84485C
1.INSPECT POWER OUTLET SWITCH
Inspect the resistance:
| *1 | Indicator |
| *a | Component without harness connected
(Power Outlet Switch) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D111)Location & Routingewd_type=routing;type=c;code=D111 Click Connector(D111)Instrument Panel>Instrument Panel Wire>Power Outlet Switchewd_type=component;type=c;code=D111;pinno=5,2 |
||
| D111-5 (INV) - D111-2 (E) | Power outlet switch not pushed | 10 kΩ or higher |
| D111-5 (INV) - D111-2 (E) | Power outlet switch being pushed and hold | Below 1 Ω |
If the result is not as specified, replace the power outlet switch.
Inspect the indicator illumination:
Apply battery voltage to the power outlet switch and check that the switch indicator illuminates.
| Condition | Specified Condition |
|---|---|
| Battery positive (+) → D111-3 (IG)
Battery negative (-) → D111-4 (IND) |
Illuminates |
If the result is not as specified, replace the power outlet switch.
Inspect the illumination switch:
| *1 | Illumination |
| *a | Component without harness connected
(Power Outlet Switch) |
Apply battery voltage to the power outlet switch and check that the switch illuminates.
| Condition | Specified Condition |
|---|---|
| Battery positive (+) → D111-6 (ILL+)
Battery negative (-) → D111-1 (ILL-) |
Illuminates |
If the result is not as specified, replace the power outlet switch.