Home › General › SPECIFICATIONS › POWER OUTLETS (INT) › from 2021.08
RM37H0E _V1 General _095078 SPECIFICATIONS _0491522 POWER OUTLETS (INT) F

SPECIFICATIONS  POWER OUTLETS (INT)  SERVICE DATA  


POWER OUTLET SOCKET (for Luggage Compartment)
Tester Connection Condition Specified Condition

Click Location & Routing(G159)Location & Routing

Click Connector(G159)Body>Floor Wire / No. 3 Floor Wire>No. 2 Power Outlet Socket

A - G159-2 (ACC3) Always Below 1 Ω
B - G159-1 (ACC4) Always Below 1 Ω
C - G159-4 (E) Always Below 1 Ω
D - G159-2 (ACC3) Always Below 1 Ω
E - G159-1 (ACC4) Always Below 1 Ω
G159-1 (ACC4) - G159-2 (ACC3) Always 10 kΩ or higher

POWER OUTLET SWITCH
Inspect the resistance:
Tester Connection Condition Specified Condition
D111-5 (INV) - D111-2 (E) Power outlet switch not pushed 10 kΩ or higher
D111-5 (INV) - D111-2 (E) Power outlet switch being pushed and hold Below 1 Ω

Inspect the indicator illumination:
Condition Specified Condition
Battery positive (+) → D111-3 (IG)
Battery negative (-) → D111-4 (IND)
Illuminates
Inspect the illumination switch:
Condition Specified Condition
Battery positive (+) → D111-6 (ILL+)
Battery negative (-) → D111-1 (ILL-)
Illuminates