Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › SFI SYSTEM

SFI SYSTEM > FAIL-SAFE CHART

for Preparation Click here


If any of the following codes are recorded, the ECM enters fail-safe mode.

DTC No.
Fail-safe Operation
Fail-safe Deactivation Conditions
P0031
P0032
P0037
P0038
Heater is turned OFF
Power switch OFF
P0100
P0102
P0103
Ignition timing is calculated from engine speed and throttle angle
"Pass" condition detected
P0110
P0112
P0113
Intake air temperature is fixed at 20°C (68°F)
"Pass" condition detected
P0115
P0117
P0118
Engine coolant temperature is fixed at 80°C (176°F)
"Pass" condition detected
P0120
P0122
P0123
Fuel cut intermittently and drive on motor mode
Power switch OFF
P0121
Fuel cut intermittently and drive on motor mode
Power switch OFF
P0325
Maximum ignition timing retardation
Power switch OFF
P0351
P0352
P0353
P0354
Fuel cut and drive on motor mode
Power switch OFF
P0657
VTA is fixed at about 16% and fuel cut intermittently and drive on motor mode
Power switch OFF
P1115
P1117
P1118
Engine coolant temperature is fixed at 80°C (176°F)
"Pass" condition detected
P1120
P1122
P1123
Water valve position is fixed at position when DTC is detected
"Pass" condition detected
P2102
P2103
VTA is fixed at about 16% and fuel cut intermittently
Power switch OFF
P2119
VTA is fixed at about 16% and fuel cut intermittently
"Pass" condition detected and power switch OFF
P3190
P3191
P3193
Drive on motor mode
Power switch OFF