Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM › from 2021.08
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM U

FC CONTROL  FC CONTROL SYSTEM  DATA LIST / ACTIVE TEST  


Data List (EV)


NOTICE:
·

Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.

·

In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.



HINT:

Data List relating to hydrogen filling

While the hydrogen tank is filled, turning the ignition switch to ON allows a GTS to access the Data List for the hydrogen filling. When accessing, communication error DTCs could be output. If this happens, clear such DTCs.



a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / EV / Data List.


e.

Check the results by referring to the following table.

HINT:

For hybrid (EV) control items, refer to Hybrid Control System.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DATA LIST / ACTIVE TEST


Powertrain > EV > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Vehicle Speed Vehicle speed Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) Vehicle stopped:
0 km/h (0 mph)
While driving at a constant speed:
No significant fluctuation
-
Accelerator Position Accelerator pedal depressed angle Min.: 0%, Max.: 125.7% Accelerator pedal depressed:
Changes with accelerator pedal pressure
-
Shift Position Shift position P/R/N/D/B Matches currently selected shift position:
P, R, N, D or B
-
Atmospheric Pressure Sensor Voltage Output voltage of the barometric pressure sensor Min.: 0 V, Max.: 4.99 V - If the "Atmospheric Pressure Sensor Voltage" is more than 4.70 V or less than 0.30 V, it is suspected that an open or short has occurred in the sensor circuit.
Atmospheric Pressure Atmospheric pressure Min.: 0 kPa, Max.: 655.35 kPa -
·

Standard atmospheric pressure is approximately 101 kPa (15 psi).

·

For every 100 m (328 ft.) increase in altitude, atmospheric pressure drops by approximately 1 kPa (0.1 psi). This varies by weather.

·

Barometric pressure sensor value is built into the EV control ECU.


Atmospheric Pressure (Filtered Value) Atmospheric pressure filtered value Min.: 0 kPa, Max.: 655.35 kPa - -
Ambient Temperature Ambient air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Ignition switch ON:
Same as ambient air temperature
-
Intake Air Temperature Sensor Voltage Output voltage of the intake air temperature sensor Min.: 0 V, Max.: 4.99 V - If the "Intake Air Temperature Sensor Voltage" is more than 4.90 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit.
Intake Air Temperature (Filtered Value) Intake air temperature filtered value Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Mass Air Flow Sensor Frequency Output frequency of the mass air flow meter sub-assembly Min.: 0 kHz, Max.: 12.75 kHz - -
Target Mass Air Flow Target supply air volume to the FC stack Min.: 0 L/min, Max.: 39999.38 L/min - -
Mass Air Flow (Filtered Value) Airflow rate from mass air flow meter sub-assembly Min.: 0 L/min, Max.: 39999.38 L/min - -
Estimate Gradient of Road Surface (Right and Left) Tilt angle in the lateral (left-right) direction of the vehicle Min.: -25.6 deg, Max.: 25.4 deg 0 deg:
Vehicle stopped on a flat surface with no tilt
Leaving the vehicle in READY ON state for a long time in a location with a large left-right tilt may result in FC power generation stop due to poor drainage.
Ready Lighting Request (Normal Start) READY lighting request status during normal start ON/OFF ON: Ignition switch ON (READY) -
Freeze Start Rejection FC system could not start up due to freezing ON/OFF - -
BATT Voltage BATT voltage Min.: 0 V, Max.: 79.99 V - BATT terminal voltage of the EV control ECU.
Total Voltage FC stack power generation voltage calculated from the cell monitor (Total amount of each cell voltages) Min.: 0 V, Max.: 3553.5 V 0 to 330.0 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
Internal Voltage Power supply voltage applied from the FC-B relay Min.: 0 V, Max.: 3553.5 V 11.00 to 14.70 V:
Ignition switch ON
This is the power supply voltage that is used to actuate the following valves:
Air sealing valve, air shunt valve, air pressure regulating valve, exhaust drainage valve, FC cooling water temperature control valve.
Input Power A/C consumption power Min.: 0 kW, Max.: 12.75 kW 0 to 5.00 kW:
While the air conditioning system is operating
-
Internal Power Supply Voltage (VHMR) Power source voltage of the hydrogen detector (for front compartment side) Min.: 0 V, Max.: 79.99 V 0 to 5.1 V -
Total Distance Traveled Drive total distance Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) - -
Total Distance Traveled - Unit Unit of drive total distance km/mile - -
IG2 Signal Status IG2 signal status ON/OFF ON: Ignition switch ON -
Ready Signal State of system (READY) ON/OFF ON: Ignition switch ON (READY) -
HV/EV Activate Condition Indicates the EV start condition Normal/Remote Air Control System/Remote - -
Fuel Lid Interlock Switch Fuel lid interlock switch condition ON/OFF ON:
Fuel lid open
OFF:
Fuel lid fully closed
The interlock switch is used to prevent the vehicle from running while the hydrogen filling nozzle is connected to the vehicle. Thus, the interlock switch monitors if the fuel lid is open or closed.
Fuel Lid Open Switch Fuel lid opener switch ON/OFF ON:
Fuel lid opener switch pressed
-
FC Precharge Relay Drive Request Actuation requests of the FC relay precharge side (FRP) ON/OFF - -
FC Negative Relay Drive Request Actuation requests of the FC relay negative side (FRG) ON/OFF - -
FC Positive Relay Drive Request Actuation requests of the FC relay positive side (FRB) ON/OFF - -
Radiator Rotary Valve Drive Position Operation opening angle of the FC cooling water temperature control valve Min.: 0%, Max.: 255% - 0%:
FC stack → Radiator passage is closed
100.00%:
FC stack → Radiator passage is opened
Target Radiator Rotary Valve Position Target opening angle of the FC cooling water temperature control valve Min.: 0%, Max.: 399.99% - 0%:
FC stack → Radiator passage is closed
100.00%:
FC stack → Radiator passage is opened
Radiator Rotary Valve Position Anticipated current opening angle of the FC cooling water temperature control valve Min.: 0%, Max.: 399.99% - 0%:
FC stack → Radiator passage is closed
100.00%:
FC stack → Radiator passage is opened
Air Pressure Regulating Valve Drive Position Operation opening angle of the air pressure regulating valve Min.: 0%, Max.: 255% - -
Air Shunt Valve Drive Position Operation opening angle of the air shunt valve Min.: 0%, Max.: 255% - -
Air Sealing Valve Drive Position Operation opening angle of the air sealing valve Min.: 0%, Max.: 255% - -
Tank Shut Valve 1 Drive Status Actuation requests to the tank shut valve of the No. 1 hydrogen tank assembly Open/Close Open:
Ignition switch ON (READY)
Close:
READY off
Requests are off during hydrogen leak inspection of vehicle control.
Tank Shut Valve 1 Status Tank shut valve actuation circuit condition of the No. 1 hydrogen tank assembly Open/Close Open:
Ignition switch ON (READY)
Close:
READY off
-
Tank Shut Valve 2 Drive Status Actuation requests to the tank shut valve of the No. 2 hydrogen tank assembly Open/Close Open:
Ignition switch ON (READY)
Close:
READY off
Requests are off during hydrogen leak inspection of vehicle control.
Tank Shut Valve 2 Status Tank shut valve actuation circuit condition of the No. 2 hydrogen tank assembly Open/Close Open:
Ignition switch ON (READY)
Close:
READY off
-
Tank Shut Valve 3 Drive Status Actuation requests to the tank shut valve of the No. 3 hydrogen tank assembly Open/Close Open:
Ignition switch ON (READY)
Close:
READY off
Requests are off during hydrogen leak inspection of vehicle control.
Tank Shut Valve 3 Status Tank shut valve actuation circuit condition of the No. 3 hydrogen tank assembly Open/Close Open:
Ignition switch ON (READY)
Close:
READY off
-
Tank Shut Valve Power Relay Drive Status H2 SHUT VLV relay actuation circuit condition ON/OFF ON:
Ignition switch ON
OFF:
Ignition switch off
-
Tank Shut Valve Power Relay Drive Signal Status Actuation requests to the H2 SHUT VLV relay ON/OFF ON:
Ignition switch ON
OFF:
Ignition switch off
The EV control ECU switches the H2 SHUT VLV relay on or off.
Hydrogen Pump Drive Speed Drive speed of the hydrogen pump Min.: 0 rpm, Max.: 65535 rpm - -
Hydrogen Pump Speed Measured motor speed of the hydrogen pump Min.: -8192 rpm, Max.: 8191.75 rpm 500.00 to 700.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working)
-
Target Hydrogen Pump Speed Target motor speed of the hydrogen pump Min.: -8192 rpm, Max.: 8191.75 rpm - -
FC Coolant Pump Drive Speed Drive speed of the FC cooling water pump assembly Min.: 0 rpm, Max.: 65535 rpm - -
FC Coolant Pump Speed Measured motor speed of the FC cooling water pump assembly Min.: 0 rpm, Max.: 65535 rpm 0 to 1000.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working)
Compare a displayed value with the "Target FC Coolant Pump Speed" value.
Target FC Coolant Pump Speed Target motor speed of the FC cooling water pump assembly Min.: 0 rpm, Max.: 65535 rpm - -
Radiator Fan 1 Drive Voltage Requested voltage to the cooling fan controller with motor Min.: 0 V, Max.: 25.5 V 0 V:
Cooling fan stopped
-
FC Air Compressor Motor Drive Speed Drive speed of the FC air compressor with motor assembly Min.: 0 rpm, Max.: 65535 rpm - -
FC Air Compressor Motor Speed Motor speed of the FC air compressor with motor assembly Min.: -32768 rpm, Max.: 32767 rpm - -
FC Air Compressor Motor Speed (Measured Value) Measured motor speed of the FC air compressor with motor assembly Min.: 0 rpm, Max.: 65535 rpm 0 to 1000.00 rpm:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
Target FC Air Compressor Motor Speed Target motor speed of the FC air compressor with motor assembly Min.: -32768 rpm, Max.: 32767 rpm - -
Starting Status (An Side) Starting status (anode side) Initial State / DC/DC Preparing / Pressurization Preparing / Stack Pressurization / Leak Check/Hydrogen Substitution / Complete - For checking changes in status of the FC system starting at ambient temperatures
Stopping Status (An Side) Stopping status (anode side) Initial State / Pressurization / Drainage / Gas-Liquid Separator Drainage / Partial Pressure/Decompression / Leak Check / Sensor Learning / Isolation Fault Parts Detection / Stopping / Complete - For checking changes in status of the FC system stopping at ambient temperatures
Starting Status (Ca Side) Starting status (cathode side) Initial State / DC/DC Preparing / An Side Preparing / EV Standby / Generation / Diluted State / Complete - For checking changes in status of the FC system starting at ambient temperatures
Stopping Status (Ca Side) Stopping status (cathode side) Initial State / Drainage / Sealing / Oxygen Consumption / Dilution / Isolation Fault Parts Detection / Stopping / Complete - For checking changes in status of the FC system stopping at ambient temperatures
Restart Execute Time Time elapsed after turning ignition switch off while driving and then restarting while still driving Min.: 0 ms, Max.: 65535 ms - -
Emergency Shutdown Signal (FC) FCSD terminal status of the EV control ECU ON/OFF OFF:
Ignition switch ON (READY)
-
FC Emergency Shutdown Signal Shut down signal to the FC control ECU ON/OFF OFF:
Ignition switch ON (READY)
-
FC Start Request Displays the FC system start command status ON/OFF - -
FC Stop Request Displays the FC system stop command status None / Normal Stop / Sudden Stop / Emergency Stop - -
Master Warning Lighting Request (FC) Master warning light illumination request signal from the FC control ECU ON/OFF OFF:
Ignition switch ON (READY)
-
FC Work Mode Mode of the FC stack operation Stop / Finishing / Startup / Working Stop:
Ignition switch ON
Stop
·

FC stack has stopped operating

·

The vehicle is in READY OFF mode


Startup
·

The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied), which are located after the tank shut valve, are pressurized by supplying compressed hydrogen gas from the hydrogen tank assembly. During pressurization, high-range and low-range hydrogen pressures are monitored.


Working
·

FC stack is ready to generate power.


Finishing
·

The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied) is depressurized. During depressurization, the high-range and mid-range pressures in the hydrogen supply system are monitored.


FC System Status FC system status Stop / Finishing / Startup / Working Stop:
Ignition switch ON
Stop
·

FC stack has stopped operating

·

The vehicle is in READY OFF mode


Startup
·

The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied), which are located after the tank shut valve, are pressurized by supplying compressed hydrogen gas from the hydrogen tank assembly. During pressurization, high-range and low-range hydrogen pressures are monitored.


Working
·

FC stack is ready to generate power.


Finishing
·

The components and pipes employed by the hydrogen supply system (where high-range and mid-range pressures are applied) and the hydrogen circulation system (where low-range pressures are applied) is depressurized. During depressurization, the high-range and mid-range pressures in the hydrogen supply system are monitored.


FC Power Generation Status Mode of the FC stack power generation Normal / Intermittent / Quick Warmup Normal:
Normal FC system control (including FC shutdown)
Intermittent:
FC intermittent operation
Quick Warmup:
FC stack quick warmup
-
Target FC Current (Filtered Value) Command value of the FC stack power generation current Min.: 0 A, Max.: 655.35 A - -
FC Current Measured power generation current of the FC stack Min.: -3276.8 A, Max.: 3276.7 A 0 to 50.00 A:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working), A/C off, Electrical load off
-
FC Current (Filtered Value) Filtered value of the FC stack power generation current Min.: 0 A, Max.: 655.35 A - -
Maximum Available FC Current Maximum possible power generation current value of the FC stack Min.: 0 A, Max.: 655.35 A - -
FC Current Limit Value (Temperature High) FC stack power generation current limit value at high temperatures Min.: 0 A, Max.: 655.35 A - -
FC Current Limit Value (Hydrogen Stoichiometric Ratio) FC stack power generation current limit value due to hydrogen concentration Min.: 0 A, Max.: 655.35 A - -
FC Current Limit Value (Auxiliary Battery Driving) FC stack power generation current limit value due to auxiliary driving Min.: 0 A, Max.: 655.35 A - -
FC Current Limit Value (Cell Monitor) FC stack power generation current limit value according to the cell monitor Min.: 0 A, Max.: 655.35 A - -
FC Voltage (Filtered Value) Measured power generation voltage filtered value of the FC stack Min.: 0 V, Max.: 655.35 V 0 V:
Ignition switch ON
0 to 330.0 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
FC Output Power Limit Value (FC Air Compressor Shutdown) FC stack output limit value due to FC air compressor shutdown Min.: -327.68 kW, Max.: 327.67 kW Output is limited due to FC air compressor shutdown: 0 kW -
FC Output Power Limit Value (Hydrogen Gas Level Low) FC stack output limit value due to low hydrogen level Min.: -327.68 kW, Max.: 327.67 kW Output is limited due to low hydrogen level: 0.5 kW or less -
FC Output Power Limit Value (FC Intermittent Operation by Hydrogen Leak) FC stack output limit value during FC intermittent operation due to hydrogen leak Min.: -327.68 kW, Max.: 327.67 kW Output is limited during FC intermittent operation due to hydrogen leak: 0 kW -
FC Intermittent Operation FC stack power generation waiting state (including very small power generation) ON/OFF ON:
FC intermittent operation
-
Target FC Temperature Target temperature of the FC stack Min.: -40°C (-40°F), Max.: 215.9°C (421°F) - -
Target FC Inlet Air Pressure Target air pressure of the FC stack inlet Min.: 0 kPa, Max.: 1441.77 kPa - -
FC Inlet Air Pressure (Filtered Value) Intake air pressure filtered value of the FC stack inlet Min.: 0 kPa, Max.: 1441.77 kPa Approximately 100.00 kPa(abs):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
FC Inlet Air Temperature (Filtered Value) Intake air temperature filtered value of the FC stack inlet Min.: -40°C (-40°F), Max.: 215.9°C (421°F) Approximately a range of a "Intake Air Temperature (Filtered Value)" to a "Intake Air Temperature (Filtered Value)" plus 20°C (68°F):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
FC Coolant Pump Initial Request FC cooling water pump inverter assembly initial request ON/OFF - -
FC Coolant Pump Main Power Supply Status FC cooling water pump inverter assembly main power supply status Normal / Low Voltage / Overvoltage / Abnormal Normal:
Ignition switch ON (READY)
-
FC Coolant Pump Output Status FC cooling water pump inverter assembly output status Normal / Circuit Short / Circuit Open / Current Abnormal Normal:
Ignition switch ON (READY)
-
FC Coolant Pump Load Status FC cooling water pump inverter assembly load status Normal / Inverter Output Voltage Saturation / Motor Current Limit / Soft Overcurrent / Input Overcurrent / Input Current Saturation Normal:
Ignition switch ON (READY)
-
FC Coolant Pump Over Temperature Status FC cooling water pump assembly overheating status Normal / Temperature Limit / Over Temperature / Thermistor Abnormal Normal:
Ignition switch ON (READY)
-
FC Coolant Pump STB Control Signal FC cooling water pump inverter assembly standby request signal ON/OFF - Standby request signal from the EV control ECU
FC Coolant Pump Inverter STB Status FC cooling water pump inverter assembly standby signal status ON/OFF - -
FC Coolant Pump LIN Communication Control FC cooling water pump inverter assembly LIN communication control ON/OFF - -
FC Coolant Pump Isolation Fault Detection Control FC cooling water pump inverter assembly current leakage detection control ON/OFF - -
Lost Communication with FC Coolant Pump Communication error with the FC cooling water pump inverter assembly ON/OFF - -
FC Coolant Pump CPU Abnormal FC cooling water pump inverter assembly CPU malfunction ON/OFF - -
FC Coolant Pump Start Fail FC cooling water pump inverter assembly start failure ON/OFF - -
FC Coolant Pump Consumption Power Measured power consumption of the FC cooling water pump assembly Min.: 0 W, Max.: 65535 W 100 W or less:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working)
The FC cooling water pump assembly power consumption increases in proportion to increases in the load of the pump.
FC Converter Status FC boost converter status Normal/Abnormal Normal:
Ignition switch ON (READY)
-
FC Converter Shutdown Request Shut down request to the FC boost control ECU ON/OFF - -
FC Converter Shutdown Status FC boost converter shutdown status ON/OFF - -
FC Converter Shutdown Signal FC boost converter shutdown signal ON/OFF - -
FC Air Compressor Gate Shutdown Request FC air compressor inverter shutdown request ON/OFF ON:
FC air compressor inverter shutdown request
OFF:
Normal
-
FC Air Compressor Shutdown Status FC air compressor inverter shutdown status ON/OFF ON:
FC air compressor inverter shutdown
OFF:
Normal
-
FC Air Compressor Consumption Power Measure power consumption of the FC air compressor with motor assembly Min.: 0 W, Max.: 65535 W - Measured power consumption of the FC air compressor with motor assembly
FC Air Compressor Temperature just after IG ON FC air compressor motor temperature soon after ignition switch ON Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
FC Air Compressor Maximum Temperature Maximum FC air compressor motor temperature after ignition switch turned to ON in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
FC Air Compressor Motor Operation Status FC air compressor motor operation status Shutdown / 3 Phase ON / Discharge / Insulation Resistance Measurement / Output Torque / Emergency Shutdown / Shutdown during Insulation Resistance Measurement / Drive - -
FC Air Compressor Motor Control Mode FC air compressor motor control mode Sine Wave / Overmodulation / Square Wave / Electrical Power Loss Reduction Mode - -
V Phase FC Air Compressor Motor Current FC air compressor motor phase V current value Min.: -3276.8 A, Max.: 3276.7 A - -
W Phase FC Air Compressor Motor Current FC air compressor motor phase W current value Min.: -3276.8 A, Max.: 3276.7 A - -
FC Air Compressor Motor Carrier Frequency FC air compressor motor carrier frequency 0.75 kHz / 1.25 kHz / 2.5 kHz / 3.75 kHz / 5 kHz / 10 kHz / Electrical Power Loss Reduction Mode - -
FC Air Compressor Motor Temperature FC air compressor motor temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) 25°C (77°F):
Vehicle left for 1 day at an ambient temperature of 25°C (77°F)
25 to 120°C (77 to 248°F):
While driving at an ambient temperature of 25°C (77°F)
AMT terminal signal
FC Air Compressor Motor Temperature (Filtered Value) FC air compressor motor temperature filtered value Min.: -40°C (-40°F), Max.: 215.9°C (421°F) - -
FC Air Compressor Motor Torque Estimate Value FC air compressor motor torque estimate value Min.: -4096 Nm, Max.: 4095.87 Nm - -
FC Air Compressor Inverter Shutdown Status FC air compressor inverter shutdown ON/OFF ON:
FC air compressor inverter shutdown
OFF:
Normal
-
FC Air Compressor Inverter Stop FC air compressor inverter stopped ON/OFF ON:
FC air compressor inverter stopped
OFF:
Normal
-
FC Air Compressor Inverter Maximum Temperature Maximum FC air compressor inverter temperature after ignition switch turned to ON in current trip Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
FC Air Compressor Inverter Overcurrent Overcurrent detection into FC air compressor inverter ON/OFF ON:
Overcurrent is detected into FC air compressor inverter
OFF:
Normal
-
FC Air Compressor Inverter Temperature FC air compressor inverter temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) 15 to 35°C (59 to 95°F):
Vehicle left for 1 day at an ambient temperature of 25°C (77°F)
25 to 120°C (77 to 248°F):
While driving at an ambient temperature of 25°C (77°F)
-
FC Air Compressor Inverter Temperature (Filtered Value) FC air compressor inverter temperature filtered value Min.: -40°C (-40°F), Max.: 215.9°C (421°F) - -
FC Air Compressor Inverter Temperature just after IG ON FC air compressor inverter temperature soon after ignition switch ON Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
FC Stack Cell Average Minimum Voltage Lowest average voltage that is obtained by measuring 2 cell channels among the FC stack 330 cells Min.: -40 V, Max.: 39.99 V 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated))
-
FC Stack Cell Minimum Voltage Lowest voltage that is obtained by measuring 1 cell channels among the FC stack 330 cells Min.: -40 V, Max.: 39.99 V 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated))
-
Estimate FC Stack Cell Minimum Voltage 1 Lowest estimate voltage that is obtained by measuring 1 cell channels among the FC stack 330 cells Min.: -40 V, Max.: 39.99 V 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated))
-
Estimate FC Stack Cell Minimum Voltage 2 Lowest estimate voltage that is obtained by measuring 2 cell channels among the FC stack 330 cells Min.: -40 V, Max.: 39.99 V 0 to 1.00 V:
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF (i.e. power is being generated))
-
FC Stack Cell Average Minimum Voltage ch Channel number of the lowest average voltage of measured 2 cell channels among the FC stack 330 cells Min.: 0 ch, Max.: 65535 ch - -
FC Stack Cell Minimum Voltage ch Channel number of the lowest voltage of measured 1 cell channels among the FC stack 330 cells Min.: 0 ch, Max.: 65535 ch - -
FC Stack Outlet Coolant Temperature Sensor Voltage Output voltage of the coolant temperature sensor of the FC stack outlet Min.: 0 V, Max.: 4.99 V - If the "FC Stack Outlet Coolant Temperature Sensor Voltage" is more than 4.90 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit.
FC Stack Outlet Coolant Temperature (Filtered Value) Coolant temperature of the FC stack outlet Min.: -40°C (-40°F), Max.: 215.9°C (421°F) 50°C (122°F) to 85°C (185°F):
After warming up
-
FC Stack Impedance Impedance (resistance) of the FC stack Min.: 0 ohm, Max.: 65.535 ohm Approximately from 0.05 to 0.30 ohm:
Vehicle stationary with ignition switch ON (READY)
-
Maximum Impedance ch FC stack maximum impedance (resistance) channel number Min.: 0 ch, Max.: 255 ch - -
Maximum Impedance Norm Maximum impedance (resistance) measured at the FC stack channel Min.: 0 mohm, Max.: 927.77 mohm - -
Impedance Update Counter FC stack impedance (resistance) update time Min.: 0 ms, Max.: 25500 ms - -
FC Water Release Switch FC water release switch condition ON/OFF ON:
FC water release switch being pushed and held
-
FC Precharge Relay Request FC relay precharge side (FRP) activation request status ON/OFF - -
FC Negative Relay Request FC relay negative side (FRG) activation request status ON/OFF - -
FC Positive Relay Request FC relay positive side (FRB) activation request status ON/OFF - -
FC Precharge Relay Control Status FC relay precharge side (FRP) request status ON/OFF - -
FC Precharge Relay Status FC relay precharge side (FRP) operation status ON/OFF - -
FC Positive Relay Drive Signal Voltage FC relay positive side (FRB) drive signal voltage Min.: 0 V, Max.: 4.99 V - -
FC Positive Relay Drive Status FC relay positive side (FRB) operation status Shutdown / Inrush / Keep - -
FC Negative Relay Drive Signal Voltage FC relay negative side (FRG) drive signal voltage Min.: 0 V, Max.: 4.99 V - -
FC Negative Relay Drive Status FC relay negative side (FRG) operation status Shutdown / Inrush / Keep - -
FC Interlock Switch FC interlock switch condition ON/OFF ON: The FC converter power outlet cable connector connected to the FC converter assembly is disconnected when the ignition switch is turned to ON -
FC Inter Cooler Outlet Temperature Sensor Voltage Output voltage of the FC stack inlet air temperature sensor Min.: 0 V, Max.: 4.99 V - -
FC Inter Cooler Outlet Temperature FC stack inlet air temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) Approximately a range of a "Intake Air Temperature (Filtered Value)" to a "Intake Air Temperature (Filtered Value)" plus 20°C (68°F):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
FC Inter Cooler Outlet Pressure Sensor Voltage Output voltage of the FC stack inlet air temperature sensor Min.: 0 V, Max.: 4.99 V - -
FC Inter Cooler Outlet Pressure FC stack inlet air pressure Min.: -327.68 kPa, Max.: 327.57 kPa Approximately 100.00 kPa(abs):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
Hydrogen Filling (FC) Hydrogen filling status ON/OFF ON: Hydrogen filling -
Hydrogen Filling Control Module Power Supply Relay Drive Signal HF-B relay actuation signal ON/OFF ON: Ignition switch ON -
Target Air Pressure Regulating Valve Position Target opening angle of the air pressure regulating valve Min.: -250%, Max.: 249.99% - -
Air Pressure Regulating Valve Position Air pressure regulating valve position Min.: -250%, Max.: 249.99% - -
Target Air Shunt Valve Position Target opening angle of the air shunt valve Min.: -250%, Max.: 249.99% - -
Air Shunt Valve Position Air shunt valve position Min.: -250%, Max.: 249.99% - -
Target Air Sealing Valve Position Target opening angle of the air sealing valve Min.: -250%, Max.: 249.99% - -
Air Sealing Valve Position Air sealing valve position Min.: -250%, Max.: 249.99% - -
Hydrogen Pump Initial Request FC hydrogen pump inverter assembly initial request ON/OFF - -
Hydrogen Pump Main Power Supply Status FC hydrogen pump inverter assembly main power supply status Normal / Low Voltage / Overvoltage / Abnormal - -
Hydrogen Pump Output Status FC hydrogen pump inverter assembly output status Normal / Circuit Short / Circuit Open / Current Abnormal - -
Hydrogen Pump Load Status FC hydrogen pump inverter assembly load status Normal / Inverter Output Voltage Saturation / Motor Current Limit / Input Overcurrent / Input Current Saturation - -
Hydrogen Pump Inverter STB Status FC hydrogen pump inverter assembly standby signal status ON/OFF - -
Hydrogen Pump LIN Communication Control FC hydrogen pump inverter assembly LIN communication control ON/OFF - -
Hydrogen Pump Isolation Fault Detection Control FC hydrogen pump inverter assembly current leakage detection control ON/OFF - -
Hydrogen Pump CPU Abnormal FC hydrogen pump inverter assembly CPU malfunction ON/OFF - -
Hydrogen Pump Start Fail FC hydrogen pump inverter assembly start failure ON/OFF - -
Hydrogen Pump Inverter Over Temperature Status FC hydrogen pump inverter assembly overheating status Normal / Temperature Limit / Over Temperature / Thermistor Abnormal - -
Hydrogen Pump STB Control Signal FC hydrogen pump inverter assembly standby request signal ON/OFF - Standby request signal from the EV control ECU
Hydrogen Pump Motor Temperature Sensor Voltage Output voltage of the hydrogen pump motor temperature sensor Min.: 0 V, Max.: 4.99 V - If the "Hydrogen Pump Motor Temperature Sensor Voltage" is more than 4.95 V or less than 0.05 V, it is suspected that an open or short has occurred in the sensor circuit.
Hydrogen Pump Motor Temperature (Filtered Value) Hydrogen pump motor measured temperature filtered value Min.: -40°C (-40°F), Max.: 215.9°C (421°F) A range of from an ambient temperature to an ambient temperature plus 40°C (104°F):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
Hydrogen Injector Injection Number The number of fuel injector assemblies that have to operate Min.: 0, Max.: 255 - -
Hydrogen Injector 1 Injection Period Injection period of the No. 1 fuel injector assembly Min.: 0 μs, Max.: 65535 μs - -
Hydrogen Injector 2 Injection Period Injection period of the No. 2 fuel injector assembly Min.: 0 μs, Max.: 65535 μs - -
Hydrogen Injector 3 Injection Period Injection period of the No. 3 fuel injector assembly Min.: 0 μs, Max.: 65535 μs - -
Hydrogen Intake Pressure Sensor Voltage Output voltage of the hydrogen tank pressure sensor (for inlet side) Min.: 0 V, Max.: 4.99 V - If the "Hydrogen Intake Pressure Sensor Voltage" is more than 4.95 V or less than 0.55 V, it is suspected that an open or short has occurred in the sensor circuit.
Hydrogen Intake Pressure Sensor Value Pressure of the hydrogen tank pressure sensor (for inlet side) Min.: -200 MPa, Max.: 199.99 MPa Hydrogen filling value:
Varying depending on the filling. Check valve is provided. Filling pressure varies when the lines (pipes) are pressurized by filling hydrogen gas.
While filling hydrogen, variations in the filling pressure can be checked when the ignition switch is turned to ON
Target Low-Range Hydrogen Pressure Target pressures in the low-range hydrogen pressure system components Min.: -720.896 kPa, Max.: 720.874 kPa 110 to 280 kPa(abs):
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
High-Range Hydrogen Pressure (Filtered Value) Internal pressure filtered values of the high-range hydrogen pressure system components Min.: 0 kPa, Max.: 655350 kPa 1000 to 87500 kPa(abs):
Vehicle stationary with ignition switch ON (READY)
This represents a pressure between the tank shut valve and the hydrogen supply regulator assembly
Medium-Range Hydrogen Pressure (Filtered Value) Internal pressure filtered values of the medium-range hydrogen pressure system components Min.: 0 kPa, Max.: 65535 kPa 1000 to 1600 kPa(abs):
Vehicle stationary with ignition switch ON (READY)
-
Low-Range Hydrogen Pressure (Filtered Value) Internal pressure filtered values of the low-range hydrogen pressure system components Min.: -720.896 kPa, Max.: 720.874 kPa "Atmospheric pressure plus 10 kPa" to "280 kPa(abs)":
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
Hydrogen Detector (Motor Room) Frequency Output frequency of the hydrogen detector (for front compartment side) Min.: 0 kHz, Max.: 65.535 kHz - Hydrogen detector output frequency is less than 0.75 kHz, it is suspected that an open or short has occurred in the sensor circuit.
Motor Room Hydrogen Density Hydrogen concentration detected by the hydrogen detector (for front compartment side) Min.: 0%, Max.: 399.99% 0.10% or less:
Vehicle stationary with ignition switch ON (READY)
-
Hydrogen Detector 1 Frequency Output frequency of the hydrogen detector (for hydrogen tank 1, 2 side) Min.: 0 kHz, Max.: 65.535 kHz - Hydrogen detector output frequency is less than 0.75 kHz, it is suspected that an open or short has occurred in the sensor circuit.
Tank Area 1 Hydrogen Density Hydrogen concentration detected by the hydrogen detector (for hydrogen tank 1, 2 side) Min.: 0%, Max.: 399.99% 0.10% or less:
Vehicle stationary with ignition switch ON (READY)
-
Hydrogen Detector 2 Frequency Output frequency of the hydrogen detector (for hydrogen tank 3 side) Min.: 0 kHz, Max.: 65.535 kHz - Hydrogen detector output frequency is less than 0.75 kHz, it is suspected that an open or short has occurred in the sensor circuit.
Tank Area 2 Hydrogen Density Hydrogen concentration detected by the hydrogen detector (for hydrogen tank 3 side) Min.: 0%, Max.: 399.99% 0.10% or less:
Vehicle stationary with ignition switch ON (READY)
-
Hydrogen Gas Empty Hydrogen tank assembly has been depleted ON/OFF OFF:
Ignition switch ON (READY)
Tank depletion is measured through the medium-range hydrogen pressure.
Purge Amount Estimate Value Purge amount estimated value due to the exhaust drainage valve opening Min.: 0 L, Max.: 3999.38 L - -
Hydrogen Gas Level Remaining amount of the hydrogen inside the hydrogen tank assembly Min.: 0%, Max.: 127.5% - The remaining amount of the hydrogen inside the tank is calculated based on the value from the hydrogen tank pressure sensor (for outlet side)
Exhaust Drainage Valve Open requests to the exhaust drainage valve Open/Close Open:
Requesting the exhaust drainage valve to open
-
Water Heating Heater Consumption Power Electric heater sub-assembly power consumption Min.: 0 kW, Max.: 12.75 kW - -
Water Heating Heater Drive Request Electric heater sub-assembly drive request ON/OFF - -
Water Heating Heater STB Status Electric heater sub-assembly standby status None / OFF / ON / Clogged - -
Water Heating Heater Drive Signal Status Electric heater sub-assembly drive signal status ON/OFF - -
Water Heating Heater Drive Power Electric heater sub-assembly drive power Min.: 0 W, Max.: 65535 W - -
Hydrogen Tank 1 Temperature at Hydrogen Filling Hydrogen temperature inside the No. 1 hydrogen tank assembly during hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 1 Temperature (Filtered Value) Hydrogen temperature filtered value in the No. 1 hydrogen tank assembly Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) Almost same as ambient temperatures:
8 hours have elapsed after the ignition switch is turned off
-
Hydrogen Tank 1 Temperature Sensor Voltage Output voltage of the hydrogen temperature sensor in the No. 1 hydrogen tank assembly Min.: 0 V, Max.: 4.99 V - If the hydrogen temperature sensor is more than 4.9 V or less than 0.1 V, it is suspected that an open or short has occurred in the sensor circuit.
Hydrogen Tank 1 Temperature (1 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 1 hydrogen tank assembly 1 second prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 1 Temperature (2 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 1 hydrogen tank assembly 2 seconds prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 1 Temperature (3 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 1 hydrogen tank assembly 3 seconds prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 1 Temperature at Hydrogen Filling Abort Hydrogen temperature inside the No. 1 hydrogen tank assembly when hydrogen refilling stopped Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 2 Temperature at Hydrogen Filling Hydrogen temperature inside the No. 2 hydrogen tank assembly during hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 2 Temperature (Filtered Value) Hydrogen temperature filtered value in the No. 2 hydrogen tank assembly Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) Almost same as ambient temperatures:
8 hours have elapsed after the ignition switch is turned off
-
Hydrogen Tank 2 Temperature Sensor Voltage Output voltage of the hydrogen temperature sensor in the No. 2 hydrogen tank assembly Min.: 0 V, Max.: 4.99 V - If the hydrogen temperature sensor is more than 4.9 V or less than 0.1 V, it is suspected that an open or short has occurred in the sensor circuit.
Hydrogen Tank 2 Temperature (1 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 2 hydrogen tank assembly 1 second prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 2 Temperature (2 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 2 hydrogen tank assembly 2 seconds prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 2 Temperature (3 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 2 hydrogen tank assembly 3 seconds prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 2 Temperature at Hydrogen Filling Abort Hydrogen temperature inside the No. 2 hydrogen tank assembly when hydrogen refilling stopped Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 3 Temperature at Hydrogen Filling Hydrogen temperature inside the No. 3 hydrogen tank assembly during hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 3 Temperature (Filtered Value) Hydrogen temperature filtered value in the No. 3 hydrogen tank assembly Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) Almost same as ambient temperatures:
8 hours have elapsed after the ignition switch is turned off
-
Hydrogen Tank 3 Temperature Sensor Voltage Output voltage of the hydrogen temperature sensor in the No. 3 hydrogen tank assembly Min.: 0 V, Max.: 4.99 V - If the hydrogen temperature sensor is more than 4.9 V or less than 0.1 V, it is suspected that an open or short has occurred in the sensor circuit.
Hydrogen Tank 3 Temperature (1 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 3 hydrogen tank assembly 1 second prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 3 Temperature (2 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 3 hydrogen tank assembly 2 seconds prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 3 Temperature (3 sec before Hydrogen Filling Abort) Hydrogen temperature inside the No. 3 hydrogen tank assembly 3 seconds prior to stopping hydrogen filling Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Tank 3 Temperature at Hydrogen Filling Abort Hydrogen temperature inside the No. 3 hydrogen tank assembly when hydrogen refilling stopped Min.: -327.68°C (-557.82°F), Max.: 327.67°C (621.80°F) - -
Hydrogen Intake Pressure (1 sec before Hydrogen Filling Abort) Hydrogen tank pressure sensor (for inlet side) 1 second prior to stopping hydrogen filling Min.: 0 kPa, Max.: 655350 kPa - -
Hydrogen Intake Pressure (2 sec before Hydrogen Filling Abort) Hydrogen tank pressure sensor (for inlet side) 2 seconds prior to stopping hydrogen filling Min.: 0 kPa, Max.: 655350 kPa - -
Hydrogen Intake Pressure (3 sec before Hydrogen Filling Abort) Hydrogen tank pressure sensor (for inlet side) 3 seconds prior to stopping hydrogen filling Min.: 0 kPa, Max.: 655350 kPa - -
Hydrogen Intake Pressure at Hydrogen Filling Abort Hydrogen tank pressure sensor (for inlet side) when hydrogen refilling stopped Min.: 0 kPa, Max.: 655350 kPa - -
Hydrogen Intake Pressure at Hydrogen Filling Hydrogen tank pressure sensor (for inlet side) during hydrogen filling Min.: 0 kPa, Max.: 655350 kPa - -
Hydrogen Tank SOC (1 sec before Hydrogen Filling Abort) Hydrogen tank assembly hydrogen filling ratio 1 second prior to stopping hydrogen filling Min.: 0%, Max.: 127.5% - -
Hydrogen Tank SOC (2 sec before Hydrogen Filling Abort) Hydrogen tank assembly hydrogen filling ratio 2 seconds prior to stopping hydrogen filling Min.: 0%, Max.: 127.5% - -
Hydrogen Tank SOC (3 sec before Hydrogen Filling Abort) Hydrogen tank assembly hydrogen filling ratio 3 seconds prior to stopping hydrogen filling Min.: 0%, Max.: 127.5% - -
Hydrogen Tank SOC at Hydrogen Filling Abort Hydrogen tank assembly hydrogen filling ratio when hydrogen refilling stopped Min.: 0%, Max.: 127.5% - -
Main Radiator Fan Voltage Cooling fan controller with motor drive voltage Min.: 0 V, Max.: 25.5 V - -
Main Radiator Fan Control Duty Actuation request duty of the cooling fan controller with motor Min.: -200%, Max.: 199.99% - -
Radiator Outlet Coolant Temperature Sensor Voltage Output voltage of the water temperature sensor (for radiator outlet side) Min.: 0 V, Max.: 4.99 V - If the "Radiator Outlet Coolant temperature Sensor Voltage" is more than 4.90 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit, or the FC system operated in a FC stack coolant temperature was below -30°C (-22°F) or over 120°C (248°F) (output limitation did not be activated).
Radiator Outlet Coolant Temperature (Filtered Value) Coolant temperature filtered value of the radiator outlet Min.: -40°C (-40°F), Max.: 215.9°C (421°F) 50°C (122°F) to 85°C (185°F):
After warming up
-
FCV System Status FCV system status Stop / Preparing / Startup / Working / Finishing / Stopping / Reboot Preparing - -
FCDC Permission Current FC boost converter permissible current value Min.: -3276.8 A, Max.: 3276.7 A - -
FCDC Input Voltage FC boost converter input voltage sensor value Min.: 0 V, Max.: 6553.5 V 0 to 330 V:
Ignition switch ON (READY)
Value of the FVL sensor located inside the FC boost converter
FCDC Output Voltage FC boost converter output voltage sensor value Min.: 0 V, Max.: 6553.5 V 0 to 650 V:
Ignition switch ON (READY)
Value of the FVH sensor located inside the FC boost converter
Master Warning Lighting Request (FCDC) Master warning light illumination request signal from the FC boost control ECU ON/OFF OFF:
Ignition switch ON (READY)
-
FCDC Fail Signal Fail signal from the FC boost control ECU ON/OFF - -
Fail Safe Request Fail safe request from the FC boost control ECU No Fail Safe / Fail Safe1 / Fail Safe2 / Fail Safe3 / Fail Safe4 - -
Fail Safe Status (FCDC CAN Communication Status) Fail safe status according to CAN communication status of the FC boost control ECU ON/OFF OFF:
Ignition switch ON (READY)
-
Communication Error from Cell Monitor to FCDC Communication error from the cell monitor to the FC boost control ECU ON/OFF OFF:
Ignition switch ON (READY)
-
Cell Monitor AD Abnormal Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor ROM Abnormal Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor RAM Abnormal Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor Abnormal 1 Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor Abnormal 2 Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor Abnormal 1 (First Out) Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor Abnormal 2 (First Out) Malfunctions of the cell monitor ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor Power Supply Voltage Low Malfunctions of the cell monitor or auxiliary battery ON/OFF OFF:
Conditions other than malfunction
-
Cell Monitor Power Supply Voltage Power supply voltage of the cell monitor Min.: 0 V, Max.: 4.99 V - -
Ion Exchanger Maintenance Distance Ion exchanger maintenance distance Min.: 0 [km] (0 [mile]), Max.: 6553500 [km] (472345 [mile]) - -
Water Vapor Dilution Control Status Water vapor dilution control status Inactive/Active Active:
Water vapor dilution controlled
Inactive:
Normal
-
Water Vapor Dilution Control Temperature Water vapor dilution control temperature Min.: -64°C (-83.2°F), Max.: 63.5°C (146.3°F) - -
Conductivity Reduction Complete Conductivity reduction complete ON/OFF - -
Number of Filling Number of filling Min.: 0, Max.: 65535 - -


ACTIVE TEST (EV)


Using the GTS to perform Active Tests allows actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

NOTICE:

After performing the Active Test, turn the ignition switch off before proceeding to the next step.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / EV / Active Test.


e.

According to the display on the GTS perform the appropriate Active Test.

Powertrain > EV > Active Test
Tester Display Measurement Item Restrict Condition Diagnostic Note
Control the Radiator Fan 1 Drive the cooling fan controller with motor Ignition switch ON
·

Control Range

0.1 to 13.7 V


·

Visually check or listen to sound for the radiator fan operation.


Control the Select Hydrogen Injector Injectors can be selected to operate (but the valve cannot be opened forcefully)*1
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

"Low-Range Hydrogen Pressure (Filtered Value)" in the Data List shows a value less than 270 kPa(abs)

·

Hydrogen secondary pressure sensor is not abnormal

·

Number of injecting fuel injector assemblies is 1


·

Control Range

#1/#2/#3


·

Related Data List

-

Hydrogen Injector 1 Injection Period

-

Hydrogen Injector 2 Injection Period

-

Hydrogen Injector 3 Injection Period

-

Low-Range Hydrogen Pressure (Filtered Value)


·

Valve opening of a fuel injector assembly can be identified by an increase in the "Low-Range Hydrogen Pressure (Filtered Value)" when an injection request flag has turned ON.

·

By actuating the injectors from 1 to 3 in sequence, increases in the "Low-Range Hydrogen Pressure (Filtered Value)" values during injection can be compared

·

See waveform 1


Activate the Exhaust Drainage Valve Operation checks for the exhaust drainage valve
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent


·

Valve opens for 1 second after request

Related Data List
-

Exhaust Drainage Valve



Activate the FC Water Drainage Forced drain
·

Ignition switch ON (READY)

·

Shift state in park (P)


·

By turning the ignition switch off after selection, if the FC is cool it warms up, and then forced drain can be performed in the stack.


FC Stack Inspection Mode Switching to FC stack inspection mode
·

Ignition switch ON (READY)

·

Shift state in park (P)


·

Switching to FC stack inspection mode performs forced power generation of specified current (around 25 to 50 A) for approximately 6 minutes during idling.


Activate the FC Precharge Relay Operation checks for the FC relay precharge side (FRP)
·

Ignition switch ON

·

SMR (System Main Relay) is not connected

·

BATT Voltage is below 10 V


·

FC relay forced actuation is allowed for one side only

·

If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur.

Relating Data List items:
-

SMRB Status

-

SMRG Status

-

FCDC Input Voltage

-

FC Positive Relay Drive Request

-

FC Negative Relay Drive Request

-

FC Precharge Relay Drive Request



Activate the FC Negative Relay Operation checks for the FC relay negative side (FRG)
·

Ignition switch ON

·

SMR (System Main Relay) is not connected

·

BATT Voltage is below 10 V


·

FC relay forced actuation is allowed for one side only

·

If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur.

Relating Data List items:
-

SMRB Status

-

SMRG Status

-

FCDC Input Voltage

-

FC Positive Relay Drive Request

-

FC Negative Relay Drive Request

-

FC Precharge Relay Drive Request



Activate the FC Positive Relay Operation checks for the FC relay positive side (FRB)
·

Ignition switch ON

·

SMR (System Main Relay) is not connected

·

BATT Voltage is below 10 V


·

FC relay forced actuation is allowed for one side only

·

If the EV control ECU simultaneously receives actuation requests for both positive and negative sides, forced actuation will be disabled as damage to the relay could occur.

Relating Data List items:
-

SMRB Status

-

SMRG Status

-

FCDC Input Voltage

-

FC Positive Relay Drive Request

-

FC Negative Relay Drive Request

-

FC Precharge Relay Drive Request



Control the Radiator Rotary Valve Drive the FC cooling water temperature control valve to a requested opening angle
·

Shift state in park (P)

·

"FC Stack Outlet Coolant Temperature (Filtered Value)" in the Data List shows 10°C (50°F) to 78°C (172.4°F)


·

Control Range

1 to 100%

1%: FC stack → Radiator passage is closed

100%: FC stack → Radiator passage is opened


·

Related Data List

-

Target Radiator Rotary Valve Position

-

Radiator Outlet Coolant Temperature (Filtered Value)

-

FC Stack Outlet Coolant Temperature (Filtered Value)


·

For inspection instructions for the FC cooling water temperature control valve, refer to FC cooling water temperature control valve operation checks provided in the following page.


Control the Air Pressure Regulating Valve Drive the air pressure regulating valve to a requested opening angle
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

FC Air Compressor Motor Speed is 1800 rpm or less


·

Control Range

1 to 100%

1%: Air pressure regulating valve is closed

100%: Air pressure regulating valve is opened


·

Related Data List

-

Air Pressure Regulating Valve Drive Position

-

Target Air Pressure Regulating Valve Position

-

Air Pressure Regulating Valve Position



Control the Air Shunt Valve Drive the air shunt valve to a requested opening angle
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

FC Air Compressor Motor Speed is 2000 rpm or less


·

Control Range

1 to 100%

1%: Air shunt valve is closed

100%: Air shunt valve is opened


·

Related Data List

-

Air Shunt Valve Drive Position

-

Target Air Shunt Valve Position

-

Air Shunt Valve Position



Control the Air Sealing Valve Drive the air sealing valve to a requested opening angle
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

FC Air Compressor Motor Speed is 1800 rpm or less


·

Control Range

1 to 100%

1%: Air sealing valve is closed

100%: Air sealing valve is opened


·

Related Data List

-

Air Sealing Valve Drive Position

-

Target Air Sealing Valve Position

-

Air Sealing Valve Position



Activate the Tank Shut Valve 1 Operation checks for the tank shut valve 1
·

Ignition switch ON

·

No DTCs output for hydrogen primary pressure sensor, hydrogen tank temperature sensor or tank shut valve

·

The pressure of the hydrogen primary pressure sensor is higher than 800 kPa 5 seconds after the value opens

·

Hydrogen tank temperature is -45°C (-49°F) or higher

·

Detected hydrogen concentration is less than 1.2%


·

Control Range

Open/Close


·

Related Data List

-

Tank Shut Valve 1 Drive Status

-

Tank Shut Valve 1 Status

-

Tank Shut Valve Power Relay Drive Status

-

Tank Shut Valve Power Relay Drive Signal Status



Activate the Tank Shut Valve 2 Operation checks for the tank shut valve 2
·

Ignition switch ON

·

No DTCs output for hydrogen primary pressure sensor, hydrogen tank temperature sensor or tank shut valve

·

The pressure of the hydrogen primary pressure sensor is higher than 800 kPa 5 seconds after the value opens

·

Hydrogen tank temperature is -45°C (-49°F) or higher

·

Detected hydrogen concentration is less than 1.2%


·

Control Range

Open/Close


·

Related Data List

-

Tank Shut Valve 2 Drive Status

-

Tank Shut Valve 2 Status

-

Tank Shut Valve Power Relay Drive Status

-

Tank Shut Valve Power Relay Drive Signal Status



Activate the Tank Shut Valve 3 Operation checks for the tank shut valve 3
·

Ignition switch ON

·

No DTCs output for hydrogen primary pressure sensor, hydrogen tank temperature sensor or tank shut valve

·

The pressure of the hydrogen primary pressure sensor is higher than 800 kPa 5 seconds after the value opens

·

Hydrogen tank temperature is -45°C (-49°F) or higher

·

Detected hydrogen concentration is less than 1.2%


·

Control Range

Open/Close


·

Related Data List

-

Tank Shut Valve 3 Drive Status

-

Tank Shut Valve 3 Status

-

Tank Shut Valve Power Relay Drive Status

-

Tank Shut Valve Power Relay Drive Signal Status



Control the Hydrogen Pump Drive the hydrogen pump to a requested pump speed
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

For 60 seconds after an Active Test is requested


·

Control Range

600 to 6800 rpm


·

Related Data List

-

Hydrogen Pump Drive Speed

-

Hydrogen Pump Speed

-

Target Hydrogen Pump Speed


·

"Hydrogen Pump Speed" is normally within a "Target Hydrogen Pump Speed" +/-200 rpm (e.g. 2000 +/-200 rpm)

·

Operating sound can be heard from the operating hydrogen pump

·

See waveform 2


NOTICE:

If a pump speed continues decreasing, a DTC will be output due to lack of hydrogen.


Control the FC Coolant Pump Drive the FC cooling water pump assembly to a requested pump speed
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

For 60 seconds after an Active Test is requested


·

Control Range

500 to 5700 rpm


·

Related Data List

-

FC Coolant Pump Drive Speed

-

FC Coolant Pump Speed

-

Target FC Coolant Pump Speed

-

FC Stack Outlet Coolant Temperature (Filtered Value)

-

Radiator Outlet Coolant Temperature (Filtered Value)


·

"FC Coolant Pump Speed" is normally within a "Target Hydrogen Pump Speed" +/-100 rpm (e.g. 1500 +/-100 rpm)

·

Operating sound can be heard from the operating FC cooling water pump assembly

·

See waveform 3


NOTICE:

When decreasing a pump speed, pay attention to an increase in the "FC Stack Outlet Coolant Temperature (Filtered Value)".


Control the FC Air Compressor Drive the FC air compressor with motor assembly to a requested motor speed
·

Shift state in park (P)

·

Ignition switch ON (READY), "FC Work Mode" in the Data List shows Working

·

"FC Power Generation Status" in the Data List shows Normal or Intermittent

·

For 60 seconds after an Active Test is requested


·

Control Range

100 to 16700 rpm


·

Related Data List

-

FC Air Compressor Motor Drive Speed

-

FC Air Compressor Motor Speed

-

Target FC Air Compressor Motor Speed

-

FC Air Compressor Motor Speed (Measured Value)


·

"FC Air Compressor Motor Speed" is normally within a "Target FC Air Compressor Motor Speed" +/-200 rpm (e.g. 2000 +/-200 rpm)

·

Operating sound can be heard from the operating FC air compressor with motor assembly

·

If an air pressure increases too high due to forced continuous revolution increase in the compressor, it will be interpreted as a malfunction.

·

See waveform 4


NOTICE:

If a compressor speed continues decreasing, a DTC will be output due to lack of air.


Control the Water Heating Heater Drive the electric heater sub-assembly
·

Ignition switch ON (READY)

·

Shift state in park (P)

·

Electric heater sub-assembly is normal


·

Control Range

1 to 7000 W


·

The FC stack power generation current value can be increased by electric heater sub-assembly operation.


*1: Performing the Active Test "Control the Select Hydrogen Injector" does not forcefully activate injectors. The injector operation remains in normal control mode, and the Active Test is used to select any of the 3 injectors to operate.




FC cooling water temperature control valve operation checks
1.

Connect the GTS to the DLC3.

2.

Put the state in park (P), turn the ignition switch to ON (READY), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.

3.

Enter the following menus: Powertrain / EV / Active Test / Control the Radiator Rotary Valve

In addition, select "FC Stack Outlet Coolant Temperature (Filtered Value)" in the Data List.

4.

Using Active Tests, set the "Control the Radiator Rotary Valve" to 0%, and check the "FC Stack Outlet Coolant Temperature (Filtered Value)" by turning the air conditioning ON (Lo/Cool Max, maximum airflow) for 1 minute and then turning it OFF for 1 minute.

Result 1

The "FC Stack Outlet Coolant Temperature (Filtered Value)" does not change when the air conditioning is in ON or OFF.

HINT:

Turn on the air conditioning to actuate the radiator fan.




Using Active Tests, set the "Control the Radiator Rotary Valve" to 100%, and check the "FC Stack Outlet Coolant Temperature (Filtered Value)" by turning the air conditioning ON (Lo/Cool Max, maximum airflow) for 1 minute and then turning it OFF for 1 minute.

Result 2

The "FC Stack Outlet Coolant Temperature (Filtered Value)" changes by 2°C (3.6°F) or more (increases/decreases) when the air conditioning is turned ON or OFF.



Reference examples
A479992E02
0.948,6.042 1.344,6.5 false 2.177,5.927 2.323,5.427 false 4.01,6.156 4.542,5.469 false 3.073,7.271 3.083,7.146 false 4.146,2.448 4.865,1.885 true 0.094,0.063 1.5,0.49 1.406,0.427 10 false Target Radiator Rotary Valve Position 0.26,0.573 0.719,0.771 0.458,0.198 10 false 100% 0.406,1.156 0.75,1.354 0.344,0.198 10 false 0% 2.948,0.031 5.104,0.375 2.156,0.344 10 false "Control the Radiator Rotary Valve" Active Test: 1 → 100% 0.083,1.698 1.073,2.313 0.99,0.615 10 false Main Radiator Fan Voltage 0.385,2.365 0.813,2.583 0.427,0.219 10 false 9 V 1.823,1.708 2.792,2.031 0.969,0.323 10 false Air conditioning is turned ON 3.271,1.719 4.25,2.052 0.979,0.333 10 false Air conditioning is turned OFF 4.938,1.719 5.906,2.073 0.969,0.354 10 false Air conditioning is turned ON 0.073,3.313 1.865,3.948 1.792,0.635 10 false FC Stack Outlet Coolant Temperature (Filtered Value) 0.302,4.125 0.729,4.344 0.427,0.219 10 false 55°C 0.302,4.833 0.729,5.052 0.427,0.219 10 false 45°C 2.063,3.823 4.052,4.021 1.99,0.198 10 false No decrease in the temperature 5.073,3.823 6.813,4.031 1.74,0.208 10 false Decrease in the temperature 0.177,5.948 0.938,6.375 0.76,0.427 10 false FC Radiator Assembly 2.385,5.333 4.042,5.719 1.656,0.385 10 false Water Temperature Sensor (for Radiator Outlet Side) 4.604,5.354 5.719,5.792 1.115,0.438 10 false FC Cooling Water Pump Assembly 2.448,7.292 4.396,7.677 1.948,0.385 10 false FC Cooling Water Temperature Control Valve 4.719,7.313 6.021,7.594 1.302,0.281 10 false FC Stack Assembly 1.865,8.021 5.885,8.271 4.021,0.25 10 false : Flow of coolant (Target Radiator Rotary Valve Position = 100%) 1.865,8.375 5.875,8.563 4.01,0.188 10 false : Flow of coolant (Target Radiator Rotary Valve Position = 0%) 0.375,3.042 0.719,3.24 0.344,0.198 10 false 0 V

·

Check that the FC cooling water temperature control valve operation is normal by examining the changes in the "FC Stack Outlet Coolant Temperature (Filtered Value)" and inspection results 1 and 2 instructed above.


1. Control the Select Hydrogen Injector (Shift state is in park (P), ignition switch ON (READY), "FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
A476965E01
3.115,0.917 3.521,0.667 false 0.083,0.042 0.969,0.25 0.885,0.208 10 false Waveform 1: 0.083,0.365 2.521,0.604 2.438,0.24 10 false Hydrogen Injector 1 Injection Period 1.604,0.656 2.625,0.844 1.021,0.188 10 false Usual control 3.583,0.583 7.104,0.813 3.521,0.229 10 false Active Test is started, and injector 3 is selected 0.417,0.875 0.729,1.073 0.313,0.198 10 false ON 0.344,1.708 0.802,1.906 0.458,0.198 10 false OFF 0.417,2.667 0.729,2.865 0.313,0.198 10 false ON 0.344,3.49 0.802,3.688 0.458,0.198 10 false OFF 0.417,4.458 0.729,4.656 0.313,0.198 10 false ON 0.344,5.26 0.802,5.458 0.458,0.198 10 false OFF 0.094,2.292 2.677,2.49 2.583,0.198 10 false Hydrogen Injector 2 Injection Period 0.083,4.094 2.656,4.292 2.573,0.198 10 false Hydrogen Injector 3 Injection Period 0.094,5.802 3.406,6.167 3.313,0.365 10 false Low-Range Hydrogen Pressure (Filtered Value) 0.135,6.198 0.667,6.792 0.531,0.594 10 false 165 kPa(abs) 0.125,6.906 0.677,7.458 0.552,0.552 10 false 140 kPa(abs)

HINT:
·

During normal control, the injector performing injection switches in order from 1 to 2 then 3.

·

Using an Active Test of the injectors, select an injector to operate. Valve opening of an injector can be identified by an increase in the "Low-Range Hydrogen Pressure (Filtered Value)" when an injection request flag has turned ON.

·

By selecting the injectors from 1 to 3 in sequence, increases in the "Low-Range Hydrogen Pressure (Filtered Value)" values during injection can be compared. However, if the "Low-Range Hydrogen Pressure (Filtered Value)" increases or it is excessive when an injection request is inactive, it is suspected that any one of the injectors has stuck open.



2. Control the Hydrogen Pump (Shift state is in park (P), ignition switch ON (READY), "FC Work Mode" in the Data List shows Working)
A337124E02
4.573,0.854 4.917,0.188 true 5.406,0.833 5.969,0.594 true 0.073,0.052 1.167,0.25 1.094,0.198 10 false Waveform 2: 0.042,0.458 2.417,0.708 2.375,0.25 10 false Target Hydrogen Pump Speed 0.625,0.802 1.698,1 1.073,0.198 10 false 2000 rpm 0.844,1.729 1.458,1.927 0.615,0.198 10 false 0 rpm 2.302,0.667 3.354,0.854 1.052,0.188 10 false Usual control 4.958,0.083 7.021,0.26 2.063,0.177 10 false 2000 rpm is set in an Active Test 6.042,0.49 7.094,0.854 1.052,0.365 10 false 600 rpm is set in an Active Test 3.167,1.958 3.323,2.156 0.156,0.198 10 false A 5.063,1.958 5.219,2.156 0.156,0.198 10 false B 0.094,2.469 2.521,2.677 2.427,0.208 10 false Hydrogen Pump Speed 0.083,4.458 2.563,4.708 2.479,0.25 10 false Hydrogen Pump Drive Speed 0.844,3.74 1.458,3.938 0.615,0.198 10 false 0 rpm 0.625,2.813 1.698,3.01 1.073,0.198 10 false 2000 rpm 3.167,3.979 3.323,4.177 0.156,0.198 10 false A 3.167,5.99 3.323,6.188 0.156,0.198 10 false A 5.063,3.979 5.219,4.177 0.156,0.198 10 false B 5.063,5.99 5.219,6.188 0.156,0.198 10 false B 0.583,4.938 1.656,5.135 1.073,0.198 10 false 2000 rpm 0.802,5.771 1.417,5.969 0.615,0.198 10 false 0 rpm

GTS Display Measurement Item Reference Value
Control the Hydrogen Pump - ▲A ▲B
Target Hydrogen Pump Speed 900 rpm 2013 rpm
Hydrogen Pump Speed 863 rpm 2015 rpm
Hydrogen Pump Drive Speed 900 rpm 2013 rpm
Hydrogen Pump Output Status Normal Normal
Hydrogen Pump Load Status Normal Normal
Hydrogen Pump Inverter Over Temperature Status Normal Normal

HINT:
·

"Hydrogen Pump Speed" is normally within a "Target Hydrogen Pump Speed" +/-200 rpm.



3. Control the FC Coolant Pump (Shift state is in park (P), ignition switch ON (READY), "FC Work Mode" in the Data List shows Working)
A477017E01
2.281,1.271 2.698,0.854 true 0.063,0.042 1.125,0.229 1.063,0.188 10 false Waveform 3: 0.104,0.698 2.427,0.969 2.323,0.271 10 false Target FC Coolant Pump Speed 0.063,1.24 0.76,1.438 0.698,0.198 10 false 1500 rpm 0.281,2.135 0.896,2.333 0.615,0.198 10 false 0 rpm 1.052,1.083 2.104,1.26 1.052,0.177 10 false Usual control 2.729,0.688 4.865,0.906 2.135,0.219 10 false 1500 rpm is set in an Active Test 5.667,0.677 6.896,1.021 1.229,0.344 10 false 500 rpm is set in an Active Test 1.25,4.458 1.865,4.656 0.615,0.198 10 false A 3.156,2.396 3.771,2.594 0.615,0.198 10 false B 3.146,4.458 3.76,4.656 0.615,0.198 10 false B 0.271,4.229 0.885,4.427 0.615,0.198 10 false 0 rpm 0.073,3.375 0.771,3.573 0.698,0.198 10 false 1500 rpm 0.146,2.854 2.031,3.073 1.885,0.219 10 false FC Coolant Pump Speed 1.271,2.365 1.885,2.563 0.615,0.198 10 false A

GTS Display Measurement Item Reference Value
Control the FC Coolant Pump - ▲A ▲B
Target FC Coolant Pump Speed 825 rpm 1500 rpm
FC Coolant Pump Speed 831 rpm 1490 rpm
FC Coolant Pump Output Status Normal Normal
FC Coolant Pump Load Status Normal Normal
FC Coolant Pump Over Temperature Status Normal Normal

HINT:

"FC Coolant Pump Speed" is normally within a "Target FC Coolant Pump Speed" +/-100 rpm


4. Control the FC Air Compressor (Shift state is in park (P), ignition switch ON (READY), "FC Mode" in the Data List shows FC Working)
A337126E03
3.865,0.979 4.021,0.177 true 0.063,0.052 1.448,0.26 1.385,0.208 10 false Waveform 4: 0.073,0.458 2.969,0.729 2.896,0.271 10 false Target FC Air Compressor Motor Speed 0.094,2.458 2.594,2.802 2.5,0.344 10 false FC Air Compressor Motor Speed 2.042,0.885 2.927,1.094 0.885,0.208 10 false Usual control 0.083,0.906 0.823,1.115 0.74,0.208 10 false 2500 rpm 0.26,1.875 1,2.083 0.74,0.208 10 false 0 rpm 0.083,2.979 0.823,3.188 0.74,0.208 10 false 2500 rpm 0.302,3.938 1.042,4.146 0.74,0.208 10 false 0 rpm 6.073,0.531 7.115,0.875 1.042,0.344 10 false 500 rpm is set in an Active Test 4.073,0.052 6.292,0.417 2.219,0.365 10 false 2000 rpm is set in an Active Test (Increase the set speed gradually) 2.531,2.094 3.146,2.292 0.615,0.198 10 false A 2.542,4.188 3.156,4.385 0.615,0.198 10 false A 4.979,2.094 5.594,2.292 0.615,0.198 10 false B 4.99,4.188 5.604,4.385 0.615,0.198 10 false B

GTS Display Measurement Item Reference Value
Control the FC Air Compressor - ▲A ▲B
Target FC Air Compressor Motor Speed 590 rpm 2000 rpm
FC Air Compressor Motor Speed 575 rpm 1987 rpm

HINT:

"FC Air Compressor Motor Speed" is normally within a "Target FC Air Compressor Motor Speed" +/-200 rpm



Data List (FC)


NOTICE:
·

Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.

·

In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.



a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / FC / Data List.


e.

Check the results by referring to the following table.

Powertrain > FC > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Drive total distance Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) - -
Total Distance Traveled - Unit Unit of drive total distance km/mile - -
Smoothed Value of BATT Voltage Smoothed value of auxiliary battery voltage (BATT terminal) Min.: 0 V, Max.: 65.535 V Constant:
11 to 15 V
-
IG2 Status (Line) IGSW terminal state ON/OFF ON: Ignition switch ON -
IG2 Status (CAN/SIL) IGSW terminal status received from the EV control ECU ON/OFF ON: Ignition switch ON -
Ready Status State of system (READY) ON/OFF ON: Ignition switch ON (READY) -
FCG Relay Drive Request Actuation requests of the FRG relay ON/OFF ON: Ignition switch ON (READY) -
FCB Relay Drive Request Actuation requests of the FRB relay ON/OFF ON: Ignition switch ON (READY) -
High-Range Hydrogen Pressure Internal pressures of the high-range hydrogen pressure system components Min.: -200 MPa, Max.: 199.99 MPa 1.00 to 87.50 MPa:
Vehicle stationary with ignition switch ON (READY)
This represents a pressure between the tank shut valve and the hydrogen supply regulator assembly
Medium-Range Hydrogen Pressure Internal pressures of the medium-range hydrogen pressure system components Min.: -3276.8 kPa, Max.: 3276.7 kPa 1.00 to 1.60 MPa:
Vehicle stationary with ignition switch ON (READY)
-
Low-Range Hydrogen Pressure Internal pressures of the low-range hydrogen pressure system components Min.: 0 kPa, Max.: 633.35 kPa "Atmospheric pressure plus 10 kPa" to "280 kPa(abs)":
Vehicle stationary with ignition switch ON (READY) ("FC Work Mode" in the Data List shows Working, and "FC Intermittent Operation" shows OFF)
-
High-Range Hydrogen Pressure Sensor Voltage Output voltage of the hydrogen tank pressure sensor (for outlet side) Min.: 0 V, Max.: 4.99 V - If the "High-Range Hydrogen Pressure Sensor Voltage" is more than 4.65 V or less than 0.55 V, it is suspected that an open or short has occurred in the sensor circuit.
Medium-Range Hydrogen Pressure Sensor Voltage Output voltage of the hydrogen primary pressure sensor Min.: 0 V, Max.: 4.99 V - If the "Medium-Range Hydrogen Pressure Sensor Voltage" is more than 4.72 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit.
Low-Range Hydrogen Pressure Sensor Voltage Output voltage of the hydrogen secondary pressure sensor Min.: 0 V, Max.: 4.99 V - If the "Low-Range Hydrogen Pressure Sensor Voltage" is more than 4.72 V or less than 0.10 V, it is suspected that an open or short has occurred in the sensor circuit.
Exhaust Drainage Valve Status Actuation requests of the exhaust drainage valve Open/Close Open: Exhaust drainage valve operating -
Exhaust Drainage Valve Terminal Voltage Exhaust drainage valve voltage Min.: 0 V, Max.: 4.99 V - -
Air Valve Supply Voltage Power source voltage of the air valve Min.: 0 V, Max.: 79.99 V - -
Air Shunt Valve FAIL Signal Status (Open Side) Air shunt valve fail signal status (open side) High/Low - -
Air Sealing Valve FAIL Signal Status (Open Side) Air sealing valve fail signal status (open side) High/Low - -
Air Pressure Regulating Valve FAIL Signal Status (Open Side) Air pressure regulating valve fail signal status (open side) High/Low - -
Air Shunt Valve FAIL Signal Status (Close Side) Air shunt valve fail signal status (close side) High/Low - -
Air Sealing Valve FAIL Signal Status (Close Side) Air sealing valve fail signal status (close side) High/Low - -
Air Pressure Regulating Valve FAIL Signal Status (Close Side) Air pressure regulating valve fail signal status (close side) High/Low - -
Air Shunt Valve Operation Wait Status Air shunt valve operation confirmation status ON/OFF ON: Air shunt valve operation confirmation being performed -
Air Sealing Valve Operation Wait Status Air sealing valve operation confirmation status ON/OFF ON: Air sealing valve operation confirmation being performed -
Air Pressure Regulating Valve Operation Wait Status Air pressure regulating valve operation confirmation status ON/OFF ON: Air pressure regulating valve operation confirmation being performed -
Air Shunt Valve Circuit Open Confirmation Status Air shunt valve open circuit confirmation status ON/OFF ON: Air shunt valve open circuit confirmation being performed -
Air Sealing Valve Circuit Open Confirmation Status Air sealing valve open circuit confirmation status ON/OFF ON: Air sealing valve open circuit confirmation being performed -
Air Pressure Regulating Valve Circuit Open Confirmation Status Air pressure regulating valve open circuit confirmation status ON/OFF ON: Air pressure regulating valve open circuit confirmation being performed -
Air Shunt Valve DC Motor Current (Open Side) Air shunt valve DC motor current (open aside) Min.: -125 A, Max.: 124.99 A - -
Air Sealing Valve DC Motor Current (Open Side) Air sealing valve DC motor current (open aside) Min.: -125 A, Max.: 124.99 A - -
Air Pressure Regulating Valve DC Motor Current (Open Side) Air pressure regulating valve DC motor current (open aside) Min.: -125 A, Max.: 124.99 A - -
Air Shunt Valve Motor Duty Air shunt valve motor control duty Min.: 0%, Max.: 127.5% - -
Air Sealing Valve Motor Duty Air sealing valve motor control duty Min.: 0%, Max.: 127.5% - -
Air Pressure Regulating Valve Motor Duty Air pressure regulating valve motor control duty Min.: 0%, Max.: 127.5% - -
Air Shunt Valve Position Air shunt valve opening angle Min.: -250 deg, Max.: 249.99 deg - -
Air Sealing Valve Position Air sealing valve opening angle Min.: -250 deg, Max.: 249.99 deg - -
Air Pressure Regulating Valve Position Air pressure regulating valve opening angle Min.: -250 deg, Max.: 249.99 deg - -
Air Shunt Valve Position Sensor Voltage Output voltage of the air shunt valve position sensor Min.: 0 V, Max.: 4.99 V - -
Air Sealing Valve Position Sensor Voltage Output voltage of the air sealing valve position sensor Min.: 0 V, Max.: 4.99 V - -
Air Pressure Regulating Valve Position Sensor Voltage Output voltage of the air pressure regulating valve position sensor Min.: 0 V, Max.: 4.99 V - -
Radiator Rotary Valve Fail Status (WRA1) FC cooling water temperature control valve (WRA1) fail status ON/OFF/Unknown - -
Radiator Rotary Valve Carrying Request (WRA1) Actuation requests of the FC cooling water temperature control valve (WRA1) ON/OFF - -
Radiator Rotary Valve Fail Status (WRA2) FC cooling water temperature control valve (WRA2) fail status ON/OFF/Unknown - -
Radiator Rotary Valve Carrying Request (WRA2) Actuation requests of the FC cooling water temperature control valve (WRA2) ON/OFF - -
Radiator Rotary Valve Fail Status (WRB1) FC cooling water temperature control valve (WRB1) fail status ON/OFF/Unknown - -
Radiator Rotary Valve Carrying Request (WRB1) Actuation requests of the FC cooling water temperature control valve (WRB1) ON/OFF - -
Radiator Rotary Valve Fail Status (WRB2) FC cooling water temperature control valve (WRB2) fail status ON/OFF/Unknown - -
Radiator Rotary Valve Carrying Request (WRB2) Actuation requests of the FC cooling water temperature control valve (WRB2) ON/OFF - -
Hydrogen Injector 1 Current Offset No. 1 fuel injector assembly current calibration ON/OFF ON: No. 1 fuel injector assembly current calibration being performed -
Hydrogen Injector 2 Current Offset No. 2 fuel injector assembly current calibration ON/OFF ON: No. 2 fuel injector assembly current calibration being performed -
Hydrogen Injector 3 Current Offset No. 3 fuel injector assembly current calibration ON/OFF ON: No. 3 fuel injector assembly current calibration being performed -
Hydrogen Injector 1 Terminal Status No. 1 fuel injector assembly terminal status High/Low High: Ignition switch ON (READY) -
Hydrogen Injector 2 Terminal Status No. 2 fuel injector assembly terminal status High/Low High: Ignition switch ON (READY) -
Hydrogen Injector 3 Terminal Status No. 3 fuel injector assembly terminal status High/Low High: Ignition switch ON (READY) -
Hydrogen Injector 1 Injection Injection requests to No. 1 fuel injector assembly ON/OFF ON:
Requesting No. 1 fuel injector assembly to inject
-
Hydrogen Injector 2 Injection Injection requests to No. 2 fuel injector assembly ON/OFF ON:
Requesting No. 2 fuel injector assembly to inject
-
Hydrogen Injector 3 Injection Injection requests to No. 3 fuel injector assembly ON/OFF ON:
Requesting No. 3 fuel injector assembly to inject
-
FC Air Compressor Motor Temperature Sensor Voltage Output voltage of the FC air compressor motor temperature sensor Min.: 0 V, Max.: 4.99 V - -
Emergency Shutdown Signal Emergency shutdown signal ON/OFF OFF: Constant -


Data List (FCDC)


NOTICE:
·

Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.

·

In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.



a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / FCDC / Data List.


e.

Check the results by referring to the following table.

Powertrain > FCDC > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Drive total distance Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) - -
Total Distance Traveled - Unit Unit of drive total distance km/mile - -
IG2 Status (Line) IGSW terminal condition ON/OFF ON: Ignition switch ON -
Ready Status State of system (READY) ON/OFF ON: Ignition switch ON (READY) -
Shutdown Request (Hybrid/EV) Inverter shutdown signal status ON/OFF - -
Inverter Shutdown Status Inverter shutdown status ON/OFF - -
Fail Safe Status Control data for fail-safe control ON/OFF - -
Total Voltage FC stack power generation voltage calculated from the cell monitor (Total amount of each cell voltages) Min.: 0 V, Max.: 1023.98 V 0 to 330 V -
FC Voltage (Filtered Value) FC converter input voltage sensor filtered value (voltage before boosting) Min.: -3276.8 V, Max.: 3276.7 V 0 to 330 V -
FC Converter Output Voltage (Filtered Value) FC converter output voltage sensor filtered value (voltage after boosting) Min.: -3276.8 V, Max.: 3276.7 V 0 to 650 V -
FC Voltage FC converter input voltage sensor value (voltage before boosting) Min.: 0 V, Max.: 6553.5 V 0 to 330 V Value of the FVL sensor located inside the FC converter
FC Converter Output Voltage FC converter output voltage sensor value (voltage after boosting) Min.: -3276.8 V, Max.: 3276.7 V 0 to 650 V Value of the FVH sensor located inside the FC converter
Power Supply Monitor Voltage (+B) +B1, +B2 terminal voltage Min.: 0 V, Max.: 4.98 V - -
Power Supply Monitor Voltage (-5V) -5 V Power source CPU input AD value Min.: 0 V, Max.: 4.98 V - -
VH Voltage Inverter voltage sensor value (voltage after boosting) Min.: 0 V, Max.: 1023.98 V 0 to 330 V -
Smoothed Value of BATT Voltage Smoothed value of auxiliary battery voltage Min.: 0 V, Max.: 65.535 V - -
FC Current FC current sensor value Min.: -3276.8 A, Max.: 3276.7 A 0 to 600 A -
FC Current Upper Limit FC current upper limit when limiting output Min.: -3276.8 A, Max.: 3276.7 A 0 to 600 A Maximum FC current value that is currently allowed when the FC boost control ECU must limit output
Target FC Current (Hybrid/EV) Output current command value for the FC system Min.: 0 A, Max.: 3999.93 A 0 to 600 A -
FC Current (Filtered Value) FC current filtered value Min.: 0 A, Max.: 3999.93 A 0 to 600 A -
FCP Relay Drive Request Actuation requests of the FRP relay ON/OFF - -
FCG Relay Drive Request Actuation requests of the FRG relay ON/OFF - -
FCB Relay Drive Request Actuation requests of the FRB relay ON/OFF - -
Hybrid/EV Coolant Temperature EV coolant temperature Min.: -40°C (-40°F), Max.: 215°C (419°F) - -
Phase U Duty Phase U current duty value Min.: 0%, Max.: 399.99% 0 to 98% -
Phase U Temperature 1 Phase U temperature 1 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 1 converted to temperature
Phase U Temperature 2 Phase U temperature 2 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 2 converted to temperature
Phase U Temperature 1 Duty Phase U temperature sensor 1 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase U. A temperature sensor is attached to each element for use in measuring the temperature.
Phase U Temperature 2 Duty Phase U temperature sensor 2 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase U. A temperature sensor is attached to each element for use in measuring the temperature.
Phase U Temperature 1 (Filtered Value) Phase U temperature filtered value Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Filtered value of either phase U temperature 1 or phase U temperature 2, whichever is largest
Phase U Current Phase U current Min.: -3276.8 A, Max.: 3276.7 A 0 to 150 A -
Phase U Current AD Value AD value of phase U current Min.: 0 V, Max.: 4.99 V - -
Phase U Current (Offset Value) Phase U current offset value Min.: -3276.8 A, Max.: 3276.7 A - -
Phase V Duty Phase V current duty value Min.: 0%, Max.: 399.99% 0 to 98% -
Phase V Temperature 1 Phase V temperature 1 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 1 converted to temperature
Phase V Temperature 2 Phase V temperature 2 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 2 converted to temperature
Phase V Temperature 1 Duty Phase V temperature sensor 1 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase V. A temperature sensor is attached to each element for use in measuring the temperature.
Phase V Temperature 2 Duty Phase V temperature sensor 2 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase V. A temperature sensor is attached to each element for use in measuring the temperature.
Phase V Temperature 1 (Filtered Value) Phase V temperature filtered value Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Filtered value of either phase V temperature 1 or phase V temperature 2, whichever is largest
Phase V Current Phase V current Min.: -3276.8 A, Max.: 3276.7 A 0 to 150 A -
Phase V Current AD Value AD value of phase V current Min.: 0 V, Max.: 4.98 V - -
Phase V Current (Offset Value) Phase V current offset value Min.: -3276.8 A, Max.: 3276.7 A - -
Phase W Duty Phase W current duty value Min.: 0%, Max.: 399.99% 0 to 98% -
Phase W Temperature 1 Phase W temperature 1 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 1 converted to temperature
Phase W Temperature 2 Phase W temperature 2 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 2 converted to temperature
Phase W Temperature 1 Duty Phase W temperature sensor 1 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase W. A temperature sensor is attached to each element for use in measuring the temperature.
Phase W Temperature 2 Duty Phase W temperature sensor 2 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase W. A temperature sensor is attached to each element for use in measuring the temperature.
Phase W Temperature 1 (Filtered Value) Phase W temperature filtered value Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Filtered value of either phase W temperature 1 or phase W temperature 2, whichever is largest
Phase W Current Phase W current Min.: -3276.8 A, Max.: 3276.7 A 0 to 150 A -
Phase W Current AD Value AD value of phase W current Min.: 0 V, Max.: 4.98 V - -
Phase W Current (Offset Value) Phase W current offset value Min.: -3276.8 A, Max.: 3276.7 A - -
Phase X Duty Phase X current duty value Min.: 0%, Max.: 399.99% 0 to 98% -
Phase X Temperature 1 Phase X temperature 1 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 1 converted to temperature
Phase X Temperature 2 Phase X temperature 2 Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Value of output duty from the temperature sensor 2 converted to temperature
Phase X Temperature 1 Duty Phase X temperature sensor 1 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase X. A temperature sensor is attached to each element for use in measuring the temperature.
Phase X Temperature 2 Duty Phase X temperature sensor 2 output duty value Min.: 0%, Max.: 399.99% - There are 2 switching elements configured in a line for phase X. A temperature sensor is attached to each element for use in measuring the temperature.
Phase X Temperature 1 (Filtered Value) Phase X temperature filtered value Min.: -40°C (-40°F), Max.: 215.99°C (420.78°F) 15°C (59°F) to 150°C (302°F) Filtered value of either phase X temperature 1 or phase X temperature 2, whichever is largest
Phase X Current Phase X current Min.: -3276.8 A, Max.: 3276.7 A 0 to 150 A -
Phase X Current AD Value AD value of phase X current Min.: 0 V, Max.: 4.98 V - -
Phase X Current (Offset Value) Phase X current offset value Min.: -3276.8 A, Max.: 3276.7 A - -


Data List (HYDROGEN FILLING CONTROL)


NOTICE:
·

Some Data List values may vary significantly if there are slight differences in the vehicle condition. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.

·

In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under same conditions in order to reach an overall judgment by comparing all the items in the Data List.



a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Hydrogen Filling Control / Data List.


e.

Check the results by referring to the following table.

Powertrain > Hydrogen Filling Control > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Total Distance Traveled Drive total distance Min.: 0 [km] (0 [mile]), Max.: 16777215 [km] (10425361 [mile]) - -
Total Distance Traveled - Unit Unit of drive total distance km/mile - -
IG2 Status IGSW terminal state ON/OFF ON: Ignition switch ON -
Ready Status State of system (READY) ON/OFF ON: Ignition switch ON (READY) -
Vehicle Speed Vehicle speed Min.: 0 km (0 mile), Max.: 255 km (158 mile) 0 km/h (0 mph):
Vehicle stopped
No significant fluctuation:
While driving at a constant speed
-
Smoothed Value of BATT Voltage Smoothed value of auxiliary battery voltage (BATT terminal) Min.: 0 V, Max.: 65.535 V Constant:
11 to 15 V
-
System Power Supply Relay Drive Signal HF-B relay actuation signal ON/OFF ON: Ignition switch ON The EV control ECU switches the HF-B relay on or off.
Hydrogen Intake Pressure Sensor Voltage Output voltage of the hydrogen tank pressure sensor (for inlet side) Min.: 0 V, Max.: 4.99 V - If the "Hydrogen Intake Pressure Sensor Voltage" is more than 4.95 V or less than 0.55 V, it is suspected that an open or short has occurred in the sensor circuit.
Hydrogen Intake Pressure Sensor Power Supply Voltage Power source voltage of the hydrogen tank pressure sensor (for inlet side) Min.: 0 V, Max.: 4.99 V - -
Hydrogen Intake Pressure Sensor Power Supply Status Status of the hydrogen tank pressure sensor (for inlet side) power source ON/OFF - -
Hydrogen Tank Temperature Sensor Power Supply Status Status of the built-in hydrogen temperature sensor power source of the hydrogen tank assembly ON/OFF - -
Hydrogen Tank 1 Temperature Sensor Voltage Output voltage of the built-in hydrogen temperature sensor of the No. 1 hydrogen tank assembly Min.: 0 V, Max.: 4.99 V - -
Hydrogen Tank 2 Temperature Sensor Voltage Output voltage of the built-in hydrogen temperature sensor of the No. 2 hydrogen tank assembly Min.: 0 V, Max.: 4.99 V - -
Hydrogen Tank 3 Temperature Sensor Voltage Output voltage of the built-in hydrogen temperature sensor of the No. 3 hydrogen tank assembly Min.: 0 V, Max.: 4.99 V - -
Number of Tanks (Memory) Number of hydrogen tanks assemblies stored by the hydrogen fuel control ECU Min.: 0, Max.: 255 3 -
Number of Tanks (Hybrid/EV Control) Number of tanks received from the EV control ECU Min.: 0, Max.: 255 3 -
Number of Tanks (Recognition) Number of tanks read from the Hydrogen Tank 3 Temperature Sensor Voltage Min.: 0, Max.: 255 3 -
Lid Open Relay FUEL LID OPN relay status ON/OFF ON: FUEL LID OPN relay is operating -
Tank Shut Valve Power Supply Relay Driving Status HF-B relay actuation status ON/OFF ON: Ignition switch ON
OFF: Ignition switch off
The EV control ECU switches the H2 SHUT VLV relay on or off.
Tank Shut Valve 1 Current Keeping Control Status Current keeping control status to the tank shut valve of the No. 1 hydrogen tank assembly ON/OFF ON: Ignition switch ON (READY)
OFF: READY off
-
Tank Shut Valve 2 Current Keeping Control Status Current keeping control status to the tank shut valve of the No. 2 hydrogen tank assembly ON/OFF ON: Ignition switch ON (READY)
OFF: READY off
-
Tank Shut Valve 3 Current Keeping Control Status Current keeping control status to the tank shut valve of the No. 3 hydrogen tank assembly ON/OFF ON: Ignition switch ON (READY)
OFF: READY off
-
Tank Shut Valve 1 Drive Request Actuation requests to the tank shut valve of the No. 1 hydrogen tank assembly ON/OFF ON: Ignition switch ON (READY)
OFF: READY off
Requests are off during hydrogen leak inspection of vehicle control
Tank Shut Valve 2 Drive Request Actuation requests to the tank shut valve of the No. 2 hydrogen tank assembly ON/OFF ON: Ignition switch ON (READY)
OFF: READY off
Requests are off during hydrogen leak inspection of vehicle control
Tank Shut Valve 3 Drive Request Actuation requests to the tank shut valve of the No. 2 hydrogen tank assembly ON/OFF ON: Ignition switch ON (READY)
OFF: READY off
Requests are off during hydrogen leak inspection of vehicle control
Tank Shut Valve 1 Voltage Output voltage of the No. 1 hydrogen tank assembly (tank shut valve 1) Min.: 0 V, Max.: 4.99 V - -
Tank Shut Valve 2 Voltage Output voltage of the No. 2 hydrogen tank assembly (tank shut valve 2) Min.: 0 V, Max.: 4.99 V - -
Tank Shut Valve 3 Voltage Output voltage of the No. 3 hydrogen tank assembly (tank shut valve 3) Min.: 0 V, Max.: 4.99 V - -
Infrared Transmitter Power Supply Malfunction Power source malfunction of the hydrogen fuel control transmitter ON/OFF ON: Hydrogen fuel control transmitter power source abnormal -
Infrared Transmitter Power Supply Status Status of the hydrogen fuel control transmitter power source ON/OFF ON: Hydrogen fuel control transmitter operating -
Infrared Transmitter Power Supply Voltage Power source voltage of the hydrogen fuel control transmitter Min.: 0 V, Max.: 4.99 V - -