Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › REFRIGERANT

REFRIGERANT > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET


    I038559E02
  1. Check the sight glass of the cooler unit refrigerant liquid pipe E.

    1. Set the vehicle according to the conditions below.
      Item
      Condition
      All doors
      Fully open
      Temperature setting
      MAX COLD
      Blower speed
      HI
      A/C switch
      ON

    2. Check the sight glass under these conditions.

      Item
      Symptom
      Amount of refrigerant
      Corrective Actions
      1
      Bubbles exist
      Insufficient*
      1. Check for gas leakage and repair if necessary
      2. Add refrigerant until bubbles disappear
      2
      No bubbles exist (DTC 76 is output)
      Empty, insufficient or excessive
      Refer to 3 and 4
      3
      No temperature difference between compressor inlet and outlet
      Empty or nearly empty
      1. Check for gas leakage and repair if necessary
      2. Add refrigerant until bubbles disappear
      4
      Considerable temperature difference between compressor inlet and outlet
      Proper or excessive
      Refer to 5 and 6
      5
      Immediately after air conditioning is turned off, refrigerant remains clear
      Excessive
      1. Discharge refrigerant
      2. Remove air and supply proper amount of purified refrigerant
      6
      Immediately after air conditioning is turned off, refrigerant foams and then becomes clear
      Proper
      -

      HINT:
      Bubbles in the sight glass with the room temperature higher than usual can be considered normal if cooling is sufficient.



2. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET


  1. This is a method in which the trouble is located by using a manifold gauge set. Read the manifold gauge pressure when these conditions are established.
    Gauge readings (Reference)
    Test conditions:

    1. Temperature at the air inlet with the switch set at RECIRC is 30 to 35°C (86 to 95°F)
    2. Blower speed control switch at "HI" position
    3. Temperature control switch at "MAX COLD" position
    4. A/C switch ON
    5. Fully open doors



      E050573E01
    1. The refrigeration system functions normally
      Gauge reading:

      Low-pressure side:
      0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2)

      High-pressure side:
      1.37 to 1.57 MPa (14 to 16 kgf/cm2)



    2. Moisture present in refrigeration system


      I022117E19


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      During operation, pressure on low-pressure side cycles between normal and vacuum
      Moisture in refrigerating system freezes at expansion valve orifice, causing a temporary stop of cycle. However, when it melts, normal state is restored.
      - Cooler dryer in oversaturated state
      Moisture in refrigeration system freezes at expansion valve orifice and blocks circulation of refrigerant
      1. Replace cooler dryer
      2. Remove moisture in cycle by repeatedly evacuating air
      3. Supply proper amount of new refrigerant



    3. Insufficient cooling


      I022118E11


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Pressure is low on both low and high-pressure sides
      - Bubbles are continuously seen through sight glass
      - Insufficient cooling performance
      Gas leakage in refrigeration system
      - Insufficient refrigerant
      - Refrigerant leaking
      1. Check for gas leakage and repair if necessary
      2. Supply proper amount of new refrigerant
      3. If the indicated pressure value is close to 0 when connected to the gauge, create a vacuum after inspecting and repairing location of leakage



    4. Poor circulation of refrigerant


      I022119E12


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Pressure low on both low and high-pressure sides
      - Frost exists on pipe from cooler condenser to A/C unit
      Refrigerant flow is obstructed by dirt in cooler condenser core
      Cooler condenser core is clogged
      Replace cooler condenser core



    5. Refrigerant does not circulate


      I022120E11


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Vacuum is indicated on low-pressure side and very low pressure is indicated on high- pressure side
      - Frost or condensation is seen on piping on both sides of cooler condenser core or expansion valve
      - Refrigerant flow is obstructed by moisture or dirt in refrigeration system
      - Refrigerant flow obstructed by gas leaked from cooler expansion valve
      Refrigerant does not circulate
      1. Check expansion valve
      2. Clean out dirt in cooler expansion valve by blowing air
      3. Replace cooler condenser core
      4. Evacuate and charge new refrigerant
      5. For gas leakage from cooler expansion valve, replace cooler expansion valve



    6. Refrigerant overcharged or insufficient cooling of condenser


      I022121E09


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Pressure is too high on both low and high-pressure sides
      - No air bubbles are seen through the sight glass when compressor speed decreases
      - Excessive refrigerant
      - Insufficient cooling of cooler condenser core
      - Excessive refrigerant in cycle (excessive refrigerant is supplied)
      - Insufficient cooling of cooler condenser core
      1. Clean cooler condenser core fins
      2. Check cooling fan with condenser fan motor operation
      3. If 1 and 2 normal, check the amount of refrigerant and supply proper amount of refrigerant



    7. Air present in refrigeration system


      I022122E08


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Pressure is too high on both low and high-pressure sides
      - Low-pressure piping is too hot to touch
      Bubbles are seen through sight glass
      Air in system
      - Air present in refrigeration system
      - Insufficient vacuum purging
      1. Check compressor oil to see if it is dirty or insufficient
      2. Evacuate and charge new refrigerant



    8. Expansion valve malfunction


      I022123E13


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Pressure is too high on both low and high-pressure sides
      - Frost or large amount of condensation on piping on low-pressure side
      Trouble in cooler expansion valve
      - Excessive refrigerant in low pressure piping
      - Cooler expansion valve is opened too wide
      Replace cooler expansion valve



    9. Defective compression in compressor


      I022124E09


      Symptoms
      Probable Cause
      Diagnosis
      Corrective Actions
      - Pressure is too high on both low and high-pressure sides
      - Pressure is too low on high-pressure side
      Internal leak in cooler compressor
      - Compression failure
      - Leakage from damaged valve or broken sliding parts
      Repair or replace compressor
      Gauge readings (Reference)


      I030081E04