Home › Engine / Hybrid System › FUEL › FUEL SYSTEM › from 2021.08
RM37H0E _51 Engine / Hybrid System _097300 FUEL _0465031 FUEL SYSTEM N

FUEL  FUEL SYSTEM  DISPOSAL  


CAUTION / NOTICE / HINT

CAUTION:
·

Do not perform the procedures within 8 meters of any ignition sources. (A distance of 10 meters or more is recommended.)

·

Before performing this procedure for the hydrogen tank assembly, make sure to discharge the compressed hydrogen gas from the medium-pressure port (hydrogen supply regulator assembly) and that the pressure inside the hydrogen tank assembly is approximately 0.8 MPa (8.2 kgf/cm2).

·

Because the hydrogen tank assembly is extremely heavy, be sure to perform these procedures with 2 people or more.

·

Perform the procedures outdoors in a well-ventilated area.



NOTICE:

Dispose of the hydrogen tank according to local regulations.


PROCEDURE

Hide 1.DISPOSE OF HYDROGEN TANK ASSEMBLY

CAUTION:
·

To prevent static electricity, spray water on the hydrogen tank assembly and around the work area.

·

Before performing work procedures, touch a metal object in contact with the ground in order to discharge any static electricity from your body.

·
A482144

While releasing compressed hydrogen gas, the temperature inside the tank decreases and frost may form on the outside. Do not touch tanks when frost has formed on them.

·

Touching tanks on which frost has formed could result in burn-like injuries due to frostbite.



HINT:

Before performing this procedure, make sure that the compressed hydrogen gas has been fully released from the hydrogen tank assembly.


a.
A509082C01
2.344,0.615 2.615,0.365 2.615,0.365 2.781,0.365 false 2.823,0.281 3.135,0.438 0.313,0.156 10 false *a
*a Belt


Secure the hydrogen tank assembly to the work table with the belt in the orientation shown in the illustration.


b.
A509083C01
2.125,1.094 2.271,1.26 2.271,1.26 2.271,1.406 true 2.146,0.552 2.458,0.708 0.313,0.156 10 true *a 2.229,1.427 2.542,1.583 0.313,0.156 10 true *b
*a Manual Valve Closed
*b Adjustment Bolt


Using an 8 mm socket hexagon wrench, apply the specified torque to the adjustment bolt, and check that the manual valve is closed.

Torque:
25 N*m (255 kgf*cm, 18 ft.*lbf)

NOTICE:

Rotate the manual valve adjustment bolt, taking care not to damage the hexagonal portion. Do not damage the hexagonal portion of the adjustment bolt as the manual valve is the part that cuts off the pressure from the hydrogen tank assembly, and this would make it difficult to discharge compressed hydrogen gas from the hydrogen tank assembly.



c.
A509084C01
1.073,1.042 0.927,0.813 0.927,0.813 0.781,0.813 true 1.479,0.938 1.479,1.25 true 0.563,0.719 0.771,0.875 0.208,0.156 10 true *a 1.417,1.271 1.615,1.417 0.198,0.146 10 true *b
*a Resin
*b Screwdriver


Using a screwdriver, remove the resin around the release valve of the hydrogen tank assembly.


d.
A509085

Using an 8 mm socket hexagon wrench, slowly loosen the release valve of the hydrogen tank valve assembly to discharge the compressed hydrogen gas.

NOTICE:
·

The compressed hydrogen gas left in the hydrogen tank valve assembly will be discharged, so slowly loosen until no more compressed hydrogen gas comes out.

·

If compressed hydrogen gas continues to be discharged, close the release valve of the hydrogen tank valve assembly and reconfirm that the manual valve of the hydrogen tank assembly is closed.




e.
A509086C01
2.281,1 2.448,1.146 2.448,1.146 2.583,1.146 true 2.146,0.563 2.458,0.719 0.313,0.156 10 false *a 2.604,1.052 2.802,1.208 0.198,0.156 10 false *b
*a Manual Valve Open
*b Adjustment Bolt


Using an 8 mm socket hexagon wrench, slowly rotate the adjustment bolt counterclockwise to open the manual valve of the hydrogen tank assembly until compressed hydrogen gas is no longer discharged.

NOTICE:
·

Rotate the manual valve adjustment bolt, taking care not to damage the hexagonal portion. Do not damage the hexagonal portion of the adjustment bolt as the manual valve is the part that cuts off the pressure from the hydrogen tank assembly, and this would make it difficult to discharge compressed hydrogen gas from the hydrogen tank assembly.

·

Do not rotate the adjustment bolt 4 or more turns, as this may damage the manual valve.




f.
A509087C01
2.365,0.604 2.531,0.427 2.531,0.427 2.708,0.427 false 2.75,0.354 3.063,0.552 0.313,0.198 10 false *a
*a Belt


Secure the hydrogen tank assembly with the belt in the orientation shown in the illustration.


g.
A481990

Using a T20 "TORX" socket wrench, disconnect the 2 screws and disconnect the wire harness from the hydrogen tank valve assembly.


h.
A481991C01
1.281,0.698 0.771,0.521 0.771,0.521 0.625,0.521 true 1.74,3.615 0.927,3.427 0.927,3.427 0.781,3.427 true 1.729,2.813 1.281,2.813 false 0.333,0.448 0.677,0.625 0.344,0.177 10 false SST 0.583,3.344 0.802,3.5 0.219,0.156 10 false *a 1.01,2.74 1.354,2.917 0.344,0.177 10 false SST
*a SST Installation Area


Using a 13 mm socket wrench, install SST (hydrogen tank holding tool) to the hydrogen tank valve assembly.

SST
09403-62021  (09403-00010)

Torque:
28 N*m (286 kgf*cm, 21 ft.*lbf)


i.

Remove the hydrogen tank valve assembly.

i.
A481992C01
3.104,1.271 3.417,1.427 0.313,0.156 10 false *a
*a Hold
V113147

Turn


While holding SST (hydrogen tank holding tool), rotate the hydrogen tank valve assembly to loosen the valve.

Tightening torque (reference):
Hydrogen tank valve assembly:

485 N*m (4946 kgf*cm, 358 ft.*lbf)


CAUTION:

Because the tightening torque of the hydrogen tank valve assembly is extremely high, perform this operation with 2 people.



ii.
A481993N01
1.104,0.646 0.677,0.344 0.677,0.344 0.51,0.344 true 0.229,0.281 0.688,0.479 0.458,0.198 10 false SST

Remove SST (hydrogen tank holding tool) from the hydrogen tank valve assembly.


iii.
A481994

Remove the hydrogen tank valve assembly.



j.

Remove the hydrogen tank assembly from the work table.


k.

Soak the interior of the hydrogen tank assembly with water.

i.
A481995

Spray water into the hydrogen tank assembly through the valve installation hole as shown in the illustration.

NOTICE:

To prevent static electricity from being generated when blowing compressed air into the hydrogen tank assembly through the valve installation hole, make sure to perform this procedure.


HINT:

Water filling amount: Approximately 10 liters (10.6 US qts, 8.8 Imp. qts).



ii.
A481996C01
0,0 0,0 false
*a Rotate


Rotate the hydrogen tank assembly 1 or more times so that the water is completely spread throughout the inside of the hydrogen tank assembly.

NOTICE:

To prevent static electricity from being generated when blowing compressed air into the hydrogen tank assembly through the valve installation hole, make sure to perform this procedure.




l.
A481997C01
2.135,1.135 2.698,1.135 true 2.719,1.052 3.031,1.25 0.313,0.198 10 false *a
*a Belt


Use a belt to secure the hydrogen tank assembly vertically.

CAUTION:

Because the hydrogen tank assembly is extremely heavy, be sure to perform these procedures with 2 people or more.


NOTICE:

To prevent the hydrogen tank assembly from falling over, use a belt to secure the hydrogen tank assembly.



m.

Measure the hydrogen gas concentration.

i.
A481998

Before measuring the hydrogen gas concentration, blow compressed air into the hydrogen tank assembly through the hydrogen tank valve installation hole.

HINT:

Perform in order to force out hydrogen gas that may remain in the hydrogen tank assembly and release it into the atmosphere.



ii.

If there are any water droplets, etc. adhering to the measurement locations, wipe them away before measuring the hydrogen gas concentration.

NOTICE:

Performing the measurement while any water droplets, etc. are adhering could damage the hydrogen gas detector.



iii.
A481999C02
2.281,0.583 1.875,0.188 1.875,0.188 1.698,0.188 true 1.406,0.969 1.156,0.698 1.156,0.698 0.979,0.698 true 0.688,0.604 1.01,0.781 0.323,0.177 10 false SST 1.521,0.083 1.833,0.24 0.313,0.156 10 false *a
*a Hydrogen Gas Detector
V113146

Hydrogen Concentration Measurement Area


Using SST and a hydrogen gas detector, measure the hydrogen gas concentration at the location shown in the illustration.

SST
09401-62020  

Specified value:

Less than 500 ppm


HINT:
·

If the hydrogen tank assembly is left standing vertically for approximately 1 day, the hydrogen concentration becomes 500 ppm or less. (Make sure to leave it in an area with good ventilation for at least 8 hours.)

·

Immediately after the measurement starts, the measured value may be unstable.

·

Measure the gas concentration for approximately 10 seconds continuously.





n.
A482140C01
2.063,0.688 0.802,0.271 0.802,0.271 0.531,0.271 true 1,0.99 0.781,0.271 true 1.667,1.604 2.688,1.833 2.688,1.833 2.979,1.833 false 2.708,1.365 2.688,1.823 false 0.354,0.188 0.667,0.344 0.313,0.156 10 false *a 3.01,1.75 3.219,1.906 0.208,0.156 10 false *a
*a Wheel Chocks


Place the hydrogen tank assembly on wheel chocks or similar.


o.
A482000

Using a drill, open 2 or more holes on the hydrogen tank assembly.

Hole diameter:

12.5 mm (0.492 in.) or more


CAUTION:
·
A482003

Make sure to wear protective glasses when drilling the holes.

·

Drilling the holes without wearing protective glasses could result in a serious accident.



HINT:

Perform this procedure so that the hydrogen tank assembly is not reused.



p.
A482001

Destroy the threads of the valve installation hole of the hydrogen tank assembly as shown in the illustration.

HINT:

Perform this procedure so that the hydrogen tank assembly is not reused.



q.
A482002

Destroy the threads of the valve of the hydrogen tank assembly as shown in the illustration.

HINT:

Perform this procedure so that the hydrogen tank valve assembly is not reused.