DTC P0A4B-253 Generator Position Sensor Circuit |
DTC P0A4C-513 Generator Position Sensor Circuit Range / Performance |
DTC P0A4D-255 Generator Position Sensor Circuit Low |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A4B | 253 | Interphase short in generator resolver circuit |
|
| P0A4C | 513 | Generator resolver output is out of normal range |
|
| P0A4D | 255 | Open or short in generator resolver circuit |
|
| Related DTCs | P0A4B (INF 253): Generator position sensor circuit malfunction / Short circuit between phases P0A4C (INF 513): Generator position sensor circuit malfunction / Range check P0A4D (INF 255): Generator position sensor circuit malfunction / Circuit discontinuity or short circuit |
| Required sensor / components | Generator resolver |
| Frequency of operation | Continuous |
| Duration | TOYOTA's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TOYOTA's intellectual property |
| No other condition | - |
| Generator resolver | Circuit malfunction (interphase shot, open or short), or abnormal output |
| Generator resolver | DTCs P0A4B (INF 253) P0A4C (INF 513) and P0A4D (INF 255) are not detected |

| 1.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - GENERATOR RESOLVER) |
![]() |
Disconnect the H17 HV control ECU connector.
![]() |
Disconnect the M5 generator resolver connector.
Turn the power switch ON (IG).
Measure the voltage between the terminals of the HV control ECU connector and body ground.
| Tester Connection | Specified Condition |
| GRF (H17-27) - Body ground | Below 1 V |
| GRFG (H17-26) - Body ground | Below 1 V |
| GSN (H17-22) - Body ground | Below 1 V |
| GSNG (H17-21) - Body ground | Below 1 V |
| GCS (H17-23) - Body ground | Below 1 V |
| GCSG (H17-24) - Body ground | Below 1 V |
Turn the power switch OFF.
Measure the resistance between the wire harness side connectors.
| Tester Connection | Specified Condition |
| GRF (H17-27) - GRF (M5-3) | Below 1 Ω |
| GRFG (H17-26) - GRFG (M5-6) | Below 1 Ω |
| GSN (H17-22) - GSN (M5-2) | Below 1 Ω |
| GSNG (H17-21) - GSNG (M5-5) | Below 1 Ω |
| GCS (H17-23) - GCS (M5-1) | Below 1 Ω |
| GCSG (H17-24) - GCSG (M5-4) | Below 1 Ω |
| Tester Connection | Specified Condition |
| GRF (H17-27) or GRF (M5-3) - Body ground | 10 kΩ or higher |
| GRFG (H17-26) or GRFG (M5-6) - Body ground | 10 kΩ or higher |
| GSN (H17-22) or GSN (M5-2) - Body ground | 10 kΩ or higher |
| GSNG (H17-21) or GSNG (M5-5) - Body ground | 10 kΩ or higher |
| GCS (H17-23) or GCS (M5-1) - Body ground | 10 kΩ or higher |
| GCSG (H17-24) or GCSG (M5-4) - Body ground | 10 kΩ or higher |
Reconnect the generator resolver connector.
Reconnect the HV control ECU connector.
|
| ||||
| OK | |
| 2.INSPECT GENERATOR RESOLVER |
![]() |
Disconnect the M5 generator resolver connector.
Measure the resistance between the terminals of the generator resolver.
| Tester Connection | Specified Condition |
| GCS (M5-1) - GCSG (M5-4) | 12.6 to 16.8 Ω |
| GSN (M5-2) - GSNG (M5-5) | 12.6 to 16.8 Ω |
| GRF (M5-3) - GRFG (M5-6) | 7.65 to 10.2 Ω |
Using a megohmmeter, measure the insulation resistance between the terminals of the generator resolver.
| Tester Connection | Specified Condition |
| GCS (M5-1) - GSN (M5-2) | 10 MΩ or higher |
| GCS (M5-1) - GRF (M5-3) | 10 MΩ or higher |
| GSN (M5-2) - GRF (M5-3) | 10 MΩ or higher |
| GCSG (M5-4) - GSNG (M5-5) | 10 MΩ or higher |
| GCSG (M5-4) - GRFG (M5-6) | 10 MΩ or higher |
| GSNG (M5-5) - GRFG (M5-6) | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||