CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY > INSPECTION |
| 1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
Measure the resistance of the oil control valve.
![]() |
Inspect the operation.
Connect the battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and inspect the movement of the valve.
| Condition | Specified Condition |
| Battery positive (+) voltage is applied | Valve moves in black arrow direction shown in illustration |
| Battery positive (+) voltage is cut off | Valve moves in white arrow direction shown in illustration |