Home › HYBRID SYSTEM › P112 HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A94-554    DC / DC Converter Performance

DTC    P0A94-555    DC / DC Converter Performance

DTC    P0A94-556    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

See the description of the boost converter .
If the boost converter has a circuit malfunction, internal short, or overheats, the boost converter transmits that information to the FCV terminal of the HV control ECU via the boost converter fail signal line.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
554
Boost converter fail (FCV) signal detection (over current by HV control ECU malfunction)
  1. Wire harness or connector
  2. HV transaxle assembly
  3. Hybrid vehicle motor
  4. Hybrid vehicle generator
  5. HV control ECU
  6. Inverter with converter assembly
P0A94
555
Boost converter fail (FCV) signal detection (over current by inverter assembly malfunction)
  1. Wire harness or connector
  2. HV transaxle assembly
  3. Hybrid vehicle motor
  4. Hybrid vehicle generator
  5. HV control ECU
  6. Inverter with converter assembly
P0A94
556
Boost converter fail (FCV) signal detection (over current by HV transaxle assembly malfunction)
  1. Wire harness or connector
  2. HV transaxle assembly
  3. Hybrid vehicle motor
  4. Hybrid vehicle generator
  5. HV control ECU
  6. Inverter with converter assembly

MONITOR DESCRIPTION

If over-amperage flows through the boost converter due to an internal short, the boost converter transmits a boost converter fail signal to the HV control ECU. Upon receiving this signal, the HV control ECU illuminates the MIL and sets a DTC.

MONITOR STRATEGY


Related DTCs
P0A94 (INF 554 / 555 / 556):
FCV detection over current
Required sensor / components
Boost converter
Frequency of operation
Continuous
Duration
TOYOTA's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TOYOTA's intellectual property
Other conditions belong to TOYOTA's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


Boost converter
Over current (internal short)

COMPONENT OPERATING RANGE


Boost converter
DTC P0A94 (INF 554 / 555 / 556) is not detected

WIRING DIAGRAM

Refer to DTC P0A78 (INF 279) .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are servicing the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:
At least 5 minutes are required to discharge the high-voltage condenser inside the inverter.

1.READ OUTPUT DTC (HV ECU)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    DTCs listed in the table below are output


    DTC No.
    Relevant Diagnosis
    P0A1D
    Hybrid Powertrain Control Module
    P0A2B, P0A2C or P0A2D
    Drive Motor "A" Temperature Sensor Circuit System
    P0A37, P0A38 or P0A39
    Generator Temperature Sensor Circuit System
    P0A3F, P0A40 or P0A4
    Drive Motor "A" Position Sensor Circuit System
    P0A4B, P0A4C or P0A4D
    Generator Position Sensor Circuit System
    P0A60 or P0A63
    Drive Motor "A" Current Sensor Circuit System
    P0A72 or P0A75
    Generator Current Sensor Circuit System
    P0A78
    Drive Motor "A" Inverter Performance
    P0A7A
    Generator Inverter Performance
    P0A90
    Drive Motor "A" Performance
    P0A92
    Hybrid Generator Performance
    P0A93
    Inverter Cooling System Malfunction
    P0A94
    DC / DC Converter Malfunction
    P0AA1, P0AA4, P0AE0, P0AE6, P0AE7, P0ADB or P0ADF
    System Main Relay Circuit System
    P0AA6, P3004
    High Voltage System
    P0AEE
    Motor Inverter Temperature Sensor Malfunction
    P3000
    HV Battery System Malfunction
    P3110
    Integration Relay Malfunction
    P3221
    Generator Inverter Temperature Sensor Circuit System
    P3226
    DC / DC Boost Converter Temperature Sensor Circuit System



YES
GO TO DTC CHART. FIND PAGE NUMBER TO PROCEED TO DIAGNOSTIC TROUBLESHOOTING FLOWCHART.
NO


2.CHECK CONNECTION CONDITION OF HYBRID VEHICLE CONTROL ECU CONNECTOR (LOOSENESS AND POOR CONTACT)


    A093719E09
  1. Check the connection condition of all the connectors at the HV control ECU.

    OK:
    Connectors have been connected securely and there is no poor connection.



NG
CONNECT SECURELY
OK


3.CHECK CONNECTION CONDITION OF INVERTER CONNECTOR (LOOSENESS AND POOR CONTACT)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Turn the power switch OFF.

  1. Remove the service plug grip .

    NOTICE:
    Turning the power switch ON (READY) with the service plug grip removed could cause malfunction. Therefore, never turn the power switch ON (READY) in this state.

  1. Remove the inverter cover .



    A092044E02
  1. Check the connection condition of the I9 and I10 inverter connectors.

    OK:
    Connectors have been connected securely and there is no poor connection.



NG
CONNECT SECURELY
OK


4.CONFIRM INFORMATION (EXCLUSIVE INFO 4)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Select DTC P0A94 to display its freeze frame data.

  1. Select the item that has INF code 554, 555, or 556 from among "Detail Code 1 to 5, Detail Information 1 to 5" and press ENTER.

  1. Read "Exclusive Information 4".

    Result:

    Displayed in Exclusive Information 4
    Proceed to
    -127 to -120, -95 to -88, -63 to -56, -31 to -24, 1 to 8, 33 to 40, 65 to 72, 97 to 104
    A
    -119 to -112, -87 to -80, -55 to -48, -23 to -16, 9 to 16, 41 to 48, 73 to 80, 105 to 112
    B
    -111 to -104, -79 to -72, -47 to -40, -15 to -8, 17 to 24, 49 to 56, 81 to 88, 113 to 120
    C
    -103 to -96, -71 to -64, -39 to -32, -7 to 0, 25 to 32, 57 to 64, 89 to 96, 121 to 127
    D



B
REPLACE HYBRID VEHICLE CONTROL ECU

C
REPLACE INVERTER WITH CONVERTER ASSEMBLY

D
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
A


5.INSPECT HYBRID VEHICLE MOTOR ASSEMBLY

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Turn the power switch OFF.

  1. Remove the service plug grip .

    NOTICE:
    Turning the power switch ON (READY) with the service plug grip removed could cause malfunction. Therefore, never turn the power switch ON (READY) in this state.

  1. Remove the inverter cover .



    A092045E03
  1. Disconnect the three-phase alternating current cable for the hybrid vehicle motor from the inverter.

  1. Using a milliohm meter, measure the resistance between the three-phase alternating current cable terminals of the hybrid vehicle motor.

    NOTICE:
    If the motor temperature is too high, the resistance varies considerably, which hinders determining malfunction. Therefore, measure the resistance at a minimum 8 hours after the vehicle has been stopped.

    Standard resistance:
    Tester Connection
    Specified Condition*
    U (I14-1) - V (I14-2)
    Below 135 mΩ at 68°F (20°C)
    V (I14-2) - W (I14-3)
    Below 135 mΩ at 68°F (20°C)
    W (I14-3) - U (I14-1)
    Below 135 mΩ at 68°F (20°C)

    1. *: Apply the formula given below to correct the resistance.
      R20 = Rt / {1 + 0.00393 x (T - 20)}
      R20: Resistance converted to 68°F (20°C) (mΩ)
      Rt: Resistance between measured lines (mΩ)
      T: Ambient air temperature during measurement (°C)

  1. Calculate the difference between the maximum and minimum resistance between terminals U - V, V - W, and W - U.

    Standard resistance:
    Below 2 mΩ

  1. Using a megohmmeter, measure the insulation resistance between the three-phase alternating current cable terminals of the hybrid vehicle motor and the body ground.

    Standard resistance:
    Tester Connection
    Specified Condition
    U (I14-1) - Body ground
    10 MΩ or higher
    V (I14-2) - Body ground
    10 MΩ or higher
    W (I14-3) - Body ground
    10 MΩ or higher

  1. Reconnect the three-phase alternating current cable for the hybrid vehicle motor.



NG
REPLACE HYBRID VEHICLE MOTOR ASSEMBLY
OK


6.INSPECT HYBRID VEHICLE GENERATOR ASSEMBLY

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Check that the service plug grip and inverter cover have been removed.



    A092046E03
  1. Disconnect the three-phase alternating current cable for the hybrid vehicle generator from the inverter.

  1. Using a milliohm meter, measure the resistance between the three-phase alternating current cable terminals of the hybrid vehicle generator.

    NOTICE:
    If the generator temperature is too high, the resistance varies considerably, which hinders determining malfunction. Therefore, measure the resistance at a minimum 8 hours after the vehicle has been stopped.

    Standard resistance:
    Tester Connection
    Specified Condition*
    U (I15-1) - V (I15-2)
    Below 109 mΩ at 68°F (20°C)
    V (I15-2) - W (I15-3)
    Below 109 mΩ at 68°F (20°C)
    W (I15-3) - U (I15-1)
    Below 109 mΩ at 68°F (20°C)

    1. *: Apply the formula given below to correct the resistance.
      R20 = Rt / {1 + 0.00393 x (T - 20)}
      R20: Resistance converted to 68°F (20°C) (mΩ)
      Rt: Resistance between measured lines (mΩ)
      T: Ambient air temperature during measurement (°C)

  1. Calculate the difference between the maximum and minimum resistance between terminals U - V, V - W, and W - U.

    Standard resistance:
    Below 2 mΩ

  1. Using a megohmmeter, measure the insulation resistance between the three-phase alternating current cable terminals of the hybrid vehicle generator and the body ground.

    Standard resistance:
    Tester Connection
    Specified Condition
    U (I15-1) - Body ground
    10 MΩor higher
    V (I15-2) - Body ground
    10 MΩor higher
    W (I15-3) - Body ground
    10 MΩor higher

  1. Reconnect the three-phase alternating current cable for the hybrid vehicle generator.



NG
REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY
OK


7.PERFORM ACTIVE TEST BY THE TECHSTREAM (FORCIBLE STOP OF INVERTER DRIVE)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Check that the service plug grip and inverter cover have been removed.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test.



    A093730E07
  1. Measure the voltage between the terminals of the inverter connector while effecting "Forcible Stop of Inverter Drive".

    Standard voltage:
    Tester Connection
    Specified Condition
    MUU (I10-9) - GINV (I10-16)
    12 to 16 V
    MVU (I10-10) - GINV (I10-16)
    12 to 16 V
    MWU (I10-11) - GINV (I10-16)
    12 to 16 V
    GUU (I10-4) - GINV (I10-16)
    12 to 16 V
    GVU (I10-5) - GINV (I10-16)
    12 to 16 V
    GWU (I10-6) - GINV (I10-16)
    12 to 16 V

  1. Turn the power switch OFF.



OK
REPLACE INVERTER WITH CONVERTER ASSEMBLY
NG


8.PERFORM ACTIVE TEST BY THE TECHSTREAM (FORCIBLE STOP OF INVERTER DRIVE)

CAUTION:
Wear insulated gloves before performing the following operation.

  1. Check that the service plug grip and inverter cover have been removed.



    A093731E05
  1. Disconnect the I10 inverter connector.

  1. Connect the Techstream to the DLC3.

  1. Turn the power switch ON (IG).

    HINT:
    DTCs for the interlock switch system are output when turning the power switch ON (IG) with both service plug grip and inverter cover removed.

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test.

  1. Measure the voltage between the terminals of the inverter connector while effecting "Forcible Stop of Inverter Drive".

    Standard voltage:
    Tester Connection
    Specified Condition
    MUU (I10-9) - GINV (I10-16)
    14 to 16 V
    MVU (I10-10) - GINV (I10-16)
    14 to 16 V
    MWU (I10-11) - GINV (I10-16)
    14 to 16 V
    GUU (I10-4) - GINV (I10-16)
    14 to 16 V
    GVU (I10-5) - GINV (I10-16)
    14 to 16 V
    GWU (I10-6) - GINV (I10-16)
    14 to 16 V

  1. Turn the power switch OFF.

  1. Reconnect the inverter connector.

  1. Reinstall the inverter cover .

  1. Reinstall the service plug grip .



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY
OK

REPLACE HYBRID VEHICLE CONTROL ECU