Home › Vehicle Exterior › DOOR / HATCH › DOOR CLOSER SYSTEM › from 2021.08
RM37H0E _59 Vehicle Exterior _095314 DOOR / HATCH _0491384 DOOR CLOSER SYSTEM U

DOOR / HATCH  DOOR CLOSER SYSTEM  TERMINALS OF ECU  


CHECK REAR MULTIPLEX NETWORK DOOR ECU LH


a.

Disconnect the F16 rear multiplex network door ECU LH connector.

B340249E17
2.885,0.26 3.302,0.5 0.417,0.24 4.073,0.26 4.49,0.5 0.417,0.24 2.979,0.292 3.281,0.479 0.302,0.188 10 false F15 4.167,0.292 4.469,0.479 0.302,0.188 10 false F16


b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
F16-1 (GND) - Body ground Ground Always Below 1 Ω
F16-4 (BDR) - Body ground Auxiliary battery power supply Ignition switch off 11 to 14 V
F16-11 (CPUB) - Body ground Auxiliary battery power supply Ignition switch off 11 to 14 V


c.

Reconnect the F16 rear multiplex network door ECU LH connector.


d.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
F15-1 (A2+) - F15-2 (A2-) Rear door with motor lock assembly LH (door closer motor) output signal Rear door LH side door open → Closer operation → Fully closed Below 1 V → 11 to 14 V → Below 1 V
F15-9 (CPSE) - Body ground Rear door with motor lock assembly LH (each switch) ground Always Below 1 Ω
F15-10 (STOP) - F15-9 (CPSE) Rear door with motor lock assembly LH (temporarily stop switch) input signal Rear door LH side door open → Fully closed (closer operation) Below 1 V → 11 to 14 V
F15-11 (H/FU) - F15-9 (CPSE) Rear door with motor lock assembly LH (half/full latch switch) input signal Rear door LH side door open → Fully closed (closer operation) Below 1 V → 11 to 14 V
F15-12 (POLE) - F15-9 (CPSE) Rear door with motor lock assembly LH (pawl switch) input signal Rear door LH side door open → Fully closed (closer operation) 11 to 14 V → Below 1 V → 11 to 14 V → Below 1 V → 11 to 14 V
F15-13 (INIT) - F15-9 (CPSE) Rear door with motor lock assembly LH (former position switch) input signal Rear door LH side door open → Fully closed (closer operation) 11 to 14 V → Below 1 V → 11 to 14 V
F15-14 (HNDL) - F15-9 (CPSE) Rear door with motor lock assembly LH (handle switch) input signal Rear door LH side door outside or inside handle not pulled 11 to 14 V
Rear door LH side door outside or inside handle pulled Below 1 V



CHECK REAR MULTIPLEX NETWORK DOOR ECU RH


a.

Disconnect the F5 rear multiplex network door ECU RH connector.

B340249E18
2.885,0.26 3.302,0.5 0.417,0.24 4.073,0.26 4.49,0.5 0.417,0.24 3.01,0.292 3.313,0.479 0.302,0.188 10 false F4 4.208,0.292 4.51,0.479 0.302,0.188 10 false F5


b.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
F5-1 (GND) - Body ground Ground Always Below 1 Ω
F5-4 (BDR) - Body ground Auxiliary battery power supply Ignition switch off 11 to 14 V
F5-11 (CPUB) - Body ground Auxiliary battery power supply Ignition switch off 11 to 14 V


c.

Reconnect the F5 rear multiplex network door ECU RH connector.


d.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Terminal Description Condition Specified Condition
F4-1 (A2+) - F4-2 (A2-) Rear door with motor lock assembly RH (door closer motor) output signal Rear door RH side door open → Closer operation → Fully closed Below 1 V → 11 to 14 V → Below 1 V
F4-9 (CPSE) - Body ground Rear door with motor lock assembly RH (each switch) ground Always Below 1 Ω
F4-10 (STOP) - F4-9 (CPSE) Rear door with motor lock assembly RH (temporarily stop switch) input signal Rear door RH side door open → Fully closed (closer operation) Below 1 V → 11 to 14 V
F4-11 (H/FU) - F4-9 (CPSE) Rear door with motor lock assembly RH (half/full latch switch) input signal Rear door RH side door open → Fully closed (closer operation) Below 1 V → 11 to 14 V
F4-12 (POLE) - F4-9 (CPSE) Rear door with motor lock assembly RH (pawl switch) input signal Rear door RH side door open → Fully closed (closer operation) 11 to 14 V → Below 1 V → 11 to 14 V → Below 1 V → 11 to 14 V
F4-13 (INIT) - F4-9 (CPSE) Rear door with motor lock assembly RH (former position switch) input signal Rear door RH side door open → Fully closed (closer operation) 11 to 14 V → Below 1 V → 11 to 14 V
F4-14 (HNDL) - F4-9 (CPSE) Rear door with motor lock assembly RH (handle switch) input signal Rear door RH side door outside or inside handle not pulled 11 to 14 V
Rear door RH side door outside or inside handle pulled Below 1 V