Home › HYBRID SYSTEM › P112 HYBRID BATTERY CONTROL › HYBRID BATTERY SYSTEM

HYBRID BATTERY SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



READ DATA LIST

NOTICE:
  1. The DATA LIST values may vary significantly if there are slight differences in measurement, differences in the environment in which the measurements are obtained, or the aging of the vehicle. Thus, definite standards or judgment values are unavailable. There may be a malfunction even if a measured value is within the reference range.
  2. In the event of intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions, in order to reach an overall judgment by comparing all the items of the DATA LIST.

HINT:
Using the Techstream DATA LIST allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the DATA LIST as the first step of troubleshooting is one method to shorten diagnostic time.

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch ON (IG) and the tester ON.

  3. Enter the following menus: Powertrain / HV Battery / Data List.

  4. Check the results by referring to the following table.

    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Coolant Temp
    Engine coolant temperature /
    Min.: -40°F (-40°C), Max.: 284°F (140°C)
    After warming up:
    176 to 212°F (80 to 100°C)
    1. The value is -40°F (-40°C):
      Open in sensor circuit
    2. If the value is 284°F (140°C):
      Short in sensor circuit
    Engine Rev
    Min.: 0, Max.: 16383.75
    Idling: 950 to 1050 rpm
    -
    Vehicle Spd
    Vehicle speed /
    Min.: 0 mph (0 km/h), Max.: 158.45 mph (255 km/h)
    Vehicle stopped: 0 mph (0 km/h)
    -
    Eng Run Time
    Elapsed time after starting engine /
    Min.: 0 s, Max.: 65,535 s
    -
    -
    +B
    Auxiliary battery voltage /
    Min.: 0 V, Max.: 65.535 V
    Constant:
    Auxiliary battery voltage +-3 V
    -
    DTC Clear Warm
    The number of times engine is warmed up after clearing DTCs /
    Min.: 0, Max.: 255
    MIL OFF, engine coolant temperature increases from below 72°F (22°C) before starting the engine to above 158°F (70°C) after starting the engine:
    Increases once
    -
    DTC Clear Run
    Drive distance after clearing DTCs /
    Min.: 0 km, Max.: 65,535 km
    -
    -
    DTC Clear Min
    Elapsed time after clearing DTCs /
    Min.: 0 min, Max.: 65,535 min
    -
    -
    MIL on Eng Time
    Drive distance after malfunction occurrence /
    Min.: 0 km, Max.: 65,535 km
    -
    -
    MIL status
    MIL status/
    ON or OFF
    MIL ON: ON
    Constant ON:
    Repair in accordance with detected DTCs
    Driving Mileage
    Accumulated driving mileage after the malfunction occurrence/
    Min.: 0 km, Max.: 65,535 km
    -
    -
    Battery SOC
    Battery state of charge/
    Min.: 0%, Max: 100%
    Always: 0 to 100%
    -
    (Delta SOC
    Difference between maximum and minimum values of SOC/
    Min.: 0%, Max.: 100%
    READY light ON, engine stopped and no electrical load:
    0 to 60%
    -
    IB Battery
    Current value of battery pack/
    Min.: -327.68 A, Max.: 327.67 A
    1. Soon after a full-load acceleration with the engine stopped:
      Maximum 140 A (room temperature)
    2. When shifting into N position, 1 second has elapsed after engine started with P position, engine stopped, head light ON, A/C fan high, and READY light ON:
      Maximum 30 A
    -
    Batt Inside Air
    Temperature of intake ambient air to battery pack/
    Min.: -327.68°C, Max.: 327.67°C
    Undisturbed for 1 day:
    Same as ambient air temperature
    -
    VMF Fan Voltage
    Battery blower motor monitoring voltage/
    Min.: -25.6 V, Max.: 25.4 V
    Fan mode 1 with READY light ON and P position:
    9.5 to 11.5 V
    -
    Aux. Batt V
    Auxiliary battery voltage/
    Min.: 0 V, Max.: 25.4 V
    Equivalent to auxiliary battery voltage
    -
    WIN
    Charge control wattage which is sent from battery ECU to hybrid vehicle control ECU/
    Min.: -64 kW, Max.: 0 kW
    -25 kW or more
    -
    WOUT
    Discharge control wattage which is sent from battery ECU to hybrid vehicle control ECU/
    Min.: 0 kW, Max.: 63.5 kW
    21 kW or less
    -
    Cooling Fan Spd
    Battery blower motor actuation mode/
    Min.: 0, Max.: 6
    Stopped: 0
    Low to high speed actuation: 1 to 6
    -
    ECU Ctrl Mode
    ECU control mode/
    Min.: 0, Max.: 4
    -
    -
    CCTL Sig
    -
    -
    -
    EQCO Relay Sig
    -
    -
    -
    EQTR Charge Sig
    -
    -
    -
    SBLW Rqst
    Battery blower motor stop control request (standby blower)
    ON/OFF
    -
    Batt Temp 1 to 3
    Temperature of HV battery/
    Min.: -327.68°C, Max.: 327.67°C
    Undisturbed for 1 day:
    Same as ambient air temperature
    -
    Num Of Batt
    The number of battery blocks/
    Min.: 0, Max.: 255
    Always: 14
    -
    Bat Block Min V
    Battery block minimum voltage/
    Min.: -327.68 V, Max.: 327.67 V
    SOC 50 to 60%: 12 V or more
    -
    Min Bat Block #
    Battery block number with minimum voltage
    One of numbers 0 to 13
    -
    Bat Block Max V
    Battery block maximum voltage/
    Min.: -327.68 V, Max.: 327.67 V
    SOC 55 to 60%: 23 V or less
    -
    Max Bat Block #
    Battery block number with maximum voltage
    One of numbers 0 to 13
    -
    V1 to V14 Batt Block
    Battery block voltage/
    Min.: -327.68 V, Max.: 327.67 V
    SOC 60%: 12 to 20 V
    -
    IR01 to 14
    Internal resistance of each battery block/
    Min.: 0 Ω, Max.: 0.255 Ω
    Always: 0.01 to 0.1 Ω
    -
    BLOW TIME
    Battery low time/
    Min.: 0 km, Max.: 65,535
    Always: Cumulative number of times
    -
    DCIH TIME
    DC inhibit time/
    Min.: 0 km, Max.: 65,535
    Always: Cumulative number of times
    -
    BHI TIME
    Battery to high time/
    Min.: 0 km, Max.: 65,535
    Always: Cumulative number of times
    -
    HTMP TIME
    High temperature time/
    Min.: 0 km, Max.: 65,535
    Always: Cumulative number of times
    -
    Regulation
    Compliance regulation
    OBD
    -
    #Codes
    The number of emission related powertrain DTCs/
    Min.: 0, Max.: 127
    -
    -
    DTC
    The number of stored DTCs/
    Min.: 0, Max.: 255
    -
    -
    Calc Load
    Calculate load/
    Min.: 0%, Max: 100%
    1. Idling (INSPECTION MODE): 10 to 20%
    2. Running without load (1,500rpm): 10 to 20%
    -
    Throttle Position
    Min.: 0%, Max.: 100%
    1. Throttle valve fully closed: 10 to 24%
    2. Throttle valve fully open: 64 to 96%
    -


PERFORM ACTIVE TEST

NOTICE:
Beware that if the connector to the Techstream becomes disconnected or a communication error occurs during the ACTIVE TEST, the vehicle could become inoperative (READY light OFF).

HINT:
Performing an ACTIVE TEST using the Techstream enables components including the relay, VSV, and actuator, to be operated without removing any parts. Performing an ACTIVE TEST as the first step of troubleshooting is one method to shorten diagnostic time.
It is possible to display items in the DATA LIST during the ACTIVE TEST.

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch ON (IG) and the tester ON.

  3. Enter the following menus: Powertrain / HV Battery / Active Test..

  4. Perform the ACTIVE TEST according to the display on the tester.


Tester Display
Test Part
Control Range
Test Condition
Cooling Fan Spd
To check the operation and the speed of the battery blower motor
Stops the battery blower motor in mode 0 or operates it in modes 1 to 6
Disabled when a DTC is detected