SFI SYSTEM > CHECK MODE PROCEDURE |
| CHECK MODE PROCEDURE (Using Techstream) |
Check the initial conditions.
Battery positive voltage 11 V or more
Throttle valve fully closed
Shift position in the P or N
A/C switched OFF
Connect Techstream to the DLC3.
Turn the power switch ON (IG).
![]() |
Change the ECM to check mode using Techstream. Make sure the MIL flashes as shown in the illustration.
Start the HV main system (READY ON). The MIL should turn off after the system starts.
Simulate the condition of the malfunction described by the customer.
After simulating the malfunction conditions, check DTCs, freeze frame data and other data using the tester.
After checking DTCs, inspect applicable circuits.