Home › ENGINE › 1NZ-FXE ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P1115    Coolant Temperature Sensor Circuit for Coolant Heat Storage System

DTC    P1117    Coolant Temperature Sensor Circuit Low for Coolant Heat Storage

DTC    P1118    Coolant Temperature Sensor Circuit High for Coolant Heat Storage

for Preparation Click here


DESCRIPTION

HINT:
Although each DTC title says "Coolant Temperature Sensor", these DTCs are related to the coolant heat storage tank outlet temperature sensor.


A082803E01

This system uses an electric pump to supply hot coolant stored in the coolant heat storage tank into the cylinder head of the engine, in order to optimize engine starting combustion and reduce the amount of unburned gas that is discharged while the engine is started. Before the engine starts, the ECM operates the electric water pump to direct the hot coolant in the heat storage tank into the engine, in order to heat the cylinder head (this process is called "preheat mode"). The duration of the operation of the electric water pump is variable, depending on the temperature of the cylinder head. During the normal operation of the engine, the water valve opens the passage between the cylinder head and the heater and closes the passage between the cylinder head and the tank. During preheat mode in which the cylinder head is heated, the water valve opens the passage between the tank and the cylinder head, in order to allow the coolant to flow from the tank to the cylinder head. At this time, in order to warm up the intake port quickly before the engine is started, the coolant flows in the reverse direction.
The sensor for the system, which is provided at the tank outlet, is constructed similarly to the engine coolant temperature sensor and is connected to the ECM. The CHS tank outlet temperature sensor has a built in thermistor, whose resistance varies with the coolant temperature.

HINT:
If the ECM detects DTC P0115, P0117 or P0118, it operates the fail-safe function in which the engine coolant temperature is assumed to be 80°C (176°F).


DTC No.
DTC Detection Condition
Trouble Area
P1115
Open or short in CHS tank outlet temperature sensor circuit for 0.5 seconds
  1. Open or short in CHS tank outlet temperature sensor circuit
  2. CHS tank outlet temperature sensor
  3. ECM
P1117
Short in CHS tank outlet temperature sensor circuit
  1. Short in CHS tank outlet temperature sensor circuit
  2. CHS tank outlet temperature sensor
  3. ECM
P1118
Open in CHS tank outlet temperature sensor circuit
  1. Open in CHS tank outlet temperature sensor circuit
  2. CHS tank outlet temperature sensor
  3. ECM

MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to control the coolant heat storage (CHS) system properly. If the sensor output voltage deviates from the normal operating range, the ECM determines that the CHS tank outlet temperature sensor circuit has malfunctioned, and outputs a DTC.
Example:
A sensor output voltage of -40°C (-40°F) or 140°C (284°F) is determined as a malfunction.

MONITOR STRATEGY


Related DTCs
P1115: Coolant temperature sensor circuit for coolant heat storage system
P1117: Coolant temperature sensor circuit low for coolant heat storage system
P1118: Coolant temperature sensor circuit high for coolant heat storage system
Required sensors/components
Coolant heat storage tank outlet temperature sensor
Frequency of operation
Continuous
Duration
0.5 seconds
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
None

TYPICAL MALFUNCTION THRESHOLDS


P1115: 
Sensor voltage (coolant temperature at CHS tank outlet)
Less than 0.14 V or more than 4.91 V
(more than 140°C (284°F) or -40°C (-40°F) or less)

P1117: 
Sensor voltage (coolant temperature at CHS tank outlet)
Less than 0.14 V
(more than 140°C (284°F))

P1118: 
Sensor voltage (coolant temperature at CHS tank outlet)
More than 4.19 V
(-40°C (-40°F) or less)

COMPONENT OPERATING RANGE


Sensor resistance
79 Ω (140°C (284°F)) to 156 kΩ (-40°C (-40°F))

WIRING DIAGRAM


A151887E04


INSPECTION PROCEDURE

CAUTION:
Be careful when replacing any part in the system or changing the coolant because the coolant in the heat storage tank is hot even if the engine is cold.

HINT:
  1. If different DTCs related to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
  2. To check the coolant heat storage (CHS) system, the ECM may cause the water pump of the CHS system to operate 5 hours after the power switch has been turned OFF.
  3. Read freeze frame data using Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air/fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.

1.READ VALUE OF TECHSTREAM
  1. Connect Techstream to the DLC3.

  1. Turn the power switch ON (IG) and turn Techstream ON.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Code.

  1. Read the DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    P1115
    A
    P1117
    B
    P1118
    B



B
Go to step 3
A


2.CHECK ECM (THW2 - E2 VOLTAGE)


    A124045E09
  1. Turn the power switch ON (IG).

  1. Measure the voltage between terminals THW2 and E2 of the ECM E4 and E7 connectors.

    Standard voltage:
    Water Temperature °C (°F)
    Voltage
    20 (68)
    0.5 to 3.4 V
    60 (140)
    0.2 to 1.0 V



OK
CHECK FOR INTERMITTENT PROBLEMS
NG


3.CHECK HARNESS AND CONNECTOR (CHS TANK OUTLET TEMPERATURE SENSOR - ECM)


  1. Check the harness and the connectors between the coolant heat storage tank outlet temperature sensor and the ECM connectors.



      A082813E02
    1. Disconnect the C19 coolant heat storage tank outlet temperature sensor connector.



    2. A082814E01
    3. Disconnect the E4 and E7 ECM connectors.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for open):
      Tester Connection
      Specified Condition
      C19-2 (CHS temperature sensor) - E7-33 (THW2)
      Below 1 Ω
      C19-1 (CHS temperature sensor) - E4-28 (E2)
      Below 1 Ω

      Standard resistance (Check for short):
      Tester Connection
      Specified Condition
      C19-2 (CHS temperature sensor) or E7-33 (THW2) - Body ground
      10 kΩ or higher

    5. Reconnect the coolant heat storage tank outlet temperature sensor connector.

    6. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.INSPECT TEMPERATURE SENSOR (CHS TANK OUTLET TEMPERATURE SENSOR)


    A081700E08
  1. Remove the coolant heat storage (CHS) tank outlet temperature sensor.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    2 to 3 kΩ at 20°C (68°F)
    1 - 2
    0.2 to 0.4 kΩ at 80°C (176°F)

    NOTICE:
    In case of checking the CHS tank outlet temperature sensor in water, be careful not to allow water to contact the terminals. After checking, dry the sensor.

    HINT:
    Alternative procedure: Connect an ohmmeter to the installed CHS tank outlet temperature sensor and read the resistance. Use an infrared thermometer to measure the CHS tank outlet temperature in the immediate vicinity of the sensor. Compare these values to the resistance/temperature graph. Change the engine temperature (warm up or allow to cool down) and repeat the test.

  1. Reinstall the coolant heat storage tank outlet temperature sensor.



NG
REPLACE TEMPERATURE SENSOR
OK

REPLACE ECM