DTC    P0037    Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)

DTC    P0038    Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2)

DTC    P0141    Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2)

for Preparation Click here


DESCRIPTION

Refer to DTC P0136 .

HINT:
The heated oxygen sensor heater circuit uses a relay on the +B side of the circuit.


B062793E26


DTC No.
DTC Detection Condition
Trouble Area
P0037
Heater current is less than 0.3 A when the heater operates with +B greater than 10.5 V
(1 trip detection logic)
  1. Open or short in heater circuit of the heated oxygen sensor
  2. Heated oxygen sensor heater
  3. EFI M relay (integration relay)
  4. ECM
P0038
When the heater operates, heater current exceeds 2 A
(1 trip detection logic)
  1. Short in heater circuit of the heated oxygen sensor
  2. Heated oxygen sensor heater
  3. EFI M relay (integration relay)
  4. ECM
P0141
Cumulative heater resistance correction value exceeds threshold (2 trip detection logic)
  1. Open or short in heated oxygen sensor
  2. Heated oxygen sensor heater (sensor 2)
  3. EFI M relay (integration relay)
  4. ECM

HINT:
  1. Sensor 1 refers to the sensor mounted before the TWC and is located near the engine assembly.
  2. Sensor 2 refers to the sensor mounted after the TWC and is located far from the engine assembly.


MONITOR DESCRIPTION

The sensing portion of the heated oxygen sensor has a zirconia element which is used to detect oxygen concentration in the exhaust gas. If the zirconia element is at the proper temperature and difference of the oxygen concentration between the inside and outside surfaces of the sensor is large, the zirconia element will generate voltage signals. In order to increase the oxygen concentration detecting capacity in the zirconia element, the ECM supplements the heat from the exhaust with heat from a heating element inside the sensor. When current in the sensor is out of the standard operating range, the ECM interprets this as a fault in the heated oxygen sensor and sets a DTC.
Heated oxygen sensor heater range check (P0037 and P0038):
  1. The ECM monitors the current applied to the heated oxygen sensor heater to check the heater for malfunctions. If the current is below the threshold value, the ECM will determine that there is an open circuit in the heater. If the current is above the threshold value, the ECM will determine that there is a short circuit in the heater.
  2. Example:
    1. The ECM sets DTC P0038 when the current in the heated oxygen sensor heater is more than 2 A. Conversely, when the heater current is less than 0.3 A, DTC P0037 is set.
Heated oxygen sensor heater performance (P0141):
  1. After the accumulated heater ON time exceeds 100 seconds, the ECM calculates the heater resistance using the battery voltage and the current applied to the heater. If the resistance is above the threshold value, the ECM will determine that there is a malfunction in the heated oxygen sensor heater and set DTC P0141.

MONITOR STRATEGY


Related DTCs
P0037: Heated oxygen sensor heater current bank 1 sensor 2 (low current)
P0038: Heated oxygen sensor heater current bank 1 sensor 2 (high current)
P0141: Heated oxygen sensor heater performance
Required sensors/components
Main sensors:
Heated oxygen sensor
Related sensors:
Vehicle speed sensor
Frequency of operation
Continuous
Duration
0.5 second: P0037
1 second: P0038
10 second: P0141
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All: 
Monitor runs whenever following DTCs are not present
None

P0037: 
Battery voltage
10.5 to 20 V

P0038 (Condition A): 
Battery voltage
10.5 V or more
Engine
Running
Starter
OFF

P0038 (Condition B): 
Battery voltage
10 to 20 V

P0141 (Heater performance monitor check): 
Battery voltage
10.5 V or more
Fuel cut
OFF
Time after fuel cut ON to OFF
30 seconds or more
Accumulated heater ON time
100 seconds or more

TYPICAL MALFUNCTION THRESHOLDS


P0037: 
Heated oxygen sensor heater current
Less than 0.3 A (at 0.5 seconds after heater is turned ON)

P0038: 
Heated oxygen sensor heater current
More than 2 A (while supplemental heating is OFF)

P0141 (Heater performance monitor check): 
Accumulated heater resistance
Varies with sensor element temperature (Example: more than 23 Ω)

COMPONENT OPERATING RANGE


Heated oxygen sensor heater current
(after engine is warmed up)
0.4 to 1.0 A (at idle and battery voltage 11 to 14 V)

MONITOR RESULT

Refer to detailed information (Click here).

WIRING DIAGRAM

Refer to DTC P0136 .

INSPECTION PROCEDURE

HINT:
  1. Read freeze frame data using Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
  2. When DTC P0038 is detected, proceed to step 4 if the heater resistance is in normal range.

1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)


    A062378E29
  1. Disconnect the H13 heated oxygen sensor connector.

  1. Measure the resistance between the terminals of the heated oxygen sensor connector.

    Standard resistance (Bank 1 sensor 2)::
    Tester Connection
    Specified Condition
    H13-1 (HT) - H13-2 (+B)
    11 to 16 Ω at 20°C (68°F)
    H13-1 (HT) - H13-4 (E)
    10 kΩ or higher

  1. Reconnect the heated oxygen sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR
OK


2.INSPECT INTEGRATION RELAY (EFI M RELAY)


    A082812E01
  1. Remove the integration relay from the engine room relay block.

  1. Inspect the EFI M relay.

    Standard resistance:
    Tester Connection
    Specified Condition
    3K-1 - 3I-8
    10 kΩ or higher
    3K-1 - 3I-8
    Below 1 Ω
    (Apply battery voltage to terminals 3I-6 and 3I-7)

  1. Reinstall the integration relay.



NG
REPLACE INTEGRATION RELAY
OK


3.CHECK ECM (HT1B VOLTAGE)


    A119979E46
  1. Turn the power switch ON (IG).

  1. Measure the voltage between the applicable terminals of the E4 and E6 ECM connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    E6-6 (HT1B) - E4-28 (E2)
    9 to 14 V



OK
REPLACE ECM
NG


4.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM AND EFI M RELAY)


  1. Check the harness and the connectors between the ECM and the heated oxygen sensor connectors.



      A066283E03
    1. Disconnect the H13 heated oxygen sensor connector.



    2. A079127E03
    3. Disconnect the E4 and E6 ECM connectors.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Specified Condition
      H13-1 (HT) - E6-6 (HT1B)
      Below 1 Ω
      H13-4 (E) - E4-28 (E2)
      Below 1 Ω

      Standard resistance (Check for short):
      Tester Connection
      Specified Condition
      H13-1 (HT) or E6-6 (HT1B) - Body ground
      10 kΩ or higher
      H13-1 (HT) - H13-2 (+B)
      10 kΩ or higher

    5. Reconnect the heated oxygen sensor connector.

    6. Reconnect the ECM connectors.



  1. Check the harness and the connectors between the heated oxygen sensor connector and the EFI M relay.

    1. Disconnect the H13 heated oxygen sensor connector.



    2. A082810E01
    3. Remove the integration relay from the engine room relay block.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Specified Condition
      H13-2 (+B) - 3I-8 (EFI M relay)
      Below 1 Ω

      Standard resistance (Check for short):
      Tester Connection
      Specified Condition
      H13-2 (+B) or 3I-8 (EFI M relay) - Body ground
      10 kΩ or higher

    5. Reconnect the heated oxygen sensor connector.

    6. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM