DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0141 Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 | Heater current is less than 0.3 A when the heater operates with +B greater than 10.5 V (1 trip detection logic) |
|
| P0038 | When the heater operates, heater current exceeds 2 A (1 trip detection logic) |
|
| P0141 | Cumulative heater resistance correction value exceeds threshold (2 trip detection logic) |
|
| Related DTCs | P0037: Heated oxygen sensor heater current bank 1 sensor 2 (low current) P0038: Heated oxygen sensor heater current bank 1 sensor 2 (high current) P0141: Heated oxygen sensor heater performance |
| Required sensors/components | Main sensors: Heated oxygen sensor Related sensors: Vehicle speed sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 second: P0037 1 second: P0038 10 second: P0141 |
| MIL operation | Immediately |
| Sequence of operation | None |
| Monitor runs whenever following DTCs are not present | None |
| Battery voltage | 10.5 to 20 V |
| Battery voltage | 10.5 V or more |
| Engine | Running |
| Starter | OFF |
| Battery voltage | 10 to 20 V |
| Battery voltage | 10.5 V or more |
| Fuel cut | OFF |
| Time after fuel cut ON to OFF | 30 seconds or more |
| Accumulated heater ON time | 100 seconds or more |
| Heated oxygen sensor heater current | Less than 0.3 A (at 0.5 seconds after heater is turned ON) |
| Heated oxygen sensor heater current | More than 2 A (while supplemental heating is OFF) |
| Accumulated heater resistance | Varies with sensor element temperature (Example: more than 23 Ω) |
| Heated oxygen sensor heater current (after engine is warmed up) | 0.4 to 1.0 A (at idle and battery voltage 11 to 14 V) |
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
![]() |
Disconnect the H13 heated oxygen sensor connector.
Measure the resistance between the terminals of the heated oxygen sensor connector.
| Tester Connection | Specified Condition |
| H13-1 (HT) - H13-2 (+B) | 11 to 16 Ω at 20°C (68°F) |
| H13-1 (HT) - H13-4 (E) | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
|
| ||||
| OK | |
| 2.INSPECT INTEGRATION RELAY (EFI M RELAY) |
![]() |
Remove the integration relay from the engine room relay block.
Inspect the EFI M relay.
| Tester Connection | Specified Condition |
| 3K-1 - 3I-8 | 10 kΩ or higher |
| 3K-1 - 3I-8 | Below 1 Ω (Apply battery voltage to terminals 3I-6 and 3I-7) |
Reinstall the integration relay.
|
| ||||
| OK | |
| 3.CHECK ECM (HT1B VOLTAGE) |
![]() |
Turn the power switch ON (IG).
Measure the voltage between the applicable terminals of the E4 and E6 ECM connectors.
| Tester Connection | Specified Condition |
| E6-6 (HT1B) - E4-28 (E2) | 9 to 14 V |
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM AND EFI M RELAY) |
Check the harness and the connectors between the ECM and the heated oxygen sensor connectors.
![]() |
Disconnect the H13 heated oxygen sensor connector.
![]() |
Disconnect the E4 and E6 ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| H13-1 (HT) - E6-6 (HT1B) | Below 1 Ω |
| H13-4 (E) - E4-28 (E2) | Below 1 Ω |
| Tester Connection | Specified Condition |
| H13-1 (HT) or E6-6 (HT1B) - Body ground | 10 kΩ or higher |
| H13-1 (HT) - H13-2 (+B) | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
Reconnect the ECM connectors.
Check the harness and the connectors between the heated oxygen sensor connector and the EFI M relay.
Disconnect the H13 heated oxygen sensor connector.
![]() |
Remove the integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| H13-2 (+B) - 3I-8 (EFI M relay) | Below 1 Ω |
| Tester Connection | Specified Condition |
| H13-2 (+B) or 3I-8 (EFI M relay) - Body ground | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
Reinstall the integration relay.
|
| ||||
| OK | ||
| ||