valve and the hydrogen supply regulator assembly |
| Medium-Range Hydrogen Pressure | Internal pressures of the medium-range hydrogen pressure system components | Min.: -3276.8 kPa, Max.: 3276.7 kPa | 1.00 to 1.60 MPa:
Vehicle stationary with ignition switch ON (READY) |
- |
| Low-Range Hydrogen Pressure | Internal pressures of the low-range hydrogen pressure system components | Min.: 0 kPa, Max.: 633.35 kPa | "Atmospheric pressure plus 10 kPa" to "280 kPa(abs)":
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF) |
- |
| High-Range Hydrogen Pressure Sensor Voltage | Output voltage of the hydrogen tank pressure sensor (for outlet side) | Min.: 0 V, Max.: 4.99 V | - | If the "High-Range Hydrogen Pressure Sensor Voltage" is more than 4.65 V or less than 0.55 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Medium-Range Hydrogen Pressure Sensor Voltage | Output voltage of the hydrogen primary pressure sensor | Min.: 0 V, Max.: 4.99 V | - | If the "Medium-Range Hydrogen Pressure Sensor Voltage" is more than 4.72 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Low-Range Hydrogen Pressure Sensor Voltage | Output voltage of the hydrogen secondary pressure sensor | Min.: 0 V, Max.: 4.99 V | - | If the "Low-Range Hydrogen Pressure Sensor Voltage" is more than 4.72 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Exhaust Drainage Valve Status | Actuation requests of the exhaust drainage valve | Open/Close | Open: Exhaust drainage valve operating | - |
| Exhaust Drainage Valve Terminal Voltage | Exhaust drainage valve voltage | Min.: 0 V, Max.: 4.99 V | - | - |
| Air Valve Supply Voltage | Power source voltage of the air valve | Min.: 0 V, Max.: 79.99 V | - | - |
| Air Shunt Valve FAIL Signal Status (Open Side) | Air shunt valve fail signal status (open side) | High/Low | - | - |
| Air Sealing Valve FAIL Signal Status (Open Side) | Air sealing valve fail signal status (open side) | High/Low | - | - |
| Air Pressure Regulating Valve FAIL Signal Status (Open Side) | Air pressure regulating valve fail signal status (open side) | High/Low | - | - |
| Air Shunt Valve FAIL Signal Status (Close Side) | Air shunt valve fail signal status (close side) | High/Low | - | - |
| Air Sealing Valve FAIL Signal Status (Close Side) | Air sealing valve fail signal status (close side) | High/Low | - | - |
| Air Pressure Regulating Valve FAIL Signal Status (Close Side) | Air pressure regulating valve fail signal status (close side) | High/Low | - | - |
| Air Shunt Valve Operation Wait Status | Air shunt valve operation confirmation status | ON/OFF | ON: Air shunt valve operation confirmation being performed | - |
| Air Sealing Valve Operation Wait Status | Air sealing valve operation confirmation status | ON/OFF | ON: Air sealing valve operation confirmation being performed | - |
| Air Pressure Regulating Valve Operation Wait Status | Air pressure regulating valve operation confirmation status | ON/OFF | ON: Air pressure regulating valve operation confirmation being performed | - |
| Air Shunt Valve Circuit Open Confirmation Status | Air shunt valve open circuit confirmation status | ON/OFF | ON: Air shunt valve open circuit confirmation being performed | - |
| Air Sealing Valve Circuit Open Confirmation Status | Air sealing valve open circuit confirmation status | ON/OFF | ON: Air sealing valve open circuit confirmation being performed | - |
| Air Pressure Regulating Valve Circuit Open Confirmation Status | Air pressure regulating valve open circuit confirmation status | ON/OFF | ON: Air pressure regulating valve open circuit confirmation being performed | - |
| Air Shunt Valve DC Motor Current (Open Side) | Air shunt valve DC motor current (open aside) | Min.: -125 A, Max.: 124.99 A | - | - |
| Air Sealing Valve DC Motor Current (Open Side) | Air sealing valve DC motor current (open aside) | Min.: -125 A, Max.: 124.99 A | - | - |
| Air Pressure Regulating Valve DC Motor Current (Open Side) | Air pressure regulating valve DC motor current (open aside) | Min.: -125 A, Max.: 124.99 A | - | - |
| Air Shunt Valve Motor Duty | Air shunt valve motor control duty | Min.: 0%, Max.: 127.5% | - | - |
| Air Sealing Valve Motor Duty | Air sealing valve motor control duty | Min.: 0%, Max.: 127.5% | - | - |
| Air Pressure Regulating Valve Motor Duty | Air pressure regulating valve motor control duty | Min.: 0%, Max.: 127.5% | - | - |
| Air Shunt Valve Position | Air shunt valve opening angle | Min.: -250 deg, Max.: 249.99 deg | - | - |
| Air Sealing Valve Position | Air sealing valve opening angle | Min.: -250 deg, Max.: 249.99 deg | - | - |
| Air Pressure Regulating Valve Position | Air pressure regulating valve opening angle | Min.: -250 deg, Max.: 249.99 deg | - | - |
| Air Shunt Valve Position Sensor Voltage | Output voltage of the air shunt valve position sensor | Min.: 0 V, Max.: 4.99 V | - | - |
| Air Sealing Valve Position Sensor Voltage | Output voltage of the air sealing valve position sensor | Min.: 0 V, Max.: 4.99 V | - | - |
| Air Pressure Regulating Valve Position Sensor Voltage | Output voltage of the air pressure regulating valve position sensor | Min.: 0 V, Max.: 4.99 V | - | - |
| Radiator Rotary Valve Fail Status (WRA1) | FC cooling water temperature control valve (WRA1) fail status | ON/OFF/Unknown | - | - |
| Radiator Rotary Valve Carrying Request (WRA1) | Actuation requests of the FC cooling water temperature control valve (WRA1) | ON/OFF | - | - |
| Radiator Rotary Valve Fail Status (WRA2) | FC cooling water temperature control valve (WRA2) fail status | ON/OFF/Unknown | - | - |
| Radiator Rotary Valve Carrying Request (WRA2) | Actuation requests of the FC cooling water temperature control valve (WRA2) | ON/OFF | - | - |
| Radiator Rotary Valve Fail Status (WRB1) | FC cooling water temperature control valve (WRB1) fail status | ON/OFF/Unknown | - | - |
| Radiator Rotary Valve Carrying Request (WRB1) | Actuation requests of the FC cooling water temperature control valve (WRB1) | ON/OFF | - | - |
| Radiator Rotary Valve Fail Status (WRB2) | FC cooling water temperature control valve (WRB2) fail status | ON/OFF/Unknown | - | - |
| Radiator Rotary Valve Carrying Request (WRB2) | Actuation requests of the FC cooling water temperature control valve (WRB2) | ON/OFF | - | - |
| Hydrogen Injector 1 Current Offset | No. 1 fuel injector assembly current calibration | ON/OFF | ON: No. 1 fuel injector assembly current calibration being performed | - |
| Hydrogen Injector 2 Current Offset | No. 2 fuel injector assembly current calibration | ON/OFF | ON: No. 2 fuel injector assembly current calibration being performed | - |
| Hydrogen Injector 3 Current Offset | No. 3 fuel injector assembly current calibration | ON/OFF | ON: No. 3 fuel injector assembly current calibration being performed | - |
| Hydrogen Injector 1 Terminal Status | No. 1 fuel injector assembly terminal status | High/Low | High: Ignition switch ON (READY) | - |
| Hydrogen Injector 2 Terminal Status | No. 2 fuel injector assembly terminal status | High/Low | High: Ignition switch ON (READY) | - |
| Hydrogen Injector 3 Terminal Status | No. 3 fuel injector assembly terminal status | High/Low | High: Ignition switch ON (READY) | - |
| Hydrogen Injector 1 Injection | Injection requests to No. 1 fuel injector assembly | ON/OFF | ON:
Requesting No. 1 fuel injector assembly to inject |
- |
| Hydrogen Injector 2 Injection | Injection requests to No. 2 fuel injector assembly | ON/OFF | ON:
Requesting No. 2 fuel injector assembly to inject |
- |
| Hydrogen Injector 3 Injection | Injection requests to No. 3 fuel injector assembly | ON/OFF | ON:
Requesting No. 3 fuel injector assembly to inject |
- |
| FC Air Compressor Motor Temperature Sensor Voltage | Output voltage of the FC air compressor motor temperature sensor | Min.: 0 V, Max.: 4.99 V | - | - |
| Emergency Shutdown Signal | Emergency shutdown signal | ON/OFF | OFF: Constant | - |
Data List (FCDC)
Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / FCDC / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Drive total distance | Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) | - | - |
| Total Distance Traveled - Unit | Unit of drive total distance | km/mile | - | - |
| IG2 Status (Line) | IGSW terminal condition | ON/OFF | ON: Ignition switch ON | - |
| Ready Status | State of system (READY) | ON/OFF | ON: Ignition switch ON (READY) | - |
| Shutdown Request (Hybrid/EV) | Inverter shutdown signal status | ON/OFF | - | - |
| Inverter Shutdown Status | Inverter shutdown status | ON/OFF | - | - |
| Fail Safe Status | Control data for fail-safe control | ON/OFF | - | - |
| Total Voltage | FC stack power generation voltage calculated from the cell monitor (Total amount of each cell voltages) | Min.: 0 V, Max.: 1023.98 V | 0 to 330 V | - |
| FC Voltage (Filtered Value) | FC converter input voltage sensor filtered value (voltage before boosting) | Min.: -3276.8 V, Max.: 3276.7 V | 0 to 330 V | - |
| FC Converter Output Voltage (Filtered Value) | FC converter output voltage sensor filtered value (voltage after boosting) | Min.: -3276.8 V, Max.: 3276.7 V | 0 to 650 V | - |
| FC Voltage | FC converter input voltage sensor value (voltage before boosting) | Min.: 0 V, Max.: 6553.5 V | 0 to 330 V | Value of the FVL sensor located inside the FC converter |
| FC Converter Output Voltage | FC converter output voltage sensor value (voltage after boosting) | Min.: -3276.8 V, Max.: 3276.7 V | 0 to 650 V | Value of the FVH sensor located inside the FC converter |
| Power Supply Monitor Voltage (+B) | +B1, +B2 terminal voltage | Min.: 0 V, Max.: 4.98 V | - | - |
| Power Supply Monitor Voltage (-5V) | -5 V Power source CPU input AD value | Min.: 0 V, Max.: 4.98 V | - | - |
| VH Voltage | Inverter voltage sensor value (voltage after boosting) | Min.: 0 V, Max.: 1023.98 V | 0 to 330 V | - |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage | Min.: 0 V, Max.: 65.535 V | - | - |
| FC Current | FC current sensor value | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 600 A | - |
| FC Current Upper Limit | FC current upper limit when limiting output | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 600 A | Maximum FC current value that is currently allowed when the FC boost control ECU must limit output |
| Target FC Current (Hybrid/EV) | Output current command value for the FC system | Min.: 0 A, Max.: 3999.93 A | 0 to 600 A | - |
| FC Current (Filtered Value) | FC current filtered value | Min.: 0 A, Max.: 3999.93 A | 0 to 600 A | - |
| FCP Relay Drive Request | Actuation requests of the FRP relay | ON/OFF | - | - |
| FCG Relay Drive Request | Actuation requests of the FRG relay | ON/OFF | - | - |
| FCB Relay Drive Request | Actuation requests of the FRB relay | ON/OFF | - | - |
| Hybrid/EV Coolant Temperature | EV coolant temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Phase U Duty | Phase U current duty value | Min.: 0%, Max.: 399.99% | 0 to 98% | - |
| Phase U Temperature 1 | Phase U temperature 1 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 1 converted to temperature |
| Phase U Temperature 2 | Phase U temperature 2 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 2 converted to temperature |
| Phase U Temperature 1 Duty | Phase U temperature sensor 1 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase U. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase U Temperature 2 Duty | Phase U temperature sensor 2 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase U. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase U Temperature 1 (Filtered Value) | Phase U temperature filtered value | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Filtered value of either phase U temperature 1 or phase U temperature 2, whichever is largest |
| Phase U Current | Phase U current | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 150 A | - |
| Phase U Current AD Value | AD value of phase U current | Min.: 0 V, Max.: 4.99 V | - | - |
| Phase U Current (Offset Value) | Phase U current offset value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Phase V Duty | Phase V current duty value | Min.: 0%, Max.: 399.99% | 0 to 98% | - |
| Phase V Temperature 1 | Phase V temperature 1 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 1 converted to temperature |
| Phase V Temperature 2 | Phase V temperature 2 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 2 converted to temperature |
| Phase V Temperature 1 Duty | Phase V temperature sensor 1 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase V. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase V Temperature 2 Duty | Phase V temperature sensor 2 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase V. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase V Temperature 1 (Filtered Value) | Phase V temperature filtered value | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Filtered value of either phase V temperature 1 or phase V temperature 2, whichever is largest |
| Phase V Current | Phase V current | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 150 A | - |
| Phase V Current AD Value | AD value of phase V current | Min.: 0 V, Max.: 4.98 V | - | - |
| Phase V Current (Offset Value) | Phase V current offset value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Phase W Duty | Phase W current duty value | Min.: 0%, Max.: 399.99% | 0 to 98% | - |
| Phase W Temperature 1 | Phase W temperature 1 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 1 converted to temperature |
| Phase W Temperature 2 | Phase W temperature 2 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 2 converted to temperature |
| Phase W Temperature 1 Duty | Phase W temperature sensor 1 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase W. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase W Temperature 2 Duty | Phase W temperature sensor 2 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase W. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase W Temperature 1 (Filtered Value) | Phase W temperature filtered value | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Filtered value of either phase W temperature 1 or phase W temperature 2, whichever is largest |
| Phase W Current | Phase W current | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 150 A | - |
| Phase W Current AD Value | AD value of phase W current | Min.: 0 V, Max.: 4.98 V | - | - |
| Phase W Current (Offset Value) | Phase W current offset value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
| Phase X Duty | Phase X current duty value | Min.: 0%, Max.: 399.99% | 0 to 98% | - |
| Phase X Temperature 1 | Phase X temperature 1 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 1 converted to temperature |
| Phase X Temperature 2 | Phase X temperature 2 | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Value of output duty from the temperature sensor 2 converted to temperature |
| Phase X Temperature 1 Duty | Phase X temperature sensor 1 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase X. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase X Temperature 2 Duty | Phase X temperature sensor 2 output duty value | Min.: 0%, Max.: 399.99% | - | There are 2 switching elements configured in a line for phase X. A temperature sensor is attached to each element for use in measuring the temperature. |
| Phase X Temperature 1 (Filtered Value) | Phase X temperature filtered value | Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) | 15°C (59°F) to 150°C (302°F) | Filtered value of either phase X temperature 1 or phase X temperature 2, whichever is largest |
| Phase X Current | Phase X current | Min.: -3276.8 A, Max.: 3276.7 A | 0 to 150 A | - |
| Phase X Current AD Value | AD value of phase X current | Min.: 0 V, Max.: 4.98 V | - | - |
| Phase X Current (Offset Value) | Phase X current offset value | Min.: -3276.8 A, Max.: 3276.7 A | - | - |
Data List (HYDROGEN FILLING CONTROL)
Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Hydrogen Filling Control / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Total Distance Traveled | Drive total distance | Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) | - | - |
| Total Distance Traveled - Unit | Unit of drive total distance | km/mile | - | - |
| IG2 Status | IGSW terminal state | ON/OFF | ON: Ignition switch ON | - |
| Ready Status | State of system (READY) | ON/OFF | ON: Ignition switch ON (READY) | - |
| Vehicle Speed | Vehicle speed | Min.: 0 km (0 mile), Max.: 255 km (158 mile) | 0 km/h (0 mph):
Vehicle stopped No significant fluctuation: While driving at a constant speed |
- |
| Smoothed Value of BATT Voltage | Smoothed value of auxiliary battery voltage (BATT terminal) | Min.: 0 V, Max.: 65.535 V | Constant:
11 to 15 V |
- |
| System Power Supply Relay Drive Signal | HF-B relay actuation signal | ON/OFF | ON: Ignition switch ON | The EV control ECU switches the HF-B relay on or off. |
| Hydrogen Intake Pressure Sensor Voltage | Output voltage of the hydrogen tank pressure sensor (for inlet side) | Min.: 0 V, Max.: 4.99 V | - | If the "Hydrogen Intake Pressure Sensor Voltage" is more than 4.95 V or less than 0.55 V, it is suspected that an open or short has occurred in the sensor circuit. |
| Hydrogen Intake Pressure Sensor Power Supply Voltage | Power source voltage of the hydrogen tank pressure sensor (for inlet side) | Min.: 0 V, Max.: 4.99 V | - | - |
| Hydrogen Intake Pressure Sensor Power Supply Status | Status of the hydrogen tank pressure sensor (for inlet side) power source | ON/OFF | - | - |
| Hydrogen Tank Temperature Sensor Power Supply Status | Status of the built-in hydrogen temperature sensor power source of the hydrogen tank assembly | ON/OFF | - | - |
| Hydrogen Tank 1 Temperature Sensor Voltage | Output voltage of the built-in hydrogen temperature sensor of the No. 1 hydrogen tank assembly | Min.: 0 V, Max.: 4.99 V | - | - |
| Hydrogen Tank 2 Temperature Sensor Voltage | Output voltage of the built-in hydrogen temperature sensor of the No. 2 hydrogen tank assembly | Min.: 0 V, Max.: 4.99 V | - | - |
| Hydrogen Tank 3 Temperature Sensor Voltage | Output voltage of the built-in hydrogen temperature sensor of the No. 3 hydrogen tank assembly | Min.: 0 V, Max.: 4.99 V | - | - |
| Number of Tanks (Memory) | Number of hydrogen tanks assemblies stored by the hydrogen fuel control ECU | Min.: 0, Max.: 255 | 3 | - |
| Number of Tanks (Hybrid/EV Control) | Number of tanks received from the EV control ECU | Min.: 0, Max.: 255 | 3 | - |
| Number of Tanks (Recognition) | Number of tanks read from the Hydrogen Tank 3 Temperature Sensor Voltage | Min.: 0, Max.: 255 | 3 | - |
| Lid Open Relay | FUEL LID OPN relay status | ON/OFF | ON: FUEL LID OPN relay is operating | - |
| Tank Shut Valve Power Supply Relay Driving Status | HF-B relay actuation status | ON/OFF | ON: Ignition switch ON
OFF: Ignition switch off |
The EV control ECU switches the H2 SHUT VLV relay on or off. |
| Tank Shut Valve 1 Current Keeping Control Status | Current keeping control status to the tank shut valve of the No. 1 hydrogen tank assembly | ON/OFF | ON: Ignition switch ON (READY)
OFF: READY off |
- |
| Tank Shut Valve 2 Current Keeping Control Status | Current keeping control status to the tank shut valve of the No. 2 hydrogen tank assembly | ON/OFF | ON: Ignition switch ON (READY)
OFF: READY off |
- |
| Tank Shut Valve 3 Current Keeping Control Status | Current keeping control status to the tank shut valve of the No. 3 hydrogen tank assembly | ON/OFF | ON: Ignition switch ON (READY)
OFF: READY off |
- |
| Tank Shut Valve 1 Drive Request | Actuation requests to the tank shut valve of the No. 1 hydrogen tank assembly | ON/OFF | ON: Ignition switch ON (READY)
OFF: READY off |
Requests are off during hydrogen leak inspection of vehicle control |
| Tank Shut Valve 2 Drive Request | Actuation requests to the tank shut valve of the No. 2 hydrogen tank assembly | ON/OFF | ON: Ignition switch ON (READY)
OFF: READY off |
Requests are off during hydrogen leak inspection of vehicle control |
| Tank Shut Valve 3 Drive Request | Actuation requests to the tank shut valve of the No. 2 hydrogen tank assembly | ON/OFF | ON: Ignition switch ON (READY)
OFF: READY off |
Requests are off during hydrogen leak inspection of vehicle control |
| Tank Shut Valve 1 Voltage | Output voltage of the No. 1 hydrogen tank assembly (tank shut valve 1) | Min.: 0 V, Max.: 4.99 V | - | - |
| Tank Shut Valve 2 Voltage | Output voltage of the No. 2 hydrogen tank assembly (tank shut valve 2) | Min.: 0 V, Max.: 4.99 V | - | - |
| Tank Shut Valve 3 Voltage | Output voltage of the No. 3 hydrogen tank assembly (tank shut valve 3) | Min.: 0 V, Max.: 4.99 V | - | - |
| Infrared Transmitter Power Supply Malfunction | Power source malfunction of the hydrogen fuel control transmitter | ON/OFF | ON: Hydrogen fuel control transmitter power source abnormal | - |
| Infrared Transmitter Power Supply Status | Status of the hydrogen fuel control transmitter power source | ON/OFF | ON: Hydrogen fuel control transmitter operating | - |
| Infrared Transmitter Power Supply Voltage | Power source voltage of the hydrogen fuel control transmitter | Min.: 0 V, Max.: 4.99 V | - | - |