Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0351    Ignition Coil "A" Primary / Secondary Circuit

DTC    P0352    Ignition Coil "B" Primary / Secondary Circuit

DTC    P0353    Ignition Coil "C" Primary / Secondary Circuit

DTC    P0354    Ignition Coil "D" Primary / Secondary Circuit

for Preparation Click here


DESCRIPTION

HINT:
  1. These DTCs indicate malfunctions related to the primary circuit.
  2. If DTC P0351 is displayed, check the No.1 (#1) ignition coil circuit.
  3. If DTC P0352 is displayed, check the No.2 (#2) ignition coil circuit.
  4. If DTC P0353 is displayed, check the No.3 (#3) ignition coil circuit.
  5. If DTC P0354 is displayed, check the No.4 (#4) ignition coil circuit.

A Direct Ignition System (DIS) is used on this vehicle.
The DIS is a 1-cylinder ignition system which ignites one cylinder with one ignition coil. In the 1-cylinder ignition system, the one spark plug is connected to the end of the secondary winding. High voltage generated in the secondary winding is applied directly to the spark plug. The spark of the spark plug passes from the center electrode to the ground electrode.
The ECM determines the ignition timing and outputs the ignition (IGT) signals for each cylinder. Using the IGT signal, the ECM turns ON and OFF the power transistor inside the igniter and this switches ON and OFF the current to the primary coil. When the current flow to the primary coil is cut off, high-voltage is generated in the secondary coil and this voltage is applied to the spark plugs to spark inside the cylinders. As the ECM cuts the current to the primary coil, the igniter sends back the ignition confirmation (IGF) signal to the ECM.

A125449E01


DTC No.
DTC Detection Condition
Trouble Area
P0351
P0352
P0353
P0354
No IGF signal to ECM while engine is running
  1. Ignition system
  2. Open or short in IGF or IGT circuit from ignition coil with igniter to ECM (ignition coil circuit 1 through 4)
  3. Ignition coil with igniter (ignition coil circuit 1 through 4)
  4. ECM
Reference: Inspection using an oscilloscope.
A063956E08

HINT:
The correct waveform is as shown.
Item
Contents
Terminal
CH1: IGT1, IGT2, IGT3, IGT4 - E1
CH2: IGF - E1
Equipment Setting
2 V/DIV., 20 ms/DIV.
Condition
While the engine is cranking or idling


MONITOR DESCRIPTION


A082388E04

If the ECM does not receive the ignition confirmation (IGF) signal after sending the ignition (IGT) signal, the ECM interprets this as a fault in the igniter and sets a DTC.

MONITOR STRATEGY


Related DTCs
P0351: Ignition coil with igniter circuit (#1) malfunction
P0352: Ignition coil with igniter circuit (#2) malfunction
P0353: Ignition coil with igniter circuit (#3) malfunction
P0354: Ignition coil with igniter circuit (#4) malfunction
Required sensors/components
Igniter
Frequency of operation
Continuous
Duration
0.256 seconds
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
None
Engine speed
1,500 rpm or less
Either of the following conditions is met:
(a) or (b)
(a) Following conditions are met:
1 & 2
1. Engine speed
500 rpm or less
2. Battery voltage
6 V or more
(b) Following conditions are met:
1 & 2
1. Engine speed
More than 500 rpm
2. Battery voltage
10 V or more

TYPICAL MALFUNCTION THRESHOLDS


Ignition signal fail count*
More than 2 times
*: Counted when the IGF signal is not returned to the ECM even though the IGT signal has been sent.

COMPONENT OPERATING RANGE


Number of IGF signals
Equals the number of IGT signals

WIRING DIAGRAM


A151901E03


INSPECTION PROCEDURE

HINT:
Read freeze frame data using Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.CHECK SPARK PLUG AND SPARK OF MISFIRING CYLINDER

OK:
Spark occurs.



NG
Go to step 4
OK


2.CHECK HARNESS AND CONNECTOR (IGNITION COIL - ECM (IGF SIGNAL TERMINAL))


    A054393E52
  1. Disconnect the I1, I2, I3 or I4 ignition coil and igniter connector.



    A065743E80
  1. Disconnect the E4 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    I1-2 (IGf) - E4-23 (IGF)
    Below 1 Ω
    I2-2 (IGf) - E4-23 (IGF)
    Below 1 Ω
    I3-2 (IGf) - E4-23 (IGF)
    Below 1 Ω
    I4-2 (IGf) - E4-23 (IGF)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    I1-2 (IGf) or E4-23 (IGF) - Body ground
    10 kΩ or higher
    I2-2 (IGf) or E4-23 (IGF) - Body ground
    10 kΩ or higher
    I3-2 (IGf) or E4-23 (IGF) - Body ground
    10 kΩ or higher
    I4-2 (IGf) or E4-23 (IGF) - Body ground
    10 kΩ or higher

  1. Reconnect the ignition coil and igniter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK ECM (IGF VOLTAGE)


    A124045E07
  1. Disconnect the I1, I2, I3 or I4 ignition coil and igniter connector.

  1. Turn the power switch ON (IG).

  1. Measure the voltage between the specified terminals of the E4 and E5 ECM connectors.

    Standard voltage:
    Tester Connection
    Specified Condition
    E4-23 (IGF) - E5-28 (E1)
    4.5 to 5.5 V

  1. Reconnect the ignition coil and igniter connector.



NG
REPLACE ECM
OK

REPLACE IGNITION COIL 

4.CHECK HARNESS AND CONNECTOR (IGNITION - ECM (IGT SIGNAL TERMINAL))


    A054393E50
  1. Disconnect the I1, I2, I3 or I4 ignition coil and igniter connector.



    A065743E76
  1. Disconnect the E4 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    I1-3 (IGt) - E4-8 (IGT1)
    Below 1 Ω
    I2-3 (IGt) - E4-9 (IGT2)
    Below 1 Ω
    I3-3 (IGt) - E4-10 (IGT3)
    Below 1 Ω
    I4-3 (IGt) - E4-11 (IGT4)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    I1-3 (IGt) or E4-8 (IGT1) - Body ground
    10 kΩ or higher
    I2-3 (IGt) or E4-9 (IGT2) - Body ground
    10 kΩ or higher
    I3-3 (IGt) or E4-10 (IGT3) - Body ground
    10 kΩ or higher
    I4-3 (IGt) or E4-11 (IGT4) - Body ground
    10 kΩ or higher

  1. Reconnect the ignition coil and igniter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK ECM (IGT1, IGT2, IGT3 OR IGT4 VOLTAGE)
A124045E08
  1. Measure the voltage between the applicable terminals of the E4 and E5 ECM connectors when the engine is cranked.

    Standard voltage:
    Tester Connection
    Specified Condition
    E4-8 (IGT1) - E5-28 (E1)
    0.1 to 4.5 V
    E4-9 (IGT2) - E5-28 (E1)
    0.1 to 4.5 V
    E4-10 (IGT3) - E5-28 (E1)
    0.1 to 4.5 V
    E4-11 (IGT4) - E5-28 ( E1)
    0.1 to 4.5 V



NG
REPLACE ECM
OK


6.CHECK ECM (IGT1, IGT2, IGT3 OR IGT4 VOLTAGE)


    A124045E08
  1. Disconnect the I1, I2, I3 or I4 ignition coil and igniter connector.

  1. Measure the voltage between the applicable terminals of the E4 and E5 ECM connectors when the engine is cranked.

    Standard voltage:
    Tester Connection
    Specified Condition
    E4-8 (IGT1) - E5-28 (E1)
    4.5 V or more
    E4-9 (IGT2) - E5-28 (E1)
    4.5 V or more
    E4-10 (IGT3) - E5-28 (E1)
    4.5 V or more
    E4-11 (IGT4) - E5-28 (E1)
    4.5 V or more

  1. Reconnect the ignition coil and igniter connector.



NG
REPLACE ECM
OK


7.CHECK IGNITION COIL (POWER SOURCE)


    A054393E53
  1. Disconnect the I1, I2, I3 or I4 ignition coil and igniter connector.

  1. Turn the power switch ON (IG).

  1. Measure the voltage between the terminals of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    I1-1 (+B) - I1-4 (GND)
    9 to 14 V
    I2-1 (+B) - I2-4 (GND)
    9 to 14 V
    I3-1 (+B) - I3-4 (GND)
    9 to 14 V
    I4-1 (+B) - I4-4 (GND)
    9 to 14 V

  1. Reconnect the ignition coil and igniter connector.



OK
REPLACE IGNITION COIL
NG


8.CHECK HARNESS AND CONNECTOR (IGNITION COIL - IG2 RELAY)


    A054393E53
  1. Disconnect the I1, I2, I3 or I4 ignition coil and igniter connector.



    A082810E02
  1. Remove the integration relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    I1-1 (+B) - 3I-4 (IG2 relay)
    Below 1 Ω
    I2-1 (+B) - 3I-4 (IG2 relay)
    Below 1 Ω
    I3-1 (+B) - 3I-4 (IG2 relay)
    Below 1 Ω
    I4-1 (+B) - 3I-4 (IG2 relay)
    Below 1 Ω
    I1-4 (GND) - Body ground
    Below 1 Ω
    I2-4 (GND) - Body ground
    Below 1 Ω
    I3-4 (GND) - Body ground
    Below 1 Ω
    I4-4 (GND) - Body ground
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    I1-1 (+B) or 3I-4 (IG2 relay) - Body ground
    10 kΩ or higher
    I2-1 (+B) or 3I-4 (IG2 relay) - Body ground
    10 kΩ or higher
    I3-1 (+B) or 3I-4 (IG2 relay) - Body ground
    10 kΩ or higher
    I4-1 (+B) - 3I-4 (IG2 relay) - Body ground
    10 kΩ or higher

  1. Reconnect the ignition coil and igniter connector.

  1. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE IGNITION COIL