CHECK REAR MULTIPLEX NETWORK DOOR ECU LH
Disconnect the F16 rear multiplex network door ECU LH connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| F16-1 (GND) - Body ground | Ground | Always | Below 1 Ω |
| F16-4 (BDR) - Body ground | Auxiliary battery power supply | Ignition switch off | 11 to 14 V |
| F16-11 (CPUB) - Body ground | Auxiliary battery power supply | Ignition switch off | 11 to 14 V |
Reconnect the F16 rear multiplex network door ECU LH connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| F15-1 (A2+) - F15-2 (A2-) | Rear door with motor lock assembly LH (door closer motor) output signal | Rear door LH side door open → Closer operation → Fully closed | Below 1 V → 11 to 14 V → Below 1 V |
| F15-9 (CPSE) - Body ground | Rear door with motor lock assembly LH (each switch) ground | Always | Below 1 Ω |
| F15-10 (STOP) - F15-9 (CPSE) | Rear door with motor lock assembly LH (temporarily stop switch) input signal | Rear door LH side door open → Fully closed (closer operation) | Below 1 V → 11 to 14 V |
| F15-11 (H/FU) - F15-9 (CPSE) | Rear door with motor lock assembly LH (half/full latch switch) input signal | Rear door LH side door open → Fully closed (closer operation) | Below 1 V → 11 to 14 V |
| F15-12 (POLE) - F15-9 (CPSE) | Rear door with motor lock assembly LH (pawl switch) input signal | Rear door LH side door open → Fully closed (closer operation) | 11 to 14 V → Below 1 V → 11 to 14 V → Below 1 V → 11 to 14 V |
| F15-13 (INIT) - F15-9 (CPSE) | Rear door with motor lock assembly LH (former position switch) input signal | Rear door LH side door open → Fully closed (closer operation) | 11 to 14 V → Below 1 V → 11 to 14 V |
| F15-14 (HNDL) - F15-9 (CPSE) | Rear door with motor lock assembly LH (handle switch) input signal | Rear door LH side door outside or inside handle not pulled | 11 to 14 V |
| Rear door LH side door outside or inside handle pulled | Below 1 V |
CHECK REAR MULTIPLEX NETWORK DOOR ECU RH
Disconnect the F5 rear multiplex network door ECU RH connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| F5-1 (GND) - Body ground | Ground | Always | Below 1 Ω |
| F5-4 (BDR) - Body ground | Auxiliary battery power supply | Ignition switch off | 11 to 14 V |
| F5-11 (CPUB) - Body ground | Auxiliary battery power supply | Ignition switch off | 11 to 14 V |
Reconnect the F5 rear multiplex network door ECU RH connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| F4-1 (A2+) - F4-2 (A2-) | Rear door with motor lock assembly RH (door closer motor) output signal | Rear door RH side door open → Closer operation → Fully closed | Below 1 V → 11 to 14 V → Below 1 V |
| F4-9 (CPSE) - Body ground | Rear door with motor lock assembly RH (each switch) ground | Always | Below 1 Ω |
| F4-10 (STOP) - F4-9 (CPSE) | Rear door with motor lock assembly RH (temporarily stop switch) input signal | Rear door RH side door open → Fully closed (closer operation) | Below 1 V → 11 to 14 V |
| F4-11 (H/FU) - F4-9 (CPSE) | Rear door with motor lock assembly RH (half/full latch switch) input signal | Rear door RH side door open → Fully closed (closer operation) | Below 1 V → 11 to 14 V |
| F4-12 (POLE) - F4-9 (CPSE) | Rear door with motor lock assembly RH (pawl switch) input signal | Rear door RH side door open → Fully closed (closer operation) | 11 to 14 V → Below 1 V → 11 to 14 V → Below 1 V → 11 to 14 V |
| F4-13 (INIT) - F4-9 (CPSE) | Rear door with motor lock assembly RH (former position switch) input signal | Rear door RH side door open → Fully closed (closer operation) | 11 to 14 V → Below 1 V → 11 to 14 V |
| F4-14 (HNDL) - F4-9 (CPSE) | Rear door with motor lock assembly RH (handle switch) input signal | Rear door RH side door outside or inside handle not pulled | 11 to 14 V |
| Rear door RH side door outside or inside handle pulled | Below 1 V |